    Log entry time 10:04:12 on April 29, 2008

    Entry number 235775

    keyword=End_of_Run_4379
    ****************************
     Run Number: 4379
     End of Run Comment:
    Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.1923,beam_raster=off,leftarm_p=1.007,leftarm_theta=12.5,leftarm_colli=out,bbarm_i=390,bbarm_theta=48,bbarm_colli=out,comment_text=Production Kinematic E
     
    
    PRESCALE FACTORS:ps1=43900   ps2=78000   ps3=4500   ps4=130   ps5=1   ps6=1   ps7=3700   ps8=100   
    
    EVENTS   : [0]: 1003377      [+]: 494027       [-]: 494462       
    TIME     : [0]: 9.132 mins  [+]: 4.531 mins  [-]: 4.533 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.59048 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  18.86%      [+]:  19.55%      [-]:  19.57%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 8.5/370993.1 Hz   T2[0] : 8.4/654433.4 Hz   T3[0] : 8.6/38587.5 Hz   T4[0] : 8.4/1096.5 Hz   T5[0] :1345.7/1345.7 Hz   T6[0] :2205.2/2205.2 Hz   T7[0] : 8.6/31870.3 Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] : 8.5/371718.8 Hz   T2[+] : 8.4/655731.2 Hz   T3[+] : 8.6/38673.7 Hz   T4[+] : 8.4/1096.7 Hz   T5[+] :1347.4/1347.4 Hz   T6[+] :2207.2/2207.2 Hz   T7[+] : 8.6/31940.2 Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] : 8.5/371177.9 Hz   T2[-] : 8.4/654779.9 Hz   T3[-] : 8.6/38596.2 Hz   T4[-] : 8.5/1099.3 Hz   T5[-] :1346.8/1346.8 Hz   T6[-] :2208.9/2208.9 Hz   T7[-] : 8.6/31878.9 Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   4630/203271997  T2[0] :   4597/358572620  T3[0] :   4698/21142617  T4[0] :   4621/600783   T5[0] : 737308/737308   T6[0] :1208269/1208269  T7[0] :   4719/17462142  T8[0] :   5610/561063   
    T1[+] :   2301/101051236  T2[+] :   2285/178259638  T3[+] :   2336/10513396  T4[+] :   2293/298142   T5[+] : 366277/366277   T6[+] : 600023/600023   T7[+] :   2346/8682900  T8[+] :   2783/278373   
    T1[-] :   2299/100943342  T2[-] :   2282/178070076  T3[-] :   2332/10496384  T4[-] :   2299/298955   T5[-] : 366258/366258   T6[-] : 600732/600732   T7[-] :   2343/8669591  T8[-] :   2784/278481   
    
    AVERAGE CURRENT
    BCM x1 : 2.4996 uA  BCM x3 : 2.5055 uA  BCM x10: 2.5272 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    650.6 ppm     BCM u3 :    738.6 ppm     BCM u10:    778.4 ppm     
    BCM d1 :    655.3 ppm     BCM d3 :    728.4 ppm     BCM d10:    778.9 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001362       BCM u3 [0]:0.001365       BCM u10[0]:0.001376       
    BCM u1 [+]:0.0006771      BCM u3 [+]:0.0006785      BCM u10[+]:0.000684       
    BCM u1 [-]:0.0006765      BCM u3 [-]:0.0006777      BCM u10[-]:0.0006832      
    
    BCM d1 [0]:0.001377       BCM d3 [0]:0.001381       BCM d10[0]:0.001394       
    BCM d1 [+]:0.0006846      BCM d3 [+]:0.0006865      BCM d10[+]:0.0006929      
    BCM d1 [-]:0.0006839      BCM d3 [-]:0.0006858      BCM d10[-]:0.0006921      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4379 at Tue Apr 29 10:04:08 EDT 2008
    
    Wien angle : -40.2035
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 1.00698
    Left Arm arm angle : 12.4507
    Right Arm D1 momentum : 0.459611
    Right Arm arm angle : 104.998
    HALLA:p : 1192.38
    HALLA:dpp : -6.22295e-07
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : 1.07422
    Left Arm Bottom VDC Current : -1.26953
    -----
    Left Arm Q1 momentum : 1.00711
    Left Arm Q1 power supply : 757.679
    Left Arm Q1 gauss meter : -0.06395
    Left Arm Q2 gauss meter : 0.17149
    Left Arm Q2 power supply current : 433.604
    Left Arm Q2 momentum : 1.00698
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 334.434
    Left Arm D1 momentum : 1.00698
    Left Arm D1 NMR : 0.372841
    Left Arm Q3 gauss meter : -0.2035
    Left Arm Q3 power supply current : 400.819
    Left Arm Q3 momentum : 1.00678
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.459677
    Right Arm Q1 power supply : 345.647
    Right Arm Q1 gauss meter : -0.00874
    Right Arm Q2 power supply current : 197.778
    Right Arm Q2 momentum : 0.459557
    Right Arm Q2 gauss meter : 0.10407
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 158.187
    Right Arm D1 momentum : 0.459611
    Right Arm D1 NMR : 0.170557
    Right Arm Q3 power supply current : 182.887
    Right Arm Q3 momentum : 0.459621
    Right Arm Q3 gauss meter : 0.08185
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 390
    BigBite magnet current readback : 388.1
    BigBite Gaussmeter readback : -0.3178
    -----
    Average current of the two cavities : 2.96006
    Current on Unser monitor : 14.6251
    Current on Upstream bcm : 2.92477
    Current on Downstream bcm : 2.99534
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 79.9092
    Hall C Current : 79.26
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : -6.22295e-07
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5713.85
    Delta(E)/E width (MV_AI_DXWID) : 0.368022
    IPM1C12.XPOS : 0.000641406
    IPM1H04A.XPOS : -0.798815
    IPM1H04A.YPOS : 0.772373
    IPM1H04B.XPOS : -1.30669
    IPM1H04B.YPOS : 1.70044
    -----
    Left Arm Collimator : 0.871289
    HacL_HPE1313A:0_Ch58 : -0.249023
    HacL_HPE1313A:0_Ch55 : 24.1699
    HacL_HPE1313A:0_Ch54 : 0.173828
    -----
    Right Arm Collimator : -0.00849609
    HacR_HPE1313A:0_Ch58 : -0.574707
    HacR_HPE1313A:0_Ch55 : 22.6562
    HacR_HPE1313A:0_Ch54 : -0.833008
    -----
    Wien angle : -40.2035
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -934.12
    Wien field : 26.736
    Laser attenuation Hall A : 97
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.41491
    SLI vert. size mm : 0
    SLI y position : 2.38873
    -----
    Target : L1 6cm
    fan frequency loop 1 : 31.5
    fan frequency loop 2 : 17.5
    Encoder position : 3.13948e+07
    Target type : 3.13948e+07
    temperature loop 1(1) : 20
    temperature loop 1(2) : 19.99
    temperature loop 1(3) : 20.3
    Heat exchange LH : 22.4
    temperature loop 2(1) : 23.58
    temperature loop 2(2) : 95.14
    temperature loop 2(3) : 119.99
    Heat exchange H2 : 22.4
    Heat exchange D2 : 24.1
    HPH H2 loop 1 : 32.8583
    HPH D2 loop 2 : 0.00123869
    -----