Log entry time 05:27:52 on May 16, 2008
Entry number 238202
keyword=End_of_Run_1156
****************************
Run Number: 1156
End of Run Comment:
Run_type=Calibration,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=checking FPP HV=1800 V
PRESCALE FACTORS:ps1=60000 ps2=16777215 ps3=1 ps4=1000 ps5=1 ps6=65535 ps7=1 ps8=100
EVENTS : [0]: 1004945 [+]: 493990 [-]: 496102
TIME : [0]: 10.569 mins [+]: 5.241 mins [-]: 5.241 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.85149 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 37.67% [+]: 38.10% [-]: 38.08%
TRIGGER RATES: PRES/REAL
T1[0] : 1.0/58292.8 Hz T2[0] : 0.0/0.0 Hz T3[0] :2522.2/2522.2 Hz T4[0] : 9.6/9600.5 Hz T5[0] :716.4/716.4 Hz T6[0] : 0.0/0.0 Hz T7[0] : 2.3/2.3 Hz T8[0] :10.2/1024.0 Hz
T1[+] : 1.0/57849.3 Hz T2[+] : 0.0/0.0 Hz T3[+] :2518.4/2518.4 Hz T4[+] : 9.6/9580.9 Hz T5[+] :708.6/708.6 Hz T6[+] : 0.0/0.0 Hz T7[+] : 1.6/1.6 Hz T8[+] :10.2/1024.0 Hz
T1[-] : 1.0/58026.7 Hz T2[-] : 0.0/0.0 Hz T3[-] :2527.1/2527.1 Hz T4[-] : 9.6/9626.0 Hz T5[-] :714.4/714.4 Hz T6[-] : 0.0/0.0 Hz T7[-] : 2.9/2.9 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 616/36964188 T2[0] : 0/0 T3[0] :1599362/1599362 T4[0] : 6087/6087811 T5[0] : 454256/454256 T6[0] : 0/0 T7[0] : 1436/1436 T8[0] : 6493/649331
T1[+] : 303/18190765 T2[+] : 0/0 T3[+] : 791921/791921 T4[+] : 3012/3012731 T5[+] : 222833/222833 T6[+] : 0/0 T7[+] : 510/510 T8[+] : 3219/321998
T1[-] : 304/18246507 T2[-] : 0/0 T3[-] : 794645/794645 T4[-] : 3026/3026901 T5[-] : 224631/224631 T6[-] : 0/0 T7[-] : 898/898 T8[-] : 3219/321997
AVERAGE CURRENT
BCM x1 : 3.7250 uA BCM x3 : 3.7242 uA BCM x10: 3.7556 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1421 ppm BCM u3 : -1335 ppm BCM u10: -1321 ppm
BCM d1 : -1449 ppm BCM d3 : -1325 ppm BCM d10: -1317 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.002364 BCM u3 [0]:0.002362 BCM u10[0]:0.002379
BCM u1 [+]:0.001171 BCM u3 [+]:0.00117 BCM u10[+]:0.001178
BCM u1 [-]:0.001174 BCM u3 [-]:0.001173 BCM u10[-]:0.001182
BCM d1 [0]:0.00236 BCM d3 [0]:0.002361 BCM d10[0]:0.002384
BCM d1 [+]:0.001169 BCM d3 [+]:0.00117 BCM d10[+]:0.001181
BCM d1 [-]:0.001172 BCM d3 [-]:0.001173 BCM d10[-]:0.001184
****************************
End-of-run EPICS data for Run Number 1156 at Fri May 16 05:27:43 EDT 2008
Wien angle : -33.7301
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.628596
Left Arm arm angle : 57.5003
Right Arm D1 momentum : 0.00442782
Right Arm arm angle : 104.999
HALLA:p : 1192.27
HALLA:dpp : -0.000248765
Tiefenbach Hall A energy : 1192.28
Left Arm Top VDC Current : 4.93164
Left Arm Bottom VDC Current : -1.17188
-----
Left Arm Q1 momentum : 0.6286
Left Arm Q1 power supply : 472.915
Left Arm Q1 gauss meter : 0.04056
Left Arm Q2 gauss meter : -0.1072
Left Arm Q2 power supply current : 270.698
Left Arm Q2 momentum : 0.628653
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 208.641
Left Arm D1 momentum : 0.628596
Left Arm D1 NMR : 0.264705
Left Arm Q3 gauss meter : -0.1269
Left Arm Q3 power supply current : 250.307
Left Arm Q3 momentum : 0.628725
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00411983
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -9.77e-05
Right Arm Q2 power supply current : -8.87375e-05
Right Arm Q2 momentum : -2.0619e-07
Right Arm Q2 gauss meter : -0.0002858
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0252578
Right Arm D1 momentum : 0.00442782
Right Arm D1 NMR : 0.301245
Right Arm Q3 power supply current : 7.09898e-05
Right Arm Q3 momentum : 0.000254114
Right Arm Q3 gauss meter : -0.0002541
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.619
BigBite Gaussmeter readback : 0.5473
-----
Average current of the two cavities : 3.90994
Current on Unser monitor : 17.5774
Current on Upstream bcm : 3.85108
Current on Downstream bcm : 3.96879
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 97.7905
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4616
MBSY1c Bdl : 297839
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.29
Hall A momentum orbit correction (dpp) : -0.000234875
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.29
Hall C energy (hallc_MeV) : 5710.51
Delta(E)/E width (MV_AI_DXWID) : 1.42317
IPM1C12.XPOS : 0.950822
IPM1H04A.XPOS : 1.15522
IPM1H04A.YPOS : 0.854189
IPM1H04B.XPOS : 0.908887
IPM1H04B.YPOS : 1.29849
-----
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.302734
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.354492
-----
Right Arm Collimator : -0.00864258
HacR_HPE1313A:0_Ch58 : -0.574707
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.842773
-----
Wien angle : -33.7301
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -782.27
Wien field : 22.411
Laser attenuation Hall A : 88
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.32547
SLI vert. size mm : 0
SLI y position : 2.35117
-----
Target : L3 6cm
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 2.06493e+07
Target type : 2.06493e+07
temperature loop 1(1) : 107.36
temperature loop 1(2) : 106.88
temperature loop 1(3) : 112.06
temperature loop 3(1) : 20
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 101
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.0970926
HPH H2 loop 3 : 83.1576
-----