    User name a-onl

    Log entry time 02:49:14 on May 16, 2008

    Entry number 238171

    keyword=End_of_Run_1145
    ****************************
     Run Number: 1145
     End of Run Comment:
    Run_type=Calibration,target_type=Tantalum,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=calibration
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=1000   ps5=1   ps6=65535   ps7=1   ps8=100   
    
    EVENTS   : [0]: 1004483      [+]: 494404       [-]: 495144       
    TIME     : [0]: 10.032 mins  [+]: 4.976 mins  [-]: 4.974 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.64567 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  31.74%      [+]:  32.21%      [-]:  32.28%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :2273.2/2273.2 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :169.7/169.7 Hz   T4[0] : 3.3/3290.6 Hz   T5[0] :13.2/13.2 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 2.1/2.1  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :2272.0/2272.0 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :169.6/169.6 Hz   T4[+] : 3.3/3286.2 Hz   T5[+] :13.1/13.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 1.5/1.5  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :2277.1/2277.1 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :170.0/170.0 Hz   T4[-] : 3.3/3297.1 Hz   T5[-] :13.3/13.3 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 2.8/2.8  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1368258/1368258  T2[0] :      0/0        T3[0] : 102166/102166   T4[0] :   1980/1980616  T5[0] :   7946/7946     T6[0] :      0/0        T7[0] :   1284/1284     T8[0] :   6163/616347   
    T1[+] : 678289/678289   T2[+] :      0/0        T3[+] :  50635/50635    T4[+] :    981/981100   T5[+] :   3922/3922     T6[+] :      0/0        T7[+] :    452/452      T8[+] :   3057/305714   
    T1[-] : 679580/679580   T2[-] :      0/0        T3[-] :  50743/50743    T4[-] :    984/984002   T5[-] :   3960/3960     T6[-] :      0/0        T7[-] :    844/844      T8[-] :   3056/305609   
    
    AVERAGE CURRENT
    BCM x1 : 3.4703 uA  BCM x3 : 3.4692 uA  BCM x10: 3.4985 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1333 ppm     BCM u3 :    -1241 ppm     BCM u10:    -1219 ppm     
    BCM d1 :    -1355 ppm     BCM d3 :    -1224 ppm     BCM d10:    -1216 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.00209        BCM u3 [0]:0.002088       BCM u10[0]:0.002104       
    BCM u1 [+]:0.001036       BCM u3 [+]:0.001035       BCM u10[+]:0.001043       
    BCM u1 [-]:0.001039       BCM u3 [-]:0.001037       BCM u10[-]:0.001045       
    
    BCM d1 [0]:0.002087       BCM d3 [0]:0.002088       BCM d10[0]:0.002108       
    BCM d1 [+]:0.001035       BCM d3 [+]:0.001035       BCM d10[+]:0.001045       
    BCM d1 [-]:0.001037       BCM d3 [-]:0.001037       BCM d10[-]:0.001047       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1145 at Fri May 16 02:49:05 EDT 2008
    
    Wien angle : -33.7301
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.628598
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00445671
    Right Arm arm angle : 104.999
    HALLA:p : 1192.2
    HALLA:dpp : -0.000308904
    Tiefenbach Hall A energy : 1192.2
    Left Arm Top VDC Current : 3.4668
    Left Arm Bottom VDC Current : 1.31836
    -----
    Left Arm Q1 momentum : 0.6286
    Left Arm Q1 power supply : 472.915
    Left Arm Q1 gauss meter : 0.04056
    Left Arm Q2 gauss meter : -0.1072
    Left Arm Q2 power supply current : 270.698
    Left Arm Q2 momentum : 0.628655
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 208.641
    Left Arm D1 momentum : 0.628598
    Left Arm D1 NMR : 0.264705
    Left Arm Q3 gauss meter : -0.12687
    Left Arm Q3 power supply current : 250.258
    Left Arm Q3 momentum : 0.628604
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00389183
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.34e-05
    Right Arm Q2 power supply current : -0.000136804
    Right Arm Q2 momentum : -3.17876e-07
    Right Arm Q2 gauss meter : -0.0002784
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0271923
    Right Arm D1 momentum : 0.00445289
    Right Arm D1 NMR : 0.301258
    Right Arm Q3 power supply current : 7.09898e-05
    Right Arm Q3 momentum : 0.000272025
    Right Arm Q3 gauss meter : -0.0002511
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.547
    -----
    Average current of the two cavities : 3.81731
    Current on Unser monitor : 17.3105
    Current on Upstream bcm : 3.7504
    Current on Downstream bcm : 3.88423
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 82.3373
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4616
    MBSY1c Bdl : 297839
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.36
    Hall A momentum orbit correction (dpp) : -0.000171655
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.36
    Hall C energy (hallc_MeV) : 5710.45
    Delta(E)/E width (MV_AI_DXWID) : 1.37313
    IPM1C12.XPOS : 0.58562
    IPM1H04A.XPOS : 1.15724
    IPM1H04A.YPOS : 0.875482
    IPM1H04B.XPOS : 0.899037
    IPM1H04B.YPOS : 1.31286
    -----
    Left Arm Collimator : 0.871484
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.355469
    -----
    Right Arm Collimator : -0.00869141
    HacR_HPE1313A:0_Ch58 : -0.575684
    HacR_HPE1313A:0_Ch55 : 21.9238
    HacR_HPE1313A:0_Ch54 : -0.842285
    -----
    Wien angle : -33.7301
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -782.27
    Wien field : 22.411
    Laser attenuation Hall A : 86
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.32547
    SLI vert. size mm : 0
    SLI y position : 2.3662
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 35.5
    Encoder position : 7.47761e+06
    Target type : 7.47761e+06
    temperature loop 1(1) : 119.99
    temperature loop 1(2) : 119.99
    temperature loop 1(3) : 119.99
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 105.1
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 56.4056
    -----