keyword=End_of_Run_4395
****************************
Run Number: 4395
End of Run Comment:
Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=1.1923,beam_raster=off,leftarm_p=1.194,leftarm_theta=14.5,leftarm_colli=out,bbarm_i=390,bbarm_theta=54,bbarm_colli=out,comment_text=tests
PRESCALE FACTORS:ps1=32000 ps2=58000 ps3=432 ps4=5 ps5=45 ps6=80 ps7=15600 ps8=100
EVENTS : [0]: 1002472 [+]: 493802 [-]: 493749
TIME : [0]: 16.511 mins [+]: 8.168 mins [-]: 8.167 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -5.12891 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 11.13% [+]: 11.52% [-]: 11.49%
TRIGGER RATES: PRES/REAL
T1[0] : 9.6/306378.0 Hz T2[0] : 9.5/552203.9 Hz T3[0] :469.6/202876.9 Hz T4[0] :445.2/2226.0 Hz T5[0] :94.6/4256.8 Hz T6[0] :92.1/7369.3 Hz T7[0] : 9.4/146400.3 Hz T8[0] :10.2/1024.0 Hz
T1[+] : 9.6/306631.3 Hz T2[+] : 9.5/552639.3 Hz T3[+] :469.9/203019.0 Hz T4[+] :444.8/2224.2 Hz T5[+] :94.7/4262.5 Hz T6[+] :92.3/7380.7 Hz T7[+] : 9.4/146505.1 Hz T8[+] :10.2/1024.0 Hz
T1[-] : 9.6/306169.5 Hz T2[-] : 9.5/551872.9 Hz T3[-] :469.4/202761.2 Hz T4[-] :445.5/2227.5 Hz T5[-] :94.5/4251.2 Hz T6[-] :92.0/7358.6 Hz T7[-] : 9.4/146317.6 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 9484/303514947 T2[0] : 9431/547043756 T3[0] : 465233/200981070 T4[0] : 441045/2205228 T5[0] : 93712/4217040 T6[0] : 91255/7300458 T7[0] : 9296/145032215 T8[0] : 10144/1014431
T1[+] : 4695/150266710 T2[+] : 4669/270824541 T3[+] : 230302/99490829 T4[+] : 217994/1089974 T5[+] : 46419/2088878 T6[+] : 45211/3616957 T7[+] : 4602/71795803 T8[+] : 5018/501818
T1[-] : 4688/150037114 T2[-] : 4662/270443042 T3[-] : 230005/99362278 T4[-] : 218313/1091565 T5[-] : 46295/2083301 T6[-] : 45075/3606063 T7[-] : 4596/71702334 T8[-] : 5018/501807
AVERAGE CURRENT
BCM x1 : 3.3064 uA BCM x3 : 3.3101 uA BCM x10: 3.3378 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 561.2 ppm BCM u3 : 622.3 ppm BCM u10: 650.8 ppm
BCM d1 : 537.1 ppm BCM d3 : 612.9 ppm BCM d10: 648.8 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.003276 BCM u3 [0]:0.003279 BCM u10[0]:0.003304
BCM u1 [+]:0.001622 BCM u3 [+]:0.001623 BCM u10[+]:0.001636
BCM u1 [-]:0.00162 BCM u3 [-]:0.001621 BCM u10[-]:0.001634
BCM d1 [0]:0.003275 BCM d3 [0]:0.003279 BCM d10[0]:0.003309
BCM d1 [+]:0.001621 BCM d3 [+]:0.001623 BCM d10[+]:0.001638
BCM d1 [-]:0.001619 BCM d3 [-]:0.001621 BCM d10[-]:0.001636
****************************
End-of-run EPICS data for Run Number 4395 at Tue Apr 29 19:38:43 EDT 2008
Wien angle : -40.2035
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 1.19398
Left Arm arm angle : 14.5
Right Arm D1 momentum : 0.459612
Right Arm arm angle : 104.998
HALLA:p : 1192.38
HALLA:dpp : -3.16939e-06
Tiefenbach Hall A energy : 1192.38
Left Arm Top VDC Current : -11.6211
Left Arm Bottom VDC Current : -7.71484
-----
Left Arm Q1 momentum : 1.19388
Left Arm Q1 power supply : 898.192
Left Arm Q1 gauss meter : -0.07571
Left Arm Q2 gauss meter : 0.2033
Left Arm Q2 power supply current : 514.178
Left Arm Q2 momentum : 1.1941
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 397.984
Left Arm D1 momentum : 1.19398
Left Arm D1 NMR : 0.441995
Left Arm Q3 gauss meter : -0.2411
Left Arm Q3 power supply current : 475.388
Left Arm Q3 momentum : 1.19409
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.459606
Right Arm Q1 power supply : 345.647
Right Arm Q1 gauss meter : -0.008718
Right Arm Q2 power supply current : 197.776
Right Arm Q2 momentum : 0.459553
Right Arm Q2 gauss meter : 0.10406
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 158.186
Right Arm D1 momentum : 0.459612
Right Arm D1 NMR : 0.170556
Right Arm Q3 power supply current : 182.885
Right Arm Q3 momentum : 0.459616
Right Arm Q3 gauss meter : 0.08185
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 390
BigBite magnet current readback : 388.1
BigBite Gaussmeter readback : -0.3176
-----
Average current of the two cavities : 3.4614
Current on Unser monitor : 14.1282
Current on Upstream bcm : 3.40605
Current on Downstream bcm : 3.51675
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 78.1352
Hall C Current : 75.9
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
Hall A momentum orbit correction (dpp) : -4.74843e-06
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.38
Hall C energy (hallc_MeV) : 5712.24
Delta(E)/E width (MV_AI_DXWID) : 1.25221
IPM1C12.XPOS : -0.00788677
IPM1H04A.XPOS : -0.802637
IPM1H04A.YPOS : 0.78064
IPM1H04B.XPOS : -1.30046
IPM1H04B.YPOS : 1.73297
-----
Left Arm Collimator : 0.87124
HacL_HPE1313A:0_Ch58 : -0.209961
HacL_HPE1313A:0_Ch55 : 24.2188
HacL_HPE1313A:0_Ch54 : 0.0942383
-----
Right Arm Collimator : -0.00869141
HacR_HPE1313A:0_Ch58 : -0.574219
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.833984
-----
Wien angle : -40.2035
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -934.12
Wien field : 26.736
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.42981
SLI vert. size mm : 0
SLI y position : 2.35117
-----
Target : L1 6cm
fan frequency loop 1 : 31
fan frequency loop 2 : 15
Encoder position : 3.13948e+07
Target type : 3.13948e+07
temperature loop 1(1) : 20
temperature loop 1(2) : 19.99
temperature loop 1(3) : 20.3
Heat exchange LH : 22.5
temperature loop 2(1) : 23.52
temperature loop 2(2) : 25.07
temperature loop 2(3) : 119.99
Heat exchange H2 : 22.5
Heat exchange D2 : 24.1
HPH H2 loop 1 : 32.8583
HPH D2 loop 2 : 0.00356948
-----