Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 04:14:47 on May 16, 2008
Entry number 238190
keyword=End_of_Run_1151
****************************
Run Number: 1151
End of Run Comment:
Run_type=Calibration,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=checking FPP HV=1800 V
Junk run
PRESCALE FACTORS:ps1=60000 ps2=16777215 ps3=1 ps4=1000 ps5=1 ps6=65535 ps7=1 ps8=100
EVENTS : [0]: 2135 [+]: 1048 [-]: 1054
TIME : [0]: 0.366 mins [+]: 0.245 mins [-]: 0.245 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -7.89431 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 5.76% [+]: 32.81% [-]: 28.71%
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/96.2 Hz T2[0] : 0.0/0.0 Hz T3[0] :84.6/84.6 Hz T4[0] : 1.3/1334.5 Hz T5[0] :12.5/12.5 Hz T6[0] : 0.0/0.0 Hz T7[0] : 7.0/7.0 Hz T8[0] :10.2/1024.0 Hz
T1[+] : 0.0/349.8 Hz T2[+] : 0.0/0.0 Hz T3[+] :85.4/85.4 Hz T4[+] : 1.3/1325.8 Hz T5[+] :13.3/13.3 Hz T6[+] : 0.0/0.0 Hz T7[+] : 9.1/9.1 Hz T8[+] :10.2/1024.0 Hz
T1[-] : 0.0/94.8 Hz T2[-] : 0.0/0.0 Hz T3[-] :85.1/85.1 Hz T4[-] : 1.3/1321.9 Hz T5[-] :12.3/12.3 Hz T6[-] : 0.0/0.0 Hz T7[-] : 4.0/4.0 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/2115 T2[0] : 0/0 T3[0] : 1860/1860 T4[0] : 29/29334 T5[0] : 274/274 T6[0] : 0/0 T7[0] : 153/153 T8[0] : 225/22509
T1[+] : 0/5146 T2[+] : 0/0 T3[+] : 1257/1257 T4[+] : 19/19504 T5[+] : 196/196 T6[+] : 0/0 T7[+] : 134/134 T8[+] : 150/15064
T1[-] : 0/1393 T2[-] : 0/0 T3[-] : 1251/1251 T4[-] : 19/19424 T5[-] : 181/181 T6[-] : 0/0 T7[-] : 59/59 T8[-] : 150/15047
AVERAGE CURRENT
BCM x1 : 0.0030 uA BCM x3 : -0.0001uA BCM x10: -0.0010uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :7.853E+04 ppm BCM u3 :1.881E+05 ppm BCM u10:3.651E+05 ppm
BCM d1 :-4.281E+05 ppm BCM d3 : 1E+39 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:1.394E-07 BCM u3 [0]:1.825E-08 BCM u10[0]:1.246E-08
BCM u1 [+]:1.063E-07 BCM u3 [+]:2.21E-08 BCM u10[+]:1.944E-08
BCM u1 [-]:9.075E-08 BCM u3 [-]:1.509E-08 BCM u10[-]:9.031E-09
BCM d1 [0]:-5.861E-09 BCM d3 [0]:-2.142E-08 BCM d10[0]:-5.524E-08
BCM d1 [+]:7.327E-10 BCM d3 [+]:-5.97E-09 BCM d10[+]:-2.524E-08
BCM d1 [-]:1.827E-09 BCM d3 [-]:-1.194E-08 BCM d10[-]:-3.646E-08
****************************
End-of-run EPICS data for Run Number 1151 at Fri May 16 04:14:38 EDT 2008
Wien angle : -33.7301
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.628598
Left Arm arm angle : 57.5003
Right Arm D1 momentum : 0.00444172
Right Arm arm angle : 104.999
HALLA:p : 1192.57
HALLA:dpp : 0
Tiefenbach Hall A energy : 1192.57
Left Arm Top VDC Current : 5.22461
Left Arm Bottom VDC Current : 4.3457
-----
Left Arm Q1 momentum : 0.6286
Left Arm Q1 power supply : 472.915
Left Arm Q1 gauss meter : 0.04056
Left Arm Q2 gauss meter : -0.10724
Left Arm Q2 power supply current : 270.701
Left Arm Q2 momentum : 0.628659
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 208.642
Left Arm D1 momentum : 0.628598
Left Arm D1 NMR : 0.264705
Left Arm Q3 gauss meter : -0.12708
Left Arm Q3 power supply current : 250.635
Left Arm Q3 momentum : 0.629549
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00407211
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -8.7e-05
Right Arm Q2 power supply current : -0.000122014
Right Arm Q2 momentum : -1.80416e-07
Right Arm Q2 gauss meter : -0.0002791
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0260803
Right Arm D1 momentum : 0.00444172
Right Arm D1 NMR : 0.301254
Right Arm Q3 power supply current : -3.7363e-06
Right Arm Q3 momentum : 0.000264749
Right Arm Q3 gauss meter : -0.0002529
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.619
BigBite Gaussmeter readback : 0.5472
-----
Average current of the two cavities : 0.0237823
Current on Unser monitor : 13.8243
Current on Upstream bcm : 0.0355924
Current on Downstream bcm : 0.0119723
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00540523
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4616
MBSY1c Bdl : 297839
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.57
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.57
Hall C energy (hallc_MeV) : 5710.72
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.303223
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.354492
-----
Right Arm Collimator : -0.00864258
HacR_HPE1313A:0_Ch58 : -0.575684
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.842285
-----
Wien angle : -33.7301
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -782.27
Wien field : 22.411
Laser attenuation Hall A : 85
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.61615
SLI vert. size mm : 0
SLI y position : 2.01315
-----
Target : L3 6cm
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 2.06493e+07
Target type : 2.06493e+07
temperature loop 1(1) : 111.83
temperature loop 1(2) : 111.27
temperature loop 1(3) : 119.46
temperature loop 3(1) : 20
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 102.5
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.0669839
HPH H2 loop 3 : 89.8053
-----