Log entry time 02:34:06 on May 16, 2008
Entry number 238166
keyword=End_of_Run_1143
****************************
Run Number: 1143
End of Run Comment:
Run_type=Calibration,target_type=Tantalum,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=calibration
PRESCALE FACTORS:ps1=1 ps2=16777215 ps3=1 ps4=1000 ps5=1 ps6=65535 ps7=1 ps8=100
EVENTS : [0]: 1005991 [+]: 494401 [-]: 496640
TIME : [0]: 4.812 mins [+]: 2.405 mins [-]: 2.405 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.47506 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 90.75% [+]: 90.89% [-]: 90.87%
TRIGGER RATES: PRES/REAL
T1[0] :37486.7/37486.7 Hz T2[0] : 0.0/0.0 Hz T3[0] :173.0/173.0 Hz T4[0] : 3.4/3357.9 Hz T5[0] :14.8/14.8 Hz T6[0] : 0.0/0.0 Hz T7[0] : 1.2/1.2 Hz T8[0] :10.2/1024.0 Hz
T1[+] :37440.6/37440.6 Hz T2[+] : 0.0/0.0 Hz T3[+] :171.8/171.8 Hz T4[+] : 3.4/3354.8 Hz T5[+] :14.4/14.4 Hz T6[+] : 0.0/0.0 Hz T7[+] : 1.1/1.1 Hz T8[+] :10.2/1024.0 Hz
T1[-] :37532.4/37532.4 Hz T2[-] : 0.0/0.0 Hz T3[-] :173.8/173.8 Hz T4[-] : 3.4/3360.3 Hz T5[-] :15.1/15.1 Hz T6[-] : 0.0/0.0 Hz T7[-] : 1.2/1.2 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :10824069/10824069 T2[0] : 0/0 T3[0] : 49957/49957 T4[0] : 969/969588 T5[0] : 4269/4269 T6[0] : 0/0 T7[0] : 343/343 T8[0] : 2956/295674
T1[+] :5403627/5403627 T2[+] : 0/0 T3[+] : 24801/24801 T4[+] : 484/484185 T5[+] : 2085/2085 T6[+] : 0/0 T7[+] : 162/162 T8[+] : 1477/147789
T1[-] :5415036/5415036 T2[-] : 0/0 T3[-] : 25081/25081 T4[-] : 484/484819 T5[-] : 2178/2178 T6[-] : 0/0 T7[-] : 180/180 T8[-] : 1477/147739
AVERAGE CURRENT
BCM x1 : 3.6058 uA BCM x3 : 3.6049 uA BCM x10: 3.6355 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1308 ppm BCM u3 : -1205 ppm BCM u10: -1179 ppm
BCM d1 : -1311 ppm BCM d3 : -1180 ppm BCM d10: -1177 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.001042 BCM u3 [0]:0.001041 BCM u10[0]:0.001048
BCM u1 [+]:0.00052 BCM u3 [+]:0.0005195 BCM u10[+]:0.0005234
BCM u1 [-]:0.0005212 BCM u3 [-]:0.0005206 BCM u10[-]:0.0005245
BCM d1 [0]:0.001041 BCM d3 [0]:0.001041 BCM d10[0]:0.001051
BCM d1 [+]:0.0005194 BCM d3 [+]:0.0005197 BCM d10[+]:0.0005247
BCM d1 [-]:0.0005206 BCM d3 [-]:0.0005208 BCM d10[-]:0.0005258
****************************
End-of-run EPICS data for Run Number 1143 at Fri May 16 02:33:57 EDT 2008
Wien angle : -33.7301
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.628597
Left Arm arm angle : 57.5003
Right Arm D1 momentum : 0.00445671
Right Arm arm angle : 104.999
HALLA:p : 1192.28
HALLA:dpp : -0.000240614
Tiefenbach Hall A energy : 1192.28
Left Arm Top VDC Current : 5.27344
Left Arm Bottom VDC Current : -1.26953
-----
Left Arm Q1 momentum : 0.6286
Left Arm Q1 power supply : 472.862
Left Arm Q1 gauss meter : 0.04057
Left Arm Q2 gauss meter : -0.10724
Left Arm Q2 power supply current : 270.7
Left Arm Q2 momentum : 0.628656
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 208.643
Left Arm D1 momentum : 0.628597
Left Arm D1 NMR : 0.264705
Left Arm Q3 gauss meter : -0.12687
Left Arm Q3 power supply current : 250.261
Left Arm Q3 momentum : 0.628608
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00267762
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -7.05e-05
Right Arm Q2 power supply current : -0.000421503
Right Arm Q2 momentum : -9.79403e-07
Right Arm Q2 gauss meter : -0.0002905
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0295751
Right Arm D1 momentum : 0.00445235
Right Arm D1 NMR : 0.301255
Right Arm Q3 power supply current : 2.98904e-05
Right Arm Q3 momentum : 0.000275384
Right Arm Q3 gauss meter : -0.0002506
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.619
BigBite Gaussmeter readback : 0.5469
-----
Average current of the two cavities : 3.64176
Current on Unser monitor : 16.0136
Current on Upstream bcm : 3.56761
Current on Downstream bcm : 3.71591
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 82.4512
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4616
MBSY1c Bdl : 297839
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.27
Hall A momentum orbit correction (dpp) : -0.000244192
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.27
Hall C energy (hallc_MeV) : 5710.5
Delta(E)/E width (MV_AI_DXWID) : 1.51777
IPM1C12.XPOS : 0.956926
IPM1H04A.XPOS : 1.14611
IPM1H04A.YPOS : 0.851158
IPM1H04B.XPOS : 0.902789
IPM1H04B.YPOS : 1.30713
-----
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.303223
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.355469
-----
Right Arm Collimator : -0.00810547
HacR_HPE1313A:0_Ch58 : -0.575195
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.842285
-----
Wien angle : -33.7301
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -782.27
Wien field : 22.411
Laser attenuation Hall A : 83
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.32547
SLI vert. size mm : 0
SLI y position : 2.35117
-----
Target : Tantalum
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 7.47761e+06
Target type : 7.47761e+06
temperature loop 1(1) : 119.99
temperature loop 1(2) : 119.99
temperature loop 1(3) : 119.99
temperature loop 3(1) : 20
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 105.8
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.0970926
HPH H2 loop 3 : 59.1225
-----