Run Number: 4382
End of Run Comment:
Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.1923,beam_raster=off,leftarm_p=1.007,leftarm_theta=12.5,leftarm_colli=out,bbarm_i=390,bbarm_theta=48,bbarm_colli=out,comment_text=Production Kinematic E
helicity test
PRESCALE FACTORS:ps1=43900 ps2=78000 ps3=4500 ps4=130 ps5=1 ps6=1 ps7=3700 ps8=4
EVENTS : [0]: 58720 [+]: 57861 [-]: 0
TIME : [0]: 3.823 mins [+]: 3.833 mins [-]: 0.017 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -5.33057 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 3.77% [+]: 5.45% [-]: 0.00%
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/26.7 Hz T2[0] : 0.0/67.4 Hz T3[0] : 0.0/27.4 Hz T4[0] : 0.1/7.8 Hz T5[0] :10.0/10.0 Hz T6[0] :10.0/10.0 Hz T7[0] : 0.0/17.1 Hz T8[0] :256.0/1024.0 Hz
T1[+] : 0.0/26.6 Hz T2[+] : 0.0/67.3 Hz T3[+] : 0.0/27.4 Hz T4[+] : 0.1/7.8 Hz T5[+] :10.0/10.0 Hz T6[+] :10.0/10.0 Hz T7[+] : 0.0/17.1 Hz T8[+] :256.0/1024.0 Hz
T1[-] : 0.0/0.0 Hz T2[-] : 0.0/0.0 Hz T3[-] : 0.0/0.0 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/6119 T2[0] : 0/15448 T3[0] : 1/6294 T4[0] : 13/1789 T5[0] : 2292/2292 T6[0] : 2292/2292 T7[0] : 1/3928 T8[0] : 58714/234858
T1[+] : 0/6122 T2[+] : 0/15469 T3[+] : 1/6304 T4[+] : 13/1789 T5[+] : 2303/2303 T6[+] : 2303/2303 T7[+] : 1/3931 T8[+] : 58877/235508
T1[-] : 0/0 T2[-] : 0/0 T3[-] : 0/0 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 0/0
AVERAGE CURRENT
BCM x1 : -0.0062uA BCM x3 : -0.0021uA BCM x10: -0.0015uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 1E+39 ppm BCM u3 : 1E+39 ppm BCM u10: 1E+39 ppm
BCM d1 : 1E+39 ppm BCM d3 : 1E+39 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:-1.23E-06 BCM u3 [0]:-3.935E-07 BCM u10[0]:2.479E-08
BCM u1 [+]:-1.234E-06 BCM u3 [+]:-3.992E-07 BCM u10[+]:2.153E-08
BCM u1 [-]:-1.528E-07 BCM u3 [-]:-4.801E-08 BCM u10[-]:-2.006E-08
BCM d1 [0]:-1.628E-06 BCM d3 [0]:-5.595E-07 BCM d10[0]:-7.214E-07
BCM d1 [+]:-1.636E-06 BCM d3 [+]:-5.592E-07 BCM d10[+]:-7.257E-07
BCM d1 [-]:-6.594E-08 BCM d3 [-]:-1.685E-08 BCM d10[-]:-1.367E-08
****************************
End-of-run EPICS data for Run Number 4382 at Tue Apr 29 10:46:36 EDT 2008
Wien angle : -40.2035
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 1.00698
Left Arm arm angle : 12.4507
Right Arm D1 momentum : 0.459612
Right Arm arm angle : 104.998
HALLA:p : 1192.38
HALLA:dpp : 0
Tiefenbach Hall A energy : 1192.38
Left Arm Top VDC Current : 4.88281
Left Arm Bottom VDC Current : 3.90625
-----
Left Arm Q1 momentum : 1.00704
Left Arm Q1 power supply : 757.679
Left Arm Q1 gauss meter : -0.06394
Left Arm Q2 gauss meter : 0.17147
Left Arm Q2 power supply current : 433.605
Left Arm Q2 momentum : 1.00698
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 334.435
Left Arm D1 momentum : 1.00698
Left Arm D1 NMR : 0.372841
Left Arm Q3 gauss meter : -0.2035
Left Arm Q3 power supply current : 400.82
Left Arm Q3 momentum : 1.00679
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.459677
Right Arm Q1 power supply : 345.647
Right Arm Q1 gauss meter : -0.008745
Right Arm Q2 power supply current : 197.778
Right Arm Q2 momentum : 0.459556
Right Arm Q2 gauss meter : 0.10405
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 158.185
Right Arm D1 momentum : 0.459612
Right Arm D1 NMR : 0.170556
Right Arm Q3 power supply current : 182.888
Right Arm Q3 momentum : 0.459623
Right Arm Q3 gauss meter : 0.08185
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 390
BigBite magnet current readback : 388.1
BigBite Gaussmeter readback : -0.3177
-----
Average current of the two cavities : 0.0240498
Current on Unser monitor : 11.894
Current on Upstream bcm : 0.0360957
Current on Downstream bcm : 0.0120039
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.0028765
Hall C Current : 0
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.38
Hall C energy (hallc_MeV) : 5712.39
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871289
HacL_HPE1313A:0_Ch58 : -0.249023
HacL_HPE1313A:0_Ch55 : 24.1699
HacL_HPE1313A:0_Ch54 : 0.17334
-----
Right Arm Collimator : -0.00874023
HacR_HPE1313A:0_Ch58 : -0.575195
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.833008
-----
Wien angle : -40.2035
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -934.12
Wien field : 26.736
Laser attenuation Hall A : 70
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.38509
SLI vert. size mm : 0
SLI y position : 1.60751
-----
Target : L1 6cm
fan frequency loop 1 : 31.5
fan frequency loop 2 : 14.5
Encoder position : 3.13948e+07
Target type : 3.13948e+07
temperature loop 1(1) : 20
temperature loop 1(2) : 19.99
temperature loop 1(3) : 20.28
Heat exchange LH : 22.4
temperature loop 2(1) : 23.55
temperature loop 2(2) : 95.14
temperature loop 2(3) : 119.99
Heat exchange H2 : 22.4
Heat exchange D2 : 24.1
HPH H2 loop 1 : 41.5355
HPH D2 loop 2 : 0.00123869
-----