Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 02:28:31 on May 16, 2008
Entry number 238164
keyword=End_of_Run_1142
****************************
Run Number: 1142
End of Run Comment:
Run_type=Calibration,target_type=Tantalum,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=calibration
PRESCALE FACTORS:ps1=1 ps2=16777215 ps3=1 ps4=1000 ps5=1 ps6=65535 ps7=1 ps8=100
EVENTS : [0]: 1010785 [+]: 497088 [-]: 498767
TIME : [0]: 5.132 mins [+]: 2.573 mins [-]: 2.574 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -5.81010 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 91.62% [+]: 91.76% [-]: 91.75%
TRIGGER RATES: PRES/REAL
T1[0] :38979.9/38979.9 Hz T2[0] : 0.0/0.0 Hz T3[0] :177.5/177.5 Hz T4[0] : 3.4/3441.8 Hz T5[0] :14.9/14.9 Hz T6[0] : 0.0/0.0 Hz T7[0] : 1.6/1.6 Hz T8[0] :10.2/1024.0 Hz
T1[+] :38930.2/38930.2 Hz T2[+] : 0.0/0.0 Hz T3[+] :177.3/177.3 Hz T4[+] : 3.4/3437.0 Hz T5[+] :15.1/15.1 Hz T6[+] : 0.0/0.0 Hz T7[+] : 1.2/1.2 Hz T8[+] :10.2/1024.0 Hz
T1[-] :38984.6/38984.6 Hz T2[-] : 0.0/0.0 Hz T3[-] :177.5/177.5 Hz T4[-] : 3.4/3445.7 Hz T5[-] :14.7/14.7 Hz T6[-] : 0.0/0.0 Hz T7[-] : 1.9/1.9 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :12003519/12003519 T2[0] : 0/0 T3[0] : 54670/54670 T4[0] : 1059/1059882 T5[0] : 4576/4576 T6[0] : 0/0 T7[0] : 489/489 T8[0] : 3153/315332
T1[+] :6009348/6009348 T2[+] : 0/0 T3[+] : 27374/27374 T4[+] : 530/530549 T5[+] : 2327/2327 T6[+] : 0/0 T7[+] : 191/191 T8[+] : 1580/158067
T1[-] :6021100/6021100 T2[-] : 0/0 T3[-] : 27412/27412 T4[-] : 532/532187 T5[-] : 2264/2264 T6[-] : 0/0 T7[-] : 296/296 T8[-] : 1581/158155
AVERAGE CURRENT
BCM x1 : 3.7450 uA BCM x3 : 3.7440 uA BCM x10: 3.7758 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -969.9 ppm BCM u3 : -890.3 ppm BCM u10: -870.3 ppm
BCM d1 : -992.7 ppm BCM d3 : -869.1 ppm BCM d10: -869.3 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.001154 BCM u3 [0]:0.001153 BCM u10[0]:0.001161
BCM u1 [+]:0.0005774 BCM u3 [+]:0.0005769 BCM u10[+]:0.0005812
BCM u1 [-]:0.0005788 BCM u3 [-]:0.0005782 BCM u10[-]:0.0005825
BCM d1 [0]:0.001153 BCM d3 [0]:0.001153 BCM d10[0]:0.001164
BCM d1 [+]:0.000577 BCM d3 [+]:0.0005773 BCM d10[+]:0.0005828
BCM d1 [-]:0.0005784 BCM d3 [-]:0.0005786 BCM d10[-]:0.0005842
****************************
End-of-run EPICS data for Run Number 1142 at Fri May 16 02:28:22 EDT 2008
Wien angle : -33.7301
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.628598
Left Arm arm angle : 57.5003
Right Arm D1 momentum : 0.00445235
Right Arm arm angle : 104.999
HALLA:p : 1192.28
HALLA:dpp : -0.000243137
Tiefenbach Hall A energy : 1192.28
Left Arm Top VDC Current : -0.634766
Left Arm Bottom VDC Current : 2.05078
-----
Left Arm Q1 momentum : 0.6286
Left Arm Q1 power supply : 472.915
Left Arm Q1 gauss meter : 0.04057
Left Arm Q2 gauss meter : -0.10721
Left Arm Q2 power supply current : 270.699
Left Arm Q2 momentum : 0.628656
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 208.642
Left Arm D1 momentum : 0.628597
Left Arm D1 NMR : 0.264705
Left Arm Q3 gauss meter : -0.12688
Left Arm Q3 power supply current : 250.26
Left Arm Q3 momentum : 0.628607
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00370626
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -8.84e-05
Right Arm Q2 power supply current : -0.00018487
Right Arm Q2 momentum : -1.97599e-07
Right Arm Q2 gauss meter : -0.0002826
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0278736
Right Arm D1 momentum : 0.00444962
Right Arm D1 NMR : 0.301257
Right Arm Q3 power supply current : 8.96713e-05
Right Arm Q3 momentum : 0.000277063
Right Arm Q3 gauss meter : -0.0002505
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.619
BigBite Gaussmeter readback : 0.5468
-----
Average current of the two cavities : 3.62609
Current on Unser monitor : 16.0056
Current on Upstream bcm : 3.57251
Current on Downstream bcm : 3.67966
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 82.6888
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4616
MBSY1c Bdl : 297839
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.27
Hall A momentum orbit correction (dpp) : -0.000248921
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.27
Hall C energy (hallc_MeV) : 5710.53
Delta(E)/E width (MV_AI_DXWID) : 1.50361
IPM1C12.XPOS : 0.981883
IPM1H04A.XPOS : 1.15722
IPM1H04A.YPOS : 0.881565
IPM1H04B.XPOS : 0.904227
IPM1H04B.YPOS : 1.30361
-----
Left Arm Collimator : 0.871436
HacL_HPE1313A:0_Ch58 : -0.303223
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : -0.355469
-----
Right Arm Collimator : -0.00800781
HacR_HPE1313A:0_Ch58 : -0.574219
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.842773
-----
Wien angle : -33.7301
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -782.27
Wien field : 22.411
Laser attenuation Hall A : 83
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.32547
SLI vert. size mm : 0
SLI y position : 2.38122
-----
Target : Tantalum
fan frequency loop 1 : 0
fan frequency loop 3 : 35.5
Encoder position : 7.47761e+06
Target type : 7.47761e+06
temperature loop 1(1) : 119.99
temperature loop 1(2) : 119.99
temperature loop 1(3) : 119.99
temperature loop 3(1) : 20
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 106.2
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.0424476
HPH H2 loop 3 : 57.1754
-----