Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 18:08:43 on April 29, 2008

    Entry number 235807

    keyword=End_of_Run_4387
    ****************************
     Run Number: 4387
     End of Run Comment:
    Run_type=Test,target_type=Tantalum,beam_e0=1.1923,beam_raster=off,leftarm_p=1.194,leftarm_theta=14.5,leftarm_colli=out,bbarm_i=390,bbarm_theta=54,bbarm_colli=out,comment_text=tests
     
    
    PRESCALE FACTORS:ps1=43900   ps2=78000   ps3=4500   ps4=130   ps5=1   ps6=1   ps7=3700   ps8=4   
    
    EVENTS   : [0]: 52249        [+]: 25750        [-]: 25717        
    TIME     : [0]: 3.209 mins  [+]: 1.615 mins  [-]: 1.614 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.30927 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   1.52%      [+]:   3.50%      [-]:   3.56%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.6/28560.9 Hz   T2[0] : 0.7/56036.7 Hz   T3[0] : 0.3/1366.6 Hz   T4[0] : 0.2/19.9 Hz   T5[0] :13.8/13.8 Hz   T6[0] :17.4/17.4 Hz   T7[0] : 0.3/1219.4 Hz   T8[0] :256.0/1024.0 Hz   
    T1[+] : 0.6/27990.5 Hz   T2[+] : 0.7/54933.3 Hz   T3[+] : 0.3/1335.1 Hz   T4[+] : 0.1/19.5 Hz   T5[+] :13.5/13.5 Hz   T6[+] :17.3/17.3 Hz   T7[+] : 0.3/1190.3 Hz   T8[+] :256.0/1024.0 Hz   
    T1[-] : 0.6/27943.5 Hz   T2[-] : 0.7/54806.5 Hz   T3[-] : 0.3/1341.4 Hz   T4[-] : 0.1/19.7 Hz   T5[-] :13.9/13.9 Hz   T6[-] :17.2/17.2 Hz   T7[-] : 0.3/1197.8 Hz   T8[-] :256.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    125/5499639  T2[0] :    138/10790352  T3[0] :     58/263152   T4[0] :     29/3829     T5[0] :   2649/2649     T6[0] :   3350/3350     T7[0] :     63/234798   T8[0] :  49295/197180   
    T1[+] :     61/2712481  T2[+] :     68/5323432  T3[+] :     28/129384   T4[+] :     14/1886     T5[+] :   1309/1309     T6[+] :   1672/1672     T7[+] :     31/115352   T8[+] :  24808/99233    
    T1[-] :     61/2706614  T2[-] :     68/5308580  T3[-] :     28/129930   T4[-] :     14/1912     T5[-] :   1344/1344     T6[-] :   1668/1668     T7[-] :     31/116016   T8[-] :  24796/99185    
    
    AVERAGE CURRENT
    BCM x1 : 2.9579 uA  BCM x3 : 2.9620 uA  BCM x10: 2.9868 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    687.8 ppm     BCM u3 :    803.8 ppm     BCM u10:    839.9 ppm     
    BCM d1 :    671.7 ppm     BCM d3 :    779.4 ppm     BCM d10:    829.8 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0005697      BCM u3 [0]:0.0005704      BCM u10[0]:0.0005747      
    BCM u1 [+]:0.0002809      BCM u3 [+]:0.0002813      BCM u10[+]:0.0002834      
    BCM u1 [-]:0.0002804      BCM u3 [-]:0.0002807      BCM u10[-]:0.0002828      
    
    BCM d1 [0]:0.0005694      BCM d3 [0]:0.0005703      BCM d10[0]:0.0005756      
    BCM d1 [+]:0.0002808      BCM d3 [+]:0.0002813      BCM d10[+]:0.0002838      
    BCM d1 [-]:0.0002803      BCM d3 [-]:0.0002807      BCM d10[-]:0.0002832      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4387 at Tue Apr 29 18:08:38 EDT 2008
    
    Wien angle : -40.2035
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 1.19398
    Left Arm arm angle : 14.5
    Right Arm D1 momentum : 0.45961
    Right Arm arm angle : 104.998
    HALLA:p : 1192.38
    HALLA:dpp : -7.00757e-07
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : -2.19727
    Left Arm Bottom VDC Current : 3.90625
    -----
    Left Arm Q1 momentum : 1.19388
    Left Arm Q1 power supply : 898.192
    Left Arm Q1 gauss meter : -0.07573
    Left Arm Q2 gauss meter : 0.2033
    Left Arm Q2 power supply current : 514.182
    Left Arm Q2 momentum : 1.19411
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 397.984
    Left Arm D1 momentum : 1.19398
    Left Arm D1 NMR : 0.441995
    Left Arm Q3 gauss meter : -0.2411
    Left Arm Q3 power supply current : 475.391
    Left Arm Q3 momentum : 1.19409
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.459677
    Right Arm Q1 power supply : 345.647
    Right Arm Q1 gauss meter : -0.0087
    Right Arm Q2 power supply current : 197.776
    Right Arm Q2 momentum : 0.459552
    Right Arm Q2 gauss meter : 0.10405
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 158.186
    Right Arm D1 momentum : 0.459611
    Right Arm D1 NMR : 0.170556
    Right Arm Q3 power supply current : 182.885
    Right Arm Q3 momentum : 0.459615
    Right Arm Q3 gauss meter : 0.08185
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 390
    BigBite magnet current readback : 388.1
    BigBite Gaussmeter readback : -0.3176
    -----
    Average current of the two cavities : 2.87701
    Current on Unser monitor : 13.9051
    Current on Upstream bcm : 2.83609
    Current on Downstream bcm : 2.91794
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 2.92055
    Hall C Current : 0
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : -1.14847e-06
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5710.71
    Delta(E)/E width (MV_AI_DXWID) : 1.05671
    IPM1C12.XPOS : 0.0105613
    IPM1H04A.XPOS : -0.831558
    IPM1H04A.YPOS : 0.703512
    IPM1H04B.XPOS : -1.28469
    IPM1H04B.YPOS : 1.61472
    -----
    Left Arm Collimator : 0.871289
    HacL_HPE1313A:0_Ch58 : -0.211426
    HacL_HPE1313A:0_Ch55 : 24.2676
    HacL_HPE1313A:0_Ch54 : 0.0947266
    -----
    Right Arm Collimator : -0.00834961
    HacR_HPE1313A:0_Ch58 : -0.574219
    HacR_HPE1313A:0_Ch55 : 22.7539
    HacR_HPE1313A:0_Ch54 : -0.833984
    -----
    Wien angle : -40.2035
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -934.12
    Wien field : 26.736
    Laser attenuation Hall A : 83
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.37019
    SLI vert. size mm : 0
    SLI y position : 2.00563
    -----
    Target : Tantalum
    fan frequency loop 1 : 31
    fan frequency loop 2 : 14
    Encoder position : 7.47761e+06
    Target type : 7.47761e+06
    temperature loop 1(1) : 20
    temperature loop 1(2) : 20
    temperature loop 1(3) : 20.3
    Heat exchange LH : 22.4
    temperature loop 2(1) : 23.56
    temperature loop 2(2) : 25.25
    temperature loop 2(3) : 119.99
    Heat exchange H2 : 22.4
    Heat exchange D2 : 24.1
    HPH H2 loop 1 : 39.1884
    HPH D2 loop 2 : 0.00710569
    -----