Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 02:24:06 on May 16, 2008

    Entry number 238163

    keyword=Start_Run_1142,Run_type=Calibration,target_type=Tantalum,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=calibration
    Run Timestamp:       Fri May 16 02:22:47 EDT 2008
    Beginning-of-run EPICS data for Run Number 1142 at Fri May 16 02:23:38 EDT 2008
    
    
    
    Run_type=Calibration
    target_type=Tantalum
    beam_e0=1.192
    beam_raster=on
    leftarm_p=0.6286
    leftarm_theta=57.5
    leftarm_colli=out
    bbarm_i=700
    bbarm_theta=30.25
    bbarm_zoff=
    comment_text=calibration
    
    
    ; BBite+HRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = BigBite Calorimeter
    ; T2 = undefined
    ; T3 = L-HRS Singles (S1.and.S2)
    ; T4 = L-HRS Efficiency (S1.or.S2)
    ; T5 = T1.AND.T3 (BigBite LHRS Coincidence)
    ; T6 = undefined
    ; T7 = BigBite Cosmics
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return
    
    ps1=1,ps2=16777215,ps3=1,ps4=1000,ps5=1,ps6=65535,ps7=1,ps8=100
    
    
    
    Left Arm Q1 momentum : 0.628529
    Left Arm Q1 power supply : 472.862
    Left Arm Q1 gauss meter : 0.04056
    Left Arm Q2 power supply current : 270.698
    Left Arm Q2 momentum : 0.628654
    Left Arm Q2 gauss meter : -0.1072
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 208.642
    Left Arm D1 momentum : 0.628596
    Left Arm D1 NMR : 0.264705
    Left Arm Q3 power supply current : 250.259
    Left Arm Q3 momentum : 0.628604
    Left Arm Q3 gauss meter : -0.12688
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : 0.2251
    -----
    Right Arm Q1 momentum : 0.00343584
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.83e-05
    Right Arm Q2 power supply current : -0.000244028
    Right Arm Q2 momentum : -1.63234e-07
    Right Arm Q2 gauss meter : -0.0002881
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0276724
    Right Arm D1 momentum : 0.00446352
    Right Arm D1 NMR : 0.301258
    Right Arm Q3 power supply current : 0.000112089
    Right Arm Q3 momentum : 0.000278742
    Right Arm Q3 gauss meter : -0.0002504
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : -0.0016303
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.5467
    -----
    Left Arm Top VDC Current : -1.80664
    Left Arm Bottom VDC Current : 0.634766
    Left Arm Top VDC voltage : 3.98584
    Left Arm Bottom VDC voltage : 3.99072
    -----
    Right Arm Top VDC Current : -1.2207
    Right Arm Bottom VDC Current : -1.12305
    Right Arm Top VDC voltage : -0.0112305
    Right Arm Bottom VDC voltage : 0.00146484
    -----
    Average current of the two cavities : 4.27145
    Current on Unser monitor : 17.436
    Current on Upstream bcm : 4.1936
    Current on Downstream bcm : 4.34929
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 83.3291
    Hall C Current : ibcm1 --- Invalid channel name
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.28
    Hall A momentum orbit correction (dpp) : -0.000241995
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.28
    Hall C energy (hallc_MeV) : 5710.5
    Delta(E)/E width (MV_AI_DXWID) : 1.43113
    MBSY1c magnet current (amp) : 49.4616
    MBSY1c Bdl : 297839
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 1.5
    Raster Y width : 1.5
    -----
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.355957
    Left Arm Angle Floor Angle : 57.5
    Left Arm Angle Vernier : 31.1
    Left Arm Scattering Angle : 57.5003
    -----
    Right Arm Arm Collimator : -0.00844727
    HacR_HPE1313A:0_Ch58 : -0.575195
    HacR_HPE1313A:0_Ch55 : 22.0215
    HacR_HPE1313A:0_Ch54 : -0.841309
    Right Arm Angle Floor Angle : 105
    Right Arm Angle Vernier : -34.4
    Right Arm Scattering Angle : 104.999
    -----
    IPM1C12.XPOS : 1.00912
    IPM1C12.YPOS : 0.487037
    IPM1H04A.XPOS : 1.14103
    IPM1H04A.YPOS : 0.868506
    IPM1H04B.XPOS : 0.902279
    IPM1H04B.YPOS : 1.30801
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : -33.7301
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 22.411
    Laser attenuation Hall A : 86
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 2 : 0
    fan frequency loop 3 : 36
    Encoder position : 7.47761e+06
    Target type : 7.47761e+06
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    Heat exchange loop 1 H2 : 106.4
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange loop 3 H2 : 20
    pressure loop He : 41.1817
    pressure loop H2 before : 29.9641
    pressure loop H2 return : 30.1701
    HPH He loop 1 : 0.0322691
    HPH H2 loop 3 : 60.3064
    ----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.32547
    SLI vert. size mm : 0
    SLI y position : 2.35117
    -----
    FPP High Voltages and Currents at Fri May 16 02:23:49 EDT 2008
    MF7b1469_7gn0gen.F            1750.8
    MF7b1469_7gn0gen.E            0.2
    MF7b1469_7gn0ch0property.F    1750.8
    MF7b1469_7gn0ch0property.E    -0
    MF7b1469_7gn0ch1property.F    1750.8
    MF7b1469_7gn0ch1property.E    0.02
    MF7b1469_7gn0ch2property.F    1750.8
    MF7b1469_7gn0ch2property.E    0.01
    MF7b1469_7gn0ch3property.F    1750.8
    MF7b1469_7gn0ch3property.E    0.01
    MF7b1469_7gn0ch4property.F    1750.8
    MF7b1469_7gn0ch4property.E    0.01
    MF7b1469_7gn1gen.F            1750.2
    MF7b1469_7gn1gen.E            0.4
    MF7b1469_7gn1ch0property.F    1750.2
    MF7b1469_7gn1ch0property.E    0.01
    MF7b1469_7gn1ch1property.F    1750.2
    MF7b1469_7gn1ch1property.E    0.02
    MF7b1469_7gn1ch2property.F    1750.2
    MF7b1469_7gn1ch2property.E    0
    MF7b1469_7gn1ch3property.F    1750.2
    MF7b1469_7gn1ch3property.E    0.01
    MF7b1469_7gn1ch4property.F    1750.2
    MF7b1469_7gn1ch4property.E    0.03
    MF7b1469_8gn0gen.F            1749.3
    MF7b1469_8gn0gen.E            1.1
    MF7b1469_8gn0ch0property.F    1749.3
    MF7b1469_8gn0ch0property.E    -0.02
    MF7b1469_8gn0ch1property.F    1749.3
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    1749.3
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    1749.3
    MF7b1469_8gn0ch3property.E    0.01
    MF7b1469_8gn0ch4property.F    1749.3
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            1748.5
    MF7b1469_8gn1gen.E            1.8
    MF7b1469_8gn1ch0property.F    1748.5
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    1748.5
    MF7b1469_8gn1ch1property.E    0.01
    MF7b1469_8gn1ch2property.F    1748.5
    MF7b1469_8gn1ch2property.E    0
    MF7b1469_8gn1ch3property.F    1748.5
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    1748.5
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            23.4
    MF7b1469_8gn2gen.E            0.7
    MF7b1469_8gn2ch0property.F    0
    MF7b1469_8gn2ch0property.E    0
    
    FPP Chamber Threshold voltages at Fri May 16 02:23:51 EDT 2008
    HrsH_FPP_TH1                  3.89844
    HrsH_FPP_TH2                  4.02686
    HrsH_FPP_TH3                  6.96045
    HrsH_FPP_TH4                  7.06738
    
    FPP Wire Chambers Low Voltage at Fri May 16 02:23:51 EDT 2008
    HrsH_FPP_LV11P                4.92041
    HrsH_FPP_LV11M                -5.3418
    HrsH_FPP_LV12MA               -5.26562
    HrsH_FPP_LV12MB               -5.58594
    HrsH_FPP_LV21P                5.08301
    HrsH_FPP_LV21M                -4.54834
    HrsH_FPP_LV22MA               -4.71289
    HrsH_FPP_LV22MB               -4.72363
    HrsH_FPP_LV31P                4.79932
    HrsH_FPP_LV31M                -5.11084
    HrsH_FPP_LV32MA               -2.78467
    HrsH_FPP_LV32MB               -1.49951
    HrsH_FPP_LV42P                4.76025
    HrsH_FPP_LV42MA               -4.7207
    HrsH_FPP_LV42MB               -4.57764
    HrsH_FPP_LV41P                4.72217
    HrsH_FPP_LV41MA               -4.77295
    HrsH_FPP_LV41MB               -4.61279
    
    FPP Level Shifters at Fri May 16 02:23:52 EDT 2008
    HacH_DTC_HPE1313A:0_Ch48      5.07129
    HacH_DTC_HPE1313A:0_Ch50      -5.11328
    
    FPP Gas Flow at Fri May 16 02:23:52 EDT 2008
    HrsH_GAS_rFPPc1               4.59283
    HrsH_GAS_rFPPc2               2.66378
    HrsH_GAS_rFPPc3               4.85771
    HrsH_GAS_rFPPc4               5.89102
    
    FPP Carbon Door Status at Fri May 16 02:23:52 EDT 2008
    HacH_DTC_VMIC1182:0_Ch13      enabled
    HacH_DTC_VMIC1182:0_Ch17      enabled
    HacH_DTC_VMIC1182:0_Ch9       enabled
    HacH_DTC_VMIC1182:0_Ch5       enabled
    
    Left S2 HV
    S2 Slot0 ch0 : -2310.3
    S2 Slot0 ch1 : -2212.3
    S2 Slot0 ch2 : -2166.4
    S2 Slot0 ch3 : -2231.2
    S2 Slot0 ch4 : -1793.1
    S2 Slot0 ch5 : -2166.5
    S2 Slot0 ch6 : -1940.7
    S2 Slot0 ch7 : -1876.9
    S2 Slot0 ch8 : -2030.4
    S2 Slot0 ch9 : -1889.6
    S2 Slot0 ch10 : -2094.7
    S2 Slot0 ch11 : -1867.9
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1785.2
    S1 Slot1 ch1 : -1809.8
    S1 Slot1 ch2 : -1790.2
    S1 Slot1 ch3 : -1817.7
    S1 Slot1 ch4 : -1699.9
    S1 Slot1 ch5 : -1855.4
    S1 Slot1 ch6 : -1915.4
    S1 Slot1 ch7 : -1700.9
    S1 Slot1 ch8 : -1961.1
    S1 Slot1 ch9 : -1746.3
    S1 Slot1 ch10 : -1798.4
    S1 Slot1 ch11 : -1707.6
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1544.3
    GCER Slot2 ch1 : -1462.1
    GCER Slot2 ch2 : -1528
    GCER Slot2 ch3 : -1453
    GCER Slot2 ch4 : -1798.1
    GCER Slot2 ch5 : -1983.6
    GCER Slot2 ch6 : -1750.5
    GCER Slot2 ch7 : -1751.1
    GCER Slot2 ch8 : -2009.9
    GCER Slot2 ch9 : -1587.9
    GCER Slot2 ch10 : -15
    GCER Slot2 ch11 : -23.6
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -860.4
    PRL1 Slot3 ch1 : -784.5
    PRL1 Slot3 ch2 : -905.8
    PRL1 Slot3 ch3 : -980.5
    PRL1 Slot3 ch4 : -731.1
    PRL1 Slot3 ch5 : -811
    PRL1 Slot3 ch6 : -1081.3
    PRL1 Slot3 ch7 : -990.8
    PRL1 Slot3 ch8 : -810.5
    PRL1 Slot3 ch9 : -790.9
    PRL1 Slot3 ch10 : -829.5
    PRL1 Slot3 ch11 : -785.3
    PRL1 Slot4 ch0 : -870.1
    PRL1 Slot4 ch1 : -900.5
    PRL1 Slot4 ch2 : -750.8
    PRL1 Slot4 ch3 : -895.1
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -821.2
    PRL1 Slot4 ch6 : -836
    PRL1 Slot4 ch7 : -826.4
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -991.4
    PRL1 Slot4 ch10 : -1030.9
    PRL1 Slot4 ch11 : -861.4
    PRL1 Slot5 ch0 : -1041.1
    PRL1 Slot5 ch1 : -871
    PRL1 Slot5 ch2 : -916.2
    PRL1 Slot5 ch3 : -735.8
    PRL1 Slot5 ch4 : -890.7
    PRL1 Slot5 ch5 : -810.3
    PRL1 Slot5 ch6 : -821.1
    PRL1 Slot5 ch7 : -895.6
    PRL1 Slot5 ch8 : -741.3
    PRL1 Slot5 ch9 : -841.4
    PRL1 Slot5 ch10 : -16.5
    PRL1 Slot5 ch11 : -25.6
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -920.5
    PRL2 Slot9 ch1 : -881.3
    PRL2 Slot9 ch2 : -800.1
    PRL2 Slot9 ch3 : -869.9
    PRL2 Slot9 ch4 : -810.9
    PRL2 Slot9 ch5 : -941.5
    PRL2 Slot9 ch6 : -851.5
    PRL2 Slot9 ch7 : -890.6
    PRL2 Slot9 ch8 : -811.4
    PRL2 Slot9 ch9 : -780.6
    PRL2 Slot9 ch10 : -821
    PRL2 Slot9 ch11 : -851.4
    PRL2 Slot10 ch0 : -755.7
    PRL2 Slot10 ch1 : -812.4
    PRL2 Slot10 ch2 : -871
    PRL2 Slot10 ch3 : -900.8
    PRL2 Slot10 ch4 : -881.4
    PRL2 Slot10 ch5 : -871
    PRL2 Slot10 ch6 : -815.2
    PRL2 Slot10 ch7 : -824.8
    PRL2 Slot10 ch8 : -760.3
    PRL2 Slot10 ch9 : -715.7
    PRL2 Slot10 ch10 : -911
    PRL2 Slot10 ch11 : -781.3
    PRL2 Slot11 ch0 : -1000.7
    PRL2 Slot11 ch1 : -900.4
    PRL2 Slot11 ch2 : -850.6
    PRL2 Slot11 ch3 : -1079.9
    PRL2 Slot11 ch4 : -1050.2
    PRL2 Slot11 ch5 : -800
    PRL2 Slot11 ch6 : -860.4
    PRL2 Slot11 ch7 : -1031.3
    PRL2 Slot11 ch8 : -911.3
    PRL2 Slot11 ch9 : -880.3
    PRL2 Slot11 ch10 : -12.9
    PRL2 Slot11 ch11 : -24.7
    -----
    # Map  BB_DE  Measured Voltage
      1 :  -1316  -1496 
      2 :  -1420  -1333 
      3 :  -1301  -1467 
      4 :  -1632  -1618 
      5 :  -1362  -1251 
      6 :  -1444  -1444 
      7 :  -1284  -1302 
      8 :  -1345  -1601 
      9 :  -1174  -1651 
     10 :  -1567  -1301 
     11 :  -1481  -1528 
     12 :  -1281  -1564 
     13 :  -1583  -1549 
     14 :  -1167  -1550 
     15 :  -1380  -1573 
     16 :  -1403  -1301 
     17 :  -1161  -1600 
     18 :  -1431  -1400 
     19 :  -1514  -1521 
     20 :  -1369  -1546 
     21 :  -1559  -1414 
     22 :  -1494  -1619 
     23 :  -1737  -1414 
     24 :  -1558  -1284 
    # Map  BB_DE  Measured Current
      1 :   -136   -168 
      2 :   -152   -148 
      3 :   -138   -158 
      4 :   -173   -184 
      5 :   -148   -133 
      6 :   -154   -160 
      7 :   -141   -141 
      8 :   -142   -170 
      9 :   -127   -184 
     10 :   -165   -139 
     11 :   -156   -165 
     12 :   -140   -172 
     13 :   -173   -163 
     14 :   -126   -170 
     15 :   -150   -173 
     16 :   -149   -137 
     17 :   -126   -169 
     18 :   -159   -149 
     19 :   -170   -162 
     20 :   -154   -169 
     21 :   -168   -149 
     22 :   -168   -152 
     23 :   -193   -152 
     24 :   -168   -138 
    # Map  BB_E  Measured Voltage
      1 :  -1456  -1479 
      2 :  -1649  -1283 
      3 :  -1298  -1334 
      4 :  -1206  -1193 
      5 :  -1330  -1555 
      6 :  -1410  -1566 
      7 :  -1550  -1284 
      8 :  -1184  -1484 
      9 :  -1287  -1514 
     10 :  -1251  -1221 
     11 :  -1572  -1472 
     12 :  -1229  -1544 
     13 :  -1632  -1360 
     14 :  -1240  -1420 
     15 :  -1565  -1254 
     16 :  -1244  -1555 
     17 :  -1488  -1389 
     18 :  -1133  -1206 
     19 :  -1345  -1540 
     20 :  -1493  -1459 
     21 :  -1440  -1454 
     22 :  -1480  -1155 
     23 :  -1391  -1227 
     24 :  -1143     -3 
    # Map  BB_E  Measured Current
      1 :   -152   -158 
      2 :   -181   -133 
      3 :   -136   -150 
      4 :   -131   -129 
      5 :   -146   -168 
      6 :   -150   -171 
      7 :   -163   -139 
      8 :   -128   -161 
      9 :   -136   -160 
     10 :   -135   -124 
     11 :   -161   -157 
     12 :   -132   -163 
     13 :   -175   -140 
     14 :   -129   -145 
     15 :   -172   -131 
     16 :   -135   -147 
     17 :   -163   -152 
     18 :   -124   -124 
     19 :   -142   -165 
     20 :   -158   -158 
     21 :   -151   -150 
     22 :   -158   -119 
     23 :   -148   -128 
     24 :   -121      0 
    # Map  BB_SC_R  Measured Voltage
      1 :  -1176 
      2 :  -1154 
      3 :  -1174 
      4 :  -1159 
      5 :  -1190 
      6 :  -1201 
      7 :  -1267 
      8 :  -1126 
      9 :  -1196 
     10 :  -1274 
     11 :  -1306 
     12 :  -1176 
     13 :  -1293 
    # Map  BB_SC_R  Measured Current
      1 :   -444 
      2 :   -439 
      3 :   -444 
      4 :   -439 
      5 :   -450 
      6 :   -455 
      7 :   -481 
      8 :   -426 
      9 :   -452 
     10 :   -486 
     11 :   -495 
     12 :   -446 
     13 :   -489 
    # Map  BB_DC  Measured Voltage
      1 :     -0     -0     -0     -0 
      2 :     -0     -0     -0     -0 
      3 :     -0      0     -0      0 
    # Map  BB_DC  Measured Current
      1 :     -0     -0     -0     -0 
      2 :     -0     -0     -0     -0 
      3 :     -0     -0     -0     -0 
    # Map  BB_PS_R  Measured Voltage
      1 :   -883 
      2 :   -842 
      3 :   -845 
      4 :   -853 
      5 :   -858 
      6 :   -848 
      7 :   -829 
      8 :   -844 
      9 :   -895 
     10 :   -897 
     11 :   -842 
     12 :   -856 
     13 :   -860 
     14 :   -849 
     15 :   -817 
     16 :   -917 
     17 :   -787 
     18 :   -807 
     19 :   -824 
     20 :   -810 
     21 :   -815 
     22 :   -796 
     23 :   -815 
     24 :   -800 
     25 :   -765 
     26 :   -848 
     27 :   -850 
    # Map  BB_PS_R  Measured Current
      1 :   -228 
      2 :   -215 
      3 :   -216 
      4 :   -216 
      5 :   -220 
      6 :   -217 
      7 :   -213 
      8 :   -216 
      9 :   -229 
     10 :   -230 
     11 :   -215 
     12 :   -216 
     13 :   -220 
     14 :   -217 
     15 :   -210 
     16 :   -234 
     17 :   -201 
     18 :   -207 
     19 :   -212 
     20 :   -203 
     21 :   -210 
     22 :   -203 
     23 :   -209 
     24 :   -206 
     25 :   -197 
     26 :   -217 
     27 :   -219 
    # Map  BB_SC_L  Measured Voltage
      1 :  -1234 
      2 :  -1270 
      3 :  -1215 
      4 :  -1140 
      5 :  -1162 
      6 :  -1268 
      7 :  -1316 
      8 :  -1122 
      9 :  -1201 
     10 :  -1243 
     11 :  -1317 
     12 :  -1230 
     13 :  -1242 
    # Map  BB_SC_L  Measured Current
      1 :   -449 
      2 :   -424 
      3 :   -457 
      4 :   -411 
      5 :   -395 
      6 :   -458 
      7 :   -465 
      8 :   -405 
      9 :   -420 
     10 :   -477 
     11 :   -481 
     12 :   -473 
     13 :   -469 
    # Map  BB_PS_L  Measured Voltage
      1 :   -895 
      2 :   -885 
      3 :   -816 
      4 :   -888 
      5 :   -859 
      6 :   -867 
      7 :   -856 
      8 :   -804 
      9 :   -869 
     10 :   -894 
     11 :   -861 
     12 :   -865 
     13 :   -864 
     14 :   -858 
     15 :   -885 
     16 :   -861 
     17 :   -869 
     18 :   -914 
     19 :   -844 
     20 :   -864 
     21 :   -847 
     22 :   -845 
     23 :   -840 
     24 :   -862 
     25 :   -898 
     26 :   -854 
     27 :   -887 
    # Map  BB_PS_L  Measured Current
      1 :   -228 
      2 :   -225 
      3 :   -210 
      4 :   -227 
      5 :   -221 
      6 :   -220 
      7 :   -219 
      8 :   -206 
      9 :   -222 
     10 :   -229 
     11 :   -219 
     12 :   -225 
     13 :   -220 
     14 :   -222 
     15 :   -225 
     16 :   -220 
     17 :   -224 
     18 :   -235 
     19 :   -216 
     20 :   -221 
     21 :   -216 
     22 :   -219 
     23 :   -214 
     24 :   -221 
     25 :   -230 
     26 :   -218 
     27 :   -228 
    # Map  BB_SH  Measured Voltage
      1 :  -1316  -1420  -1301  -1632  -1585  -1721  -1322 
      2 :  -1362  -1444  -1284  -1469  -1329  -1252  -1517 
      3 :  -1345  -1174  -1567  -1481  -1456  -1552  -1496 
      4 :  -1281  -1583  -1167  -1586  -1501  -1801  -1528 
      5 :  -1380  -1403  -1161  -1431  -1401  -1376  -1484 
      6 :  -1514  -1369  -1559  -1702  -1666  -1415  -1277 
      7 :  -1494  -1737  -1558  -1496  -1617  -1417  -1577 
      8 :  -1333  -1467  -1618  -1051  -1586  -1683  -1426 
      9 :  -1251  -1444  -1302  -1601  -1459  -1301  -1651 
     10 :  -1651  -1301  -1528  -1171  -1232  -1276  -1494 
     11 :  -1564  -1549  -1550  -1573  -1351  -1400  -1300 
     12 :  -1301  -1600  -1400  -1601  -1500  -1598  -1666 
     13 :  -1521  -1546  -1414  -1619  -1216  -1526  -1557 
     14 :  -1414  -1284  -1456  -1322  -1503  -1530  -1534 
     15 :  -1649  -1298  -1206  -1330  -1519  -1412  -1461 
     16 :  -1410  -1550  -1184  -1591  -1386  -1538  -1212 
     17 :  -1287  -1251  -1572  -1229  -1418  -1481  -1523 
     18 :  -1632  -1240  -1565  -1189  -1627  -1402  -1342 
     19 :  -1244  -1488  -1133  -1345  -1343  -1603  -1316 
     20 :  -1493  -1440  -1480  -1279  -1671  -1366  -1463 
     21 :  -1391  -1143  -1479  -1283  -1571  -1402  -1234 
     22 :  -1334  -1193  -1555  -1377  -1566  -1518  -1421 
     23 :  -1566  -1284  -1484  -1514  -1601  -1180  -1322 
     24 :  -1221  -1472  -1544  -1464  -1281  -1471  -1346 
     25 :  -1360  -1420  -1254  -1555  -1327  -1304  -1510 
     26 :  -1389  -1206  -1540  -1281  -1263  -1522  -1417 
     27 :  -1459  -1454  -1155  -1227  -1261  -1420  -1425 
    # Map  BB_SH  Measured Current
      1 :   -136   -152   -138   -173   -169   -184   -140 
      2 :   -148   -154   -141   -157   -140   -133   -165 
      3 :   -142   -127   -165   -156   -152   -167   -158 
      4 :   -140   -173   -126   -165   -162   -184   -158 
      5 :   -150   -149   -126   -159   -139   -143   -154 
      6 :   -170   -154   -168   -177   -175   -146   -142 
      7 :   -168   -193   -168   -168   -170   -142   -168 
      8 :   -148   -158   -184   -116   -165   -184   -154 
      9 :   -133   -160   -141   -170   -159   -141   -174 
     10 :   -184   -139   -165   -130   -134   -135   -156 
     11 :   -172   -163   -170   -173   -147   -148   -142 
     12 :   -137   -169   -149   -168   -159   -170   -178 
     13 :   -162   -169   -149   -152   -129   -162   -163 
     14 :   -152   -138   -152   -137   -159   -167   -165 
     15 :   -181   -136   -131   -146   -160   -157   -154 
     16 :   -150   -163   -128   -172   -145   -160   -129 
     17 :   -136   -135   -161   -132   -145   -158   -162 
     18 :   -175   -129   -172   -125   -179   -151   -141 
     19 :   -135   -163   -124   -142   -145   -169   -139 
     20 :   -158   -151   -158   -139   -176   -144   -155 
     21 :   -148   -121   -158   -133   -166   -149   -132 
     22 :   -150   -129   -168   -146   -168   -162   -154 
     23 :   -171   -139   -161   -160   -170   -129   -135 
     24 :   -124   -157   -163   -163   -133   -157   -145 
     25 :   -138   -144   -133   -148   -142   -139   -161 
     26 :   -151   -123   -165   -138   -134   -166   -149 
     27 :   -159   -145   -120   -128   -130   -152   -158 
    # Map  BB_TESTMAP  Measured Voltage
      1 :  -1459  -1454  -1155  -1227  -1261  -1420  -1425 
      2 :  -1389  -1206  -1540  -1281  -1263  -1522  -1417 
      3 :  -1360  -1420  -1254  -1555  -1327  -1304  -1510 
      4 :  -1221  -1472  -1544  -1464  -1281  -1471  -1346 
      5 :  -1566  -1284  -1484  -1514  -1601  -1180  -1322 
      6 :  -1334  -1193  -1555  -1377  -1566  -1518  -1421 
      7 :  -1391  -1143  -1479  -1283  -1571  -1402  -1234 
      8 :  -1493  -1440  -1480  -1279  -1671  -1366  -1463 
      9 :  -1244  -1488  -1133  -1345  -1343  -1603  -1316 
     10 :  -1632  -1240  -1565  -1189  -1627  -1402  -1342 
     11 :  -1287  -1251  -1572  -1229  -1418  -1481  -1523 
     12 :  -1410  -1550  -1184  -1591  -1386  -1538  -1212 
     13 :  -1649  -1298  -1206  -1330  -1519  -1412  -1461 
     14 :  -1414  -1284  -1456  -1322  -1503  -1530  -1534 
     15 :  -1521  -1546  -1414  -1619  -1216  -1526  -1557 
     16 :  -1301  -1600  -1400  -1601  -1500  -1598  -1666 
     17 :  -1564  -1549  -1550  -1573  -1351  -1400  -1300 
     18 :  -1651  -1301  -1528  -1171  -1232  -1276  -1494 
     19 :  -1251  -1444  -1302  -1601  -1459  -1301  -1651 
     20 :  -1333  -1467  -1618  -1051  -1586  -1683  -1426 
     21 :  -1494  -1737  -1558  -1496  -1617  -1417  -1577 
     22 :  -1514  -1369  -1559  -1702  -1666  -1415  -1277 
     23 :  -1380  -1403  -1161  -1431  -1401  -1376  -1484 
     24 :  -1281  -1583  -1167  -1586  -1501  -1801  -1528 
     25 :  -1345  -1174  -1567  -1481  -1456  -1552  -1496 
     26 :  -1362  -1444  -1284  -1469  -1329  -1252  -1517 
     27 :  -1316  -1420  -1301  -1632  -1585  -1721  -1322 
    # Map  BB_TESTMAP  Measured Current
      1 :   -159   -145   -120   -128   -130   -152   -158 
      2 :   -151   -123   -165   -138   -134   -166   -149 
      3 :   -138   -144   -133   -148   -142   -139   -161 
      4 :   -124   -157   -163   -163   -133   -157   -145 
      5 :   -171   -139   -161   -160   -170   -129   -135 
      6 :   -150   -129   -168   -146   -168   -162   -154 
      7 :   -148   -121   -158   -133   -166   -149   -132 
      8 :   -158   -151   -158   -139   -176   -144   -155 
      9 :   -135   -163   -124   -142   -145   -169   -139 
     10 :   -175   -129   -172   -125   -179   -151   -141 
     11 :   -136   -135   -161   -132   -145   -158   -162 
     12 :   -150   -163   -128   -172   -145   -160   -129 
     13 :   -181   -136   -131   -146   -160   -157   -154 
     14 :   -152   -138   -152   -137   -159   -167   -165 
     15 :   -162   -169   -149   -152   -129   -162   -163 
     16 :   -137   -169   -149   -168   -159   -170   -178 
     17 :   -172   -163   -170   -173   -147   -148   -142 
     18 :   -184   -139   -165   -130   -134   -135   -156 
     19 :   -133   -160   -141   -170   -159   -141   -174 
     20 :   -148   -158   -184   -116   -165   -184   -154 
     21 :   -168   -193   -168   -168   -170   -142   -168 
     22 :   -170   -154   -168   -177   -175   -146   -142 
     23 :   -150   -149   -126   -159   -139   -143   -154 
     24 :   -140   -173   -126   -165   -162   -184   -158 
     25 :   -142   -127   -165   -156   -152   -167   -158 
     26 :   -148   -154   -141   -157   -140   -133   -165 
     27 :   -136   -152   -138   -173   -169   -184   -140 
    BigBite thresholds E dE(tdc) dE(trigger)
    Wed May  7 16:11:49 EDT 2008	375	140	280
    Threshold for 'mwdc_back' is +7.504 V  (3072)
    USAGE: ./threshold 
       -g|--get|get             Get threshold for 
       -s|--set|set      Set threshold for  to 
       -v                             Verbose.
       -h                             This help text.
    
         is a voltage in units of mV or V
          is from table below
    
      name           Channel       Range       Description
      -----          -------      -------      -----------
      BB_Cer           7         -1V -- 0V     BB Cerenkov Threshold
      BB_PSh           6         -1V -- 0V     BB Preshower Threshold
      BB_Sh            5         -1V -- 0V     BB Shower Threshold
      mwdc_back        2          0V -- +15V   Back   MWDC Threshold
    
      Using controller IP: bbcamac1.jlab.org.  I/O reg in slot 12
      Using cnaf command:  './cnafb'
    
      Examples:
      ./threshold -g mwdc_back        
    		---> Return thresh for mwdc_back
      ./threshold -s BB_Sh  -200      
    		---> Set thresh for BB_Sh     to -200 mV
      ./threshold -s mwdc_back  100mV 
    		---> Set thresh for mwdc_back to  100 mV
      ./threshold -s mwdc_back  1.0V  
    		---> Set thresh for mwdc_back to  1.0 V