     Run Number: 1149
     End of Run Comment:
    Run_type=Calibration,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=checking BigBite
     FPP HV= 1770
    
    PRESCALE FACTORS:ps1=60000   ps2=16777215   ps3=1   ps4=1000   ps5=1   ps6=65535   ps7=1   ps8=100   
    
    EVENTS   : [0]: 1004082      [+]: 494636       [-]: 494588       
    TIME     : [0]: 12.085 mins  [+]: 5.995 mins  [-]: 5.995 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -5.80500 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  37.88%      [+]:  38.30%      [-]:  38.35%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 8.7/522958.9 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :2201.8/2201.8 Hz   T4[0] : 8.5/8469.1 Hz   T5[0] :1495.7/1495.7 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 2.4/2.4  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] : 8.7/522834.4 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :2201.7/2201.7 Hz   T4[+] : 8.5/8467.1 Hz   T5[+] :1496.1/1496.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 2.4/2.4  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] : 8.7/523891.0 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :2202.9/2202.9 Hz   T4[-] : 8.5/8477.9 Hz   T5[-] :1495.9/1495.9 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 2.5/2.5  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   6319/379189625  T2[0] :      0/0        T3[0] :1596496/1596496  T4[0] :   6140/6140829  T5[0] :1084537/1084537  T6[0] :      0/0        T7[0] :   1762/1762     T8[0] :   7424/742487   
    T1[+] :   3134/188049341  T2[+] :      0/0        T3[+] : 791883/791883   T4[+] :   3045/3045402  T5[+] : 538103/538103   T6[+] :      0/0        T7[+] :    848/848      T8[+] :   3683/368305   
    T1[-] :   3140/188447284  T2[-] :      0/0        T3[-] : 792391/792391   T4[-] :   3049/3049556  T5[-] : 538096/538096   T6[-] :      0/0        T7[-] :    889/889      T8[-] :   3683/368340   
    
    AVERAGE CURRENT
    BCM x1 : 3.2450 uA  BCM x3 : 3.2439 uA  BCM x10: 3.2713 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1153 ppm     BCM u3 :    -1039 ppm     BCM u10:    -1015 ppm     
    BCM d1 :    -1178 ppm     BCM d3 :    -1016 ppm     BCM d10:    -1010 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.002354       BCM u3 [0]:0.002351       BCM u10[0]:0.002368       
    BCM u1 [+]:0.001167       BCM u3 [+]:0.001166       BCM u10[+]:0.001174       
    BCM u1 [-]:0.00117        BCM u3 [-]:0.001168       BCM u10[-]:0.001177       
    
    BCM d1 [0]:0.002352       BCM d3 [0]:0.002353       BCM d10[0]:0.002376       
    BCM d1 [+]:0.001166       BCM d3 [+]:0.001167       BCM d10[+]:0.001178       
    BCM d1 [-]:0.001169       BCM d3 [-]:0.001169       BCM d10[-]:0.00118        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1149 at Fri May 16 04:01:08 EDT 2008
    
    Wien angle : -33.7301
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.628597
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00445099
    Right Arm arm angle : 104.999
    HALLA:p : 1192.57
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.57
    Left Arm Top VDC Current : -0.78125
    Left Arm Bottom VDC Current : 4.05273
    -----
    Left Arm Q1 momentum : 0.628529
    Left Arm Q1 power supply : 472.862
    Left Arm Q1 gauss meter : 0.04056
    Left Arm Q2 gauss meter : -0.1072
    Left Arm Q2 power supply current : 270.699
    Left Arm Q2 momentum : 0.628655
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 208.64
    Left Arm D1 momentum : 0.628597
    Left Arm D1 NMR : 0.264705
    Left Arm Q3 gauss meter : -0.12692
    Left Arm Q3 power supply current : 250.346
    Left Arm Q3 momentum : 0.628823
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00246554
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -6.65e-05
    Right Arm Q2 power supply current : -0.000321673
    Right Arm Q2 momentum : -6.01388e-07
    Right Arm Q2 gauss meter : -0.0002876
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0273371
    Right Arm D1 momentum : 0.00445099
    Right Arm D1 NMR : 0.30125
    Right Arm Q3 power supply current : 9.34076e-05
    Right Arm Q3 momentum : 0.000265868
    Right Arm Q3 gauss meter : -0.0002525
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.5471
    -----
    Average current of the two cavities : 0.0237194
    Current on Unser monitor : 13.6169
    Current on Upstream bcm : 0.0354148
    Current on Downstream bcm : 0.012024
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.00832941
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4616
    MBSY1c Bdl : 297839
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.3
    Hall A momentum orbit correction (dpp) : -0.000222809
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.3
    Hall C energy (hallc_MeV) : 5710.53
    Delta(E)/E width (MV_AI_DXWID) : 1.46246
    IPM1C12.XPOS : 0.968447
    IPM1H04A.XPOS : 1.14712
    IPM1H04A.YPOS : 0.825685
    IPM1H04B.XPOS : 0.896037
    IPM1H04B.YPOS : 1.26948
    -----
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.354492
    -----
    Right Arm Collimator : -0.00830078
    HacR_HPE1313A:0_Ch58 : -0.575684
    HacR_HPE1313A:0_Ch55 : 21.9727
    HacR_HPE1313A:0_Ch54 : -0.842285
    -----
    Wien angle : -33.7301
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -782.27
    Wien field : 22.411
    Laser attenuation Hall A : 80
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.6236
    SLI vert. size mm : 0
    SLI y position : 0.923944
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 113.02
    temperature loop 1(2) : 112.45
    temperature loop 1(3) : 119.99
    temperature loop 3(1) : 19.99
    temperature loop 3(2) : 19.98
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 102.8
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0540192
    HPH H2 loop 3 : 92.2415
    -----