keyword=End_of_Run_4377
****************************
Run Number: 4377
End of Run Comment:
Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.1923,beam_raster=off,leftarm_p=1.007,leftarm_theta=12.5,leftarm_colli=out,bbarm_i=390,bbarm_theta=48,bbarm_colli=out,comment_text=Production Kinematic E
PRESCALE FACTORS:ps1=43900 ps2=78000 ps3=4500 ps4=130 ps5=1 ps6=1 ps7=3700 ps8=100
EVENTS : [0]: 1005438 [+]: 495751 [-]: 494916
TIME : [0]: 7.749 mins [+]: 3.850 mins [-]: 3.851 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.54060 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 19.29% [+]: 20.07% [-]: 19.91%
TRIGGER RATES: PRES/REAL
T1[0] : 9.9/435693.0 Hz T2[0] : 9.8/765602.1 Hz T3[0] :10.1/45289.0 Hz T4[0] : 9.9/1286.6 Hz T5[0] :1604.0/1604.0 Hz T6[0] :2620.8/2620.8 Hz T7[0] :10.1/37415.2 Hz T8[0] :10.2/1024.0 Hz
T1[+] : 9.9/435991.0 Hz T2[+] : 9.8/766227.2 Hz T3[+] :10.1/45316.8 Hz T4[+] : 9.9/1290.3 Hz T5[+] :1607.8/1607.8 Hz T6[+] :2626.0/2626.0 Hz T7[+] :10.1/37441.5 Hz T8[+] :10.2/1024.0 Hz
T1[-] : 9.9/435292.6 Hz T2[-] : 9.8/764884.0 Hz T3[-] :10.1/45258.8 Hz T4[-] : 9.9/1282.6 Hz T5[-] :1600.0/1600.0 Hz T6[-] :2615.6/2615.6 Hz T7[-] :10.1/37388.8 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 4614/202563624 T2[0] : 4563/355945896 T3[0] : 4679/21055908 T4[0] : 4601/598170 T5[0] : 745752/745752 T6[0] :1218464/1218464 T7[0] : 4701/17395183 T8[0] : 4760/476081
T1[+] : 2294/100719452 T2[+] : 2269/177008220 T3[+] : 2326/10468749 T4[+] : 2292/298079 T5[+] : 371423/371423 T6[+] : 606647/606647 T7[+] : 2337/8649470 T8[+] : 2365/236557
T1[-] : 2291/100577669 T2[-] : 2265/176732285 T3[-] : 2323/10457380 T4[-] : 2279/296343 T5[-] : 369695/369695 T6[-] : 604350/604350 T7[-] : 2334/8638971 T8[-] : 2366/236603
AVERAGE CURRENT
BCM x1 : 2.9257 uA BCM x3 : 2.9321 uA BCM x10: 2.9573 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 583.9 ppm BCM u3 : 671.6 ppm BCM u10: 704.7 ppm
BCM d1 : 583.4 ppm BCM d3 : 657.4 ppm BCM d10: 702.3 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.001353 BCM u3 [0]:0.001355 BCM u10[0]:0.001366
BCM u1 [+]:0.0006726 BCM u3 [+]:0.0006738 BCM u10[+]:0.0006793
BCM u1 [-]:0.0006719 BCM u3 [-]:0.0006731 BCM u10[-]:0.0006784
BCM d1 [0]:0.001368 BCM d3 [0]:0.001371 BCM d10[0]:0.001384
BCM d1 [+]:0.0006799 BCM d3 [+]:0.0006817 BCM d10[+]:0.000688
BCM d1 [-]:0.0006792 BCM d3 [-]:0.0006809 BCM d10[-]:0.0006872
****************************
End-of-run EPICS data for Run Number 4377 at Tue Apr 29 09:43:56 EDT 2008
Wien angle : -40.2035
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 1.00698
Left Arm arm angle : 12.4507
Right Arm D1 momentum : 0.459612
Right Arm arm angle : 104.998
HALLA:p : 1192.38
HALLA:dpp : -5.9008e-06
Tiefenbach Hall A energy : 1192.38
Left Arm Top VDC Current : 0
Left Arm Bottom VDC Current : -4.73633
-----
Left Arm Q1 momentum : 1.00704
Left Arm Q1 power supply : 757.679
Left Arm Q1 gauss meter : -0.06395
Left Arm Q2 gauss meter : 0.1715
Left Arm Q2 power supply current : 433.604
Left Arm Q2 momentum : 1.00698
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 334.434
Left Arm D1 momentum : 1.00698
Left Arm D1 NMR : 0.372841
Left Arm Q3 gauss meter : -0.2035
Left Arm Q3 power supply current : 400.813
Left Arm Q3 momentum : 1.00677
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.459677
Right Arm Q1 power supply : 345.594
Right Arm Q1 gauss meter : -0.008735
Right Arm Q2 power supply current : 197.776
Right Arm Q2 momentum : 0.459551
Right Arm Q2 gauss meter : 0.10406
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 158.186
Right Arm D1 momentum : 0.459612
Right Arm D1 NMR : 0.170556
Right Arm Q3 power supply current : 182.885
Right Arm Q3 momentum : 0.459616
Right Arm Q3 gauss meter : 0.08185
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 390
BigBite magnet current readback : 388.1
BigBite Gaussmeter readback : -0.3177
-----
Average current of the two cavities : 2.93265
Current on Unser monitor : 14.1607
Current on Upstream bcm : 2.8855
Current on Downstream bcm : 2.97981
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 80.352
Hall C Current : 78.81
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
Hall A momentum orbit correction (dpp) : -3.02394e-06
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.38
Hall C energy (hallc_MeV) : 5713.91
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00396356
IPM1H04A.XPOS : -0.795939
IPM1H04A.YPOS : 0.783815
IPM1H04B.XPOS : -1.2875
IPM1H04B.YPOS : 1.72493
-----
Left Arm Collimator : 0.871191
HacL_HPE1313A:0_Ch58 : -0.248535
HacL_HPE1313A:0_Ch55 : 24.2188
HacL_HPE1313A:0_Ch54 : 0.174805
-----
Right Arm Collimator : -0.00888672
HacR_HPE1313A:0_Ch58 : -0.575195
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.833496
-----
Wien angle : -40.2035
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -934.12
Wien field : 26.736
Laser attenuation Hall A : 95
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.41491
SLI vert. size mm : 0
SLI y position : 2.38122
-----
Target : L1 6cm
fan frequency loop 1 : 31.5
fan frequency loop 2 : 15
Encoder position : 3.13948e+07
Target type : 3.13948e+07
temperature loop 1(1) : 20
temperature loop 1(2) : 20
temperature loop 1(3) : 20.3
Heat exchange LH : 22.4
temperature loop 2(1) : 23.53
temperature loop 2(2) : 92.07
temperature loop 2(3) : 119.99
Heat exchange H2 : 22.4
Heat exchange D2 : 24
HPH H2 loop 1 : 35.3235
HPH D2 loop 2 : 34.3025
-----