Run Number: 4391
End of Run Comment:
Run_type=Calibration,target_type=Carbon,beam_e0=1.1923,beam_raster=off,leftarm_p=1.194,leftarm_theta=14.5,leftarm_colli=out,bbarm_i=390,bbarm_theta=54,bbarm_colli=out,comment_text=tests
PRESCALE FACTORS:ps1=7800 ps2=13000 ps3=10 ps4=1 ps5=1 ps6=1 ps7=100 ps8=100
EVENTS : [0]: 502965 [+]: 248216 [-]: 247357
TIME : [0]: 16.474 mins [+]: 8.147 mins [-]: 8.148 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.93594 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 39.40% [+]: 39.61% [-]: 39.73%
TRIGGER RATES: PRES/REAL
T1[0] : 6.0/46428.5 Hz T2[0] : 5.7/74707.7 Hz T3[0] :648.6/6485.7 Hz T4[0] :61.4/61.4 Hz T5[0] :41.1/41.1 Hz T6[0] :65.3/65.3 Hz T7[0] :59.0/5896.3 Hz T8[0] :10.2/1024.0 Hz
T1[+] : 6.0/46481.7 Hz T2[+] : 5.8/74800.5 Hz T3[+] :649.8/6497.8 Hz T4[+] :61.2/61.2 Hz T5[+] :41.2/41.2 Hz T6[+] :65.4/65.4 Hz T7[+] :59.1/5908.5 Hz T8[+] :10.2/1024.0 Hz
T1[-] : 6.0/46429.8 Hz T2[-] : 5.7/74706.2 Hz T3[-] :648.2/6481.8 Hz T4[-] :61.7/61.7 Hz T5[-] :41.0/41.0 Hz T6[-] :65.3/65.3 Hz T7[-] :58.9/5891.5 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 5883/45892510 T2[0] : 5680/73845179 T3[0] : 641081/6410811 T4[0] : 60696/60696 T5[0] : 40599/40599 T6[0] : 64576/64576 T7[0] : 58282/5828216 T8[0] : 10121/1012178
T1[+] : 2913/22722222 T2[+] : 2812/36565593 T3[+] : 317639/3176391 T4[+] : 29934/29934 T5[+] : 20119/20119 T6[+] : 31962/31962 T7[+] : 28883/2888345 T8[+] : 5005/500574
T1[-] : 2910/22699797 T2[-] : 2809/36524273 T3[-] : 316900/3169007 T4[-] : 30155/30155 T5[-] : 20039/20039 T6[-] : 31931/31931 T7[-] : 28803/2880376 T8[-] : 5006/500639
AVERAGE CURRENT
BCM x1 : 1.6995 uA BCM x3 : 1.7035 uA BCM x10: 1.7178 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 434.2 ppm BCM u3 : 575.7 ppm BCM u10: 632.8 ppm
BCM d1 : 404.1 ppm BCM d3 : 564.3 ppm BCM d10: 628 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.00168 BCM u3 [0]:0.001684 BCM u10[0]:0.001697
BCM u1 [+]:0.0008318 BCM u3 [+]:0.0008336 BCM u10[+]:0.0008402
BCM u1 [-]:0.0008312 BCM u3 [-]:0.0008328 BCM u10[-]:0.0008392
BCM d1 [0]:0.00168 BCM d3 [0]:0.001684 BCM d10[0]:0.001699
BCM d1 [+]:0.0008315 BCM d3 [+]:0.0008339 BCM d10[+]:0.0008414
BCM d1 [-]:0.0008309 BCM d3 [-]:0.0008331 BCM d10[-]:0.0008405
****************************
End-of-run EPICS data for Run Number 4391 at Tue Apr 29 18:51:31 EDT 2008
Wien angle : -40.2035
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 1.19398
Left Arm arm angle : 14.5
Right Arm D1 momentum : 0.45961
Right Arm arm angle : 104.998
HALLA:p : 1192.38
HALLA:dpp : 0
Tiefenbach Hall A energy : 1192.38
Left Arm Top VDC Current : 5.0293
Left Arm Bottom VDC Current : -1.46484
-----
Left Arm Q1 momentum : 1.19388
Left Arm Q1 power supply : 898.192
Left Arm Q1 gauss meter : -0.07573
Left Arm Q2 gauss meter : 0.2033
Left Arm Q2 power supply current : 514.182
Left Arm Q2 momentum : 1.19411
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 397.982
Left Arm D1 momentum : 1.19398
Left Arm D1 NMR : 0.441995
Left Arm Q3 gauss meter : -0.2411
Left Arm Q3 power supply current : 475.39
Left Arm Q3 momentum : 1.19409
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.459677
Right Arm Q1 power supply : 345.647
Right Arm Q1 gauss meter : -0.008715
Right Arm Q2 power supply current : 197.777
Right Arm Q2 momentum : 0.459553
Right Arm Q2 gauss meter : 0.10406
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 158.184
Right Arm D1 momentum : 0.45961
Right Arm D1 NMR : 0.170556
Right Arm Q3 power supply current : 182.884
Right Arm Q3 momentum : 0.459613
Right Arm Q3 gauss meter : 0.08185
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 390
BigBite magnet current readback : 388.1
BigBite Gaussmeter readback : -0.3177
-----
Average current of the two cavities : 1.01974
Current on Unser monitor : 13.4492
Current on Upstream bcm : 0.0376208
Current on Downstream bcm : 2.00186
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 74.7217
Hall C Current : 77.46
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.38
Hall C energy (hallc_MeV) : 5712.28
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871289
HacL_HPE1313A:0_Ch58 : -0.210449
HacL_HPE1313A:0_Ch55 : 24.2188
HacL_HPE1313A:0_Ch54 : 0.0942383
-----
Right Arm Collimator : -0.00830078
HacR_HPE1313A:0_Ch58 : -0.574219
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.833008
-----
Wien angle : -40.2035
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -934.12
Wien field : 26.736
Laser attenuation Hall A : 70
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.42981
SLI vert. size mm : 0
SLI y position : 2.34366
-----
Target : Carbon
fan frequency loop 1 : 31
fan frequency loop 2 : 12.5
Encoder position : 9.10319e+06
Target type : 9.10319e+06
temperature loop 1(1) : 20
temperature loop 1(2) : 19.99
temperature loop 1(3) : 20.28
Heat exchange LH : 22.4
temperature loop 2(1) : 23.54
temperature loop 2(2) : 25.38
temperature loop 2(3) : 119.99
Heat exchange H2 : 22.4
Heat exchange D2 : 24.1
HPH H2 loop 1 : 37.8778
HPH D2 loop 2 : 0.00356948
-----