    Log entry time 05:35:26 on May 16, 2008

    Entry number 238204

    keyword=End_of_Run_1157
    ****************************
     Run Number: 1157
     End of Run Comment:
    Run_type=Calibration,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=checking FPP HV=1800 V
     
    
    PRESCALE FACTORS:ps1=3000   ps2=16777215   ps3=1   ps4=1000   ps5=1   ps6=65535   ps7=1   ps8=100   
    
    EVENTS   : [0]: 250470       [+]: 122860       [-]: 123895       
    TIME     : [0]: 5.272 mins  [+]: 2.630 mins  [-]: 2.632 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.44631 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  36.06%      [+]:  36.02%      [-]:  36.23%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :50.3/151010.6 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :1172.5/1172.5 Hz   T4[0] : 5.0/5035.8 Hz   T5[0] :660.0/660.0 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 1.7/1.7  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :49.7/148967.6 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :1151.8/1151.8 Hz   T4[+] : 5.0/4970.0 Hz   T5[+] :648.9/648.9 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 1.6/1.6  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :49.7/149218.6 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :1165.1/1165.1 Hz   T4[-] : 5.0/5007.0 Hz   T5[-] :654.0/654.0 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 1.7/1.7  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  15923/47770832  T2[0] :      0/0        T3[0] : 370916/370916   T4[0] :   1593/1593041  T5[0] : 208775/208775   T6[0] :      0/0        T7[0] :    522/522      T8[0] :   3239/323933   
    T1[+] :   7836/23509963  T2[+] :      0/0        T3[+] : 181774/181774   T4[+] :    784/784357   T5[+] : 102408/102408   T6[+] :      0/0        T7[+] :    252/252      T8[+] :   1616/161607   
    T1[-] :   7854/23564007  T2[-] :      0/0        T3[-] : 183989/183989   T4[-] :    790/790680   T5[-] : 103277/103277   T6[-] :      0/0        T7[-] :    266/266      T8[-] :   1617/161706   
    
    AVERAGE CURRENT
    BCM x1 : 1.6664 uA  BCM x3 : 1.6643 uA  BCM x10: 1.6773 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1231 ppm     BCM u3 :    -1092 ppm     BCM u10:    -1046 ppm     
    BCM d1 :    -1354 ppm     BCM d3 :    -1092 ppm     BCM d10:    -1050 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0005282      BCM u3 [0]:0.0005266      BCM u10[0]:0.0005301      
    BCM u1 [+]:0.0002598      BCM u3 [+]:0.0002591      BCM u10[+]:0.0002608      
    BCM u1 [-]:0.0002606      BCM u3 [-]:0.0002598      BCM u10[-]:0.0002615      
    
    BCM d1 [0]:0.0005262      BCM d3 [0]:0.0005263      BCM d10[0]:0.0005311      
    BCM d1 [+]:0.0002588      BCM d3 [+]:0.0002589      BCM d10[+]:0.0002613      
    BCM d1 [-]:0.0002596      BCM d3 [-]:0.0002596      BCM d10[-]:0.000262       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1157 at Fri May 16 05:35:17 EDT 2008
    
    Wien angle : -33.7301
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.628597
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00440683
    Right Arm arm angle : 104.999
    HALLA:p : 1192.57
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.57
    Left Arm Top VDC Current : -2.14844
    Left Arm Bottom VDC Current : -1.07422
    -----
    Left Arm Q1 momentum : 0.6286
    Left Arm Q1 power supply : 472.915
    Left Arm Q1 gauss meter : 0.04056
    Left Arm Q2 gauss meter : -0.10719
    Left Arm Q2 power supply current : 270.699
    Left Arm Q2 momentum : 0.628655
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 208.639
    Left Arm D1 momentum : 0.628597
    Left Arm D1 NMR : 0.264705
    Left Arm Q3 gauss meter : -0.1269
    Left Arm Q3 power supply current : 250.309
    Left Arm Q3 momentum : 0.62873
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00419406
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -8.71e-05
    Right Arm Q2 power supply current : -0.000266212
    Right Arm Q2 momentum : -6.1857e-07
    Right Arm Q2 gauss meter : -0.0002918
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0280254
    Right Arm D1 momentum : 0.00440057
    Right Arm D1 NMR : 0.301247
    Right Arm Q3 power supply current : 7.47261e-06
    Right Arm Q3 momentum : 0.000255793
    Right Arm Q3 gauss meter : -0.0002546
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.5475
    -----
    Average current of the two cavities : 0.0236765
    Current on Unser monitor : 13.977
    Current on Upstream bcm : 0.0354789
    Current on Downstream bcm : 0.0118741
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.00330837
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4616
    MBSY1c Bdl : 297839
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.57
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.57
    Hall C energy (hallc_MeV) : 5710.72
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.302734
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : -0.354004
    -----
    Right Arm Collimator : -0.00869141
    HacR_HPE1313A:0_Ch58 : -0.575195
    HacR_HPE1313A:0_Ch55 : 21.9238
    HacR_HPE1313A:0_Ch54 : -0.842773
    -----
    Wien angle : -33.7301
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -782.27
    Wien field : 22.411
    Laser attenuation Hall A : 95
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.87081
    SLI vert. size mm : 0
    SLI y position : 1.99812
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 106.96
    temperature loop 1(2) : 106.46
    temperature loop 1(3) : 112.07
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 100.8
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 91.7516
    -----