keyword=End_of_Run_1146
****************************
Run Number: 1146
End of Run Comment:
Run_type=Calibration,target_type=Tantalum,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=calibration
PRESCALE FACTORS:ps1=1 ps2=16777215 ps3=1 ps4=1000 ps5=1 ps6=65535 ps7=1 ps8=100
EVENTS : [0]: 422721 [+]: 207813 [-]: 208776
TIME : [0]: 4.123 mins [+]: 2.072 mins [-]: 2.071 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -5.23753 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 31.22% [+]: 31.72% [-]: 31.60%
TRIGGER RATES: PRES/REAL
T1[0] :2305.4/2305.4 Hz T2[0] : 0.0/0.0 Hz T3[0] :178.3/178.3 Hz T4[0] : 3.5/3493.6 Hz T5[0] :13.2/13.2 Hz T6[0] : 0.0/0.0 Hz T7[0] : 1.0/1.0 Hz T8[0] :10.2/1024.0 Hz
T1[+] :2268.7/2268.7 Hz T2[+] : 0.0/0.0 Hz T3[+] :178.1/178.1 Hz T4[+] : 3.5/3489.7 Hz T5[+] :13.2/13.2 Hz T6[+] : 0.0/0.0 Hz T7[+] : 0.8/0.8 Hz T8[+] :10.2/1024.0 Hz
T1[-] :2276.4/2276.4 Hz T2[-] : 0.0/0.0 Hz T3[-] :178.4/178.4 Hz T4[-] : 3.5/3496.5 Hz T5[-] :13.3/13.3 Hz T6[-] : 0.0/0.0 Hz T7[-] : 1.3/1.3 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 570231/570231 T2[0] : 0/0 T3[0] : 44095/44095 T4[0] : 864/864135 T5[0] : 3274/3274 T6[0] : 0/0 T7[0] : 253/253 T8[0] : 2532/253287
T1[+] : 282084/282084 T2[+] : 0/0 T3[+] : 22150/22150 T4[+] : 433/433891 T5[+] : 1642/1642 T6[+] : 0/0 T7[+] : 99/99 T8[+] : 1273/127320
T1[-] : 282904/282904 T2[-] : 0/0 T3[-] : 22165/22165 T4[-] : 434/434525 T5[-] : 1647/1647 T6[-] : 0/0 T7[-] : 162/162 T8[-] : 1272/127257
AVERAGE CURRENT
BCM x1 : 3.7978 uA BCM x3 : 3.7968 uA BCM x10: 3.8291 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1365 ppm BCM u3 : -1282 ppm BCM u10: -1258 ppm
BCM d1 : -1374 ppm BCM d3 : -1266 ppm BCM d10: -1254 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.0009399 BCM u3 [0]:0.000939 BCM u10[0]:0.0009459
BCM u1 [+]:0.0004718 BCM u3 [+]:0.0004714 BCM u10[+]:0.0004748
BCM u1 [-]:0.0004728 BCM u3 [-]:0.0004723 BCM u10[-]:0.0004758
BCM d1 [0]:0.0009389 BCM d3 [0]:0.0009393 BCM d10[0]:0.0009484
BCM d1 [+]:0.0004713 BCM d3 [+]:0.0004716 BCM d10[+]:0.0004761
BCM d1 [-]:0.0004724 BCM d3 [-]:0.0004725 BCM d10[-]:0.0004771
****************************
End-of-run EPICS data for Run Number 1146 at Fri May 16 02:53:57 EDT 2008
Wien angle : -33.7301
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.628597
Left Arm arm angle : 57.5003
Right Arm D1 momentum : 0.00446815
Right Arm arm angle : 104.999
HALLA:p : 1192.27
HALLA:dpp : -0.000249264
Tiefenbach Hall A energy : 1192.27
Left Arm Top VDC Current : 2.44141
Left Arm Bottom VDC Current : -1.36719
-----
Left Arm Q1 momentum : 0.6286
Left Arm Q1 power supply : 472.915
Left Arm Q1 gauss meter : 0.04056
Left Arm Q2 gauss meter : -0.10719
Left Arm Q2 power supply current : 270.699
Left Arm Q2 momentum : 0.628656
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 208.638
Left Arm D1 momentum : 0.628598
Left Arm D1 NMR : 0.264705
Left Arm Q3 gauss meter : -0.12689
Left Arm Q3 power supply current : 250.259
Left Arm Q3 momentum : 0.628604
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00339343
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -9.23e-05
Right Arm Q2 power supply current : -0.000166383
Right Arm Q2 momentum : 0.0011942
Right Arm Q2 gauss meter : -0.0002864
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0264545
Right Arm D1 momentum : 0.00446815
Right Arm D1 NMR : 0.301258
Right Arm Q3 power supply current : 7.84624e-05
Right Arm Q3 momentum : -1.69017e-07
Right Arm Q3 gauss meter : -0.0002511
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.619
BigBite Gaussmeter readback : 0.5466
-----
Average current of the two cavities : 3.82702
Current on Unser monitor : 17.6067
Current on Upstream bcm : 3.7639
Current on Downstream bcm : 3.89015
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 82.3468
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4616
MBSY1c Bdl : 297839
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.28
Hall A momentum orbit correction (dpp) : -0.000239118
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.28
Hall C energy (hallc_MeV) : 5710.51
Delta(E)/E width (MV_AI_DXWID) : 1.41971
IPM1C12.XPOS : 0.963639
IPM1H04A.XPOS : 1.15478
IPM1H04A.YPOS : 0.843305
IPM1H04B.XPOS : 0.907493
IPM1H04B.YPOS : 1.30143
-----
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.303223
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.35498
-----
Right Arm Collimator : -0.00859375
HacR_HPE1313A:0_Ch58 : -0.575195
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.842285
-----
Wien angle : -33.7301
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -782.27
Wien field : 22.411
Laser attenuation Hall A : 86
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.32547
SLI vert. size mm : 0
SLI y position : 2.38122
-----
Target : Tantalum
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 7.47761e+06
Target type : 7.47761e+06
temperature loop 1(1) : 119.99
temperature loop 1(2) : 119.99
temperature loop 1(3) : 119.99
temperature loop 3(1) : 20
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 104.9
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.174027
HPH H2 loop 3 : 59.1225
-----