    End-of-run EPICS data for Run Number 1151 at Fri May 16 04:13:55 EDT 2008
    
    Wien angle : -33.7301
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.628598
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00444826
    Right Arm arm angle : 104.999
    HALLA:p : 1192.57
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.57
    Left Arm Top VDC Current : 4.39453
    Left Arm Bottom VDC Current : -0.488281
    -----
    Left Arm Q1 momentum : 0.6286
    Left Arm Q1 power supply : 472.915
    Left Arm Q1 gauss meter : 0.04055
    Left Arm Q2 gauss meter : -0.10718
    Left Arm Q2 power supply current : 270.7
    Left Arm Q2 momentum : 0.628658
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 208.641
    Left Arm D1 momentum : 0.628598
    Left Arm D1 NMR : 0.264705
    Left Arm Q3 gauss meter : -0.12677
    Left Arm Q3 power supply current : 250.019
    Left Arm Q3 momentum : 0.628012
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00302227
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -6.79e-05
    Right Arm Q2 power supply current : -0.000114619
    Right Arm Q2 momentum : -2.66329e-07
    Right Arm Q2 gauss meter : -0.0002876
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.026857
    Right Arm D1 momentum : 0.00445943
    Right Arm D1 NMR : 0.301253
    Right Arm Q3 power supply current : -3.36267e-05
    Right Arm Q3 momentum : -8.45087e-08
    Right Arm Q3 gauss meter : -0.000253
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.547
    -----
    Average current of the two cavities : 0.0236861
    Current on Unser monitor : 13.0551
    Current on Upstream bcm : 0.0354693
    Current on Downstream bcm : 0.0119028
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.0063777
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4616
    MBSY1c Bdl : 297839
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.57
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.57
    Hall C energy (hallc_MeV) : 5710.72
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 :
    -----
    Right Arm Collimator : -0.0081543
    HacR_HPE1313A:0_Ch58 : -0.574707
    HacR_HPE1313A:0_Ch55 : 21.875
    HacR_HPE1313A:0_Ch54 : -0.842285
    -----
    Wien angle : -33.7301
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -782.27
    Wien field : 22.411
    Laser attenuation Hall A : 85
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? :
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.61118
    SLI vert. size mm : 0
    SLI y position : 1.99812
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 111.87
    temperature loop 1(2) : 111.31
    temperature loop 1(3) : 119.27
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.98
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 102.5
    Heat exchange LH2 : 20
    HPH H2 loop 1 :
    HPH H2 loop 3 : 91.7516
    -----