Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 19:53:20 on April 29, 2008

    Entry number 235831

    keyword=End_of_Run_20804
    ****************************
     Run Number: 20804
     End of Run Comment:
    Run_type=Calibration,target_type=Carbon,beam_e0=1.1932,beam_raster=off,beam_halfwaveplate=in,rightarm_p=0.4596,rightarm_theta=105,rightarm_colli=out,comment_text=production Kinematic E
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 112065       [+]: 56191        [-]: 55874        
    TIME     : [0]: 87.727 mins  [+]: 43.902 mins  [-]: 43.804 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       -82.94061 seconds
    
    
    DEAD TIME: [0]:   5.75%      [+]:   5.76%      [-]:   5.77%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :14.4/14.4 Hz   T2[0] : 8.2/8.2  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :14.4/14.4 Hz   T2[+] : 8.2/8.2  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :14.4/14.4 Hz   T2[-] : 8.1/8.1  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  75819/75819    T2[0] :  43015/43015    T8[0] :     82/5389921  
    T1[+] :  37944/37944    T2[+] :  21644/21644    T8[+] :     41/2697313  
    T1[-] :  37891/37891    T2[-] :  21371/21371    T8[-] :     41/2691321  
    
    AVERAGE CURRENT
    BCM x1 : 2.5572 uA  BCM x3 : 2.5608 uA  BCM x10: 1.2769 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -715.9 ppm     BCM u3 :     -577 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :     -702 ppm     BCM d3 :   -571.3 ppm     BCM d10:   -522.9 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01347        BCM u3 [0]:0.01348        BCM u10[0]:-0.0001057     
    BCM u1 [+]:0.006739       BCM u3 [+]:0.006746       BCM u10[+]:-5.288E-05     
    BCM u1 [-]:0.006733       BCM u3 [-]:0.006738       BCM u10[-]:-5.276E-05     
    
    BCM d1 [0]:0.01345        BCM d3 [0]:0.01348        BCM d10[0]:0.01355        
    BCM d1 [+]:0.006728       BCM d3 [+]:0.006742       BCM d10[+]:0.006779       
    BCM d1 [-]:0.006723       BCM d3 [-]:0.006735       BCM d10[-]:0.006771       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 20804 at Tue Apr 29 19:52:45 EDT 2008
    
    Wien angle : -40.2035
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.997005
    Left Arm arm angle : 14.5
    Right Arm D1 momentum : 0.459611
    Right Arm arm angle : 104.998
    HALLA:p : 1192.38
    HALLA:dpp : -6.06825e-07
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : 1.02539
    Left Arm Bottom VDC Current : -0.244141
    ----
    Left Arm Q1 momentum : 0.996957
    Left Arm Q1 power supply : 750.042
    Left Arm Q1 gauss meter : -0.0633
    Left Arm Q2 gauss meter : 0.16981
    Left Arm Q2 power supply current : 429.392
    Left Arm Q2 momentum : 0.997195
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 331.025
    Left Arm D1 momentum : 0.997005
    Left Arm D1 NMR : 0.36915
    Left Arm Q3 gauss meter : -0.2015
    Left Arm Q3 power supply current : 396.865
    Left Arm Q3 momentum : 0.99685
    Left Arm Q3 power supply polarity : disabled
    ----
    Right Arm Q1 momentum : 0.459677
    Right Arm Q1 power supply : 345.647
    Right Arm Q1 gauss meter : -0.00873
    Right Arm Q2 power supply current : 197.775
    Right Arm Q2 momentum : 0.45955
    Right Arm Q2 gauss meter : 0.10406
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 158.186
    Right Arm D1 momentum : 0.459611
    Right Arm D1 NMR : 0.170556
    Right Arm Q3 power supply current : 182.884
    Right Arm Q3 momentum : 0.459614
    Right Arm Q3 gauss meter : 0.08185
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 390
    BigBite magnet current readback : 388.1
    BigBite magnet magnet probe : -0.3176
    -----
    Average current of the two cavities : 3.49054
    Current on Unser monitor : 15.3016
    Current on Upstream bcm : 3.44266
    Current on Downstream bcm : 3.53841
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 78.6134
    Hall C Current : 76.77
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : -6.06825e-07
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5712.25
    Delta(E)/E width (MV_AI_DXWID) : 0.524888
    IPM1C12.XPOS : -0.0140085
    IPM1H04A.XPOS : -0.809057
    IPM1H04A.YPOS : 0.734617
    IPM1H04B.XPOS : -1.30515
    IPM1H04B.YPOS : 1.67433
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.210938
    HacL_HPE1313A:0_Ch55 : 24.2676
    HacL_HPE1313A:0_Ch54 : 0.0947266
    -----
    Right Arm Collimator : -0.00864258
    HacR_HPE1313A:0_Ch58 : -0.57373
    HacR_HPE1313A:0_Ch55 : 22.7539
    HacR_HPE1313A:0_Ch54 : -0.833496
    -----
    Wien angle : -40.2035
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -934.12
    Wien field : 26.736
    Laser attenuation Hall A : 97
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : hlat:MV_AI_DXPOS --- Invalid channel name
    Target OTR y-position : hlat:MV_AI_DYPOS --- Invalid channel name
    Target OTR x-width : hlat:MV_AI_DXWID --- Invalid channel name
    Target OTR y-width : hlat:MV_AI_DYWID --- Invalid channel name
    Target OTR data valid flag : hlat:DataValid --- Invalid channel name
    Target OTR In/Out : hlat:DataReason --- Invalid channel name
    Arc OTR x-position : -10.5973
    Arc OTR y-position : 5
    Arc OTR x-width : 0
    Arc OTR y-width : -0
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.42981
    SLI vert. size mm : 0
    SLI y position : 2.3662
    -----
    Target : L1 6cm
    Vacuum Pressure : 2.43635e-07
    fan frequency loop 1 : 31
    fan frequency loop 2 : 14
    fan frequency loop 3 : 0
    Encoder position : 3.13948e+07
    Target type : 3.13948e+07
    temperature loop 1(1) : 19.99
    temperature loop 1(2) : 19.99
    temperature loop 1(3) : 20.29
    Heat exchange He2 : 22.4
    temperature loop 2(1) : 23.53
    temperature loop 2(2) : 25.31
    temperature loop 2(3) : 119.99
    Heat exchange D2 : 24.1
    HPH He loop 1 : 33.7723
    HPH He loop 2 : 0.00710569