    User name a-onl

    Log entry time 06:00:15 on May 16, 2008

    Entry number 238207

    keyword=End_of_Run_1158
    ****************************
     Run Number: 1158
     End of Run Comment:
    Run_type=Calibration,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=checking FPP HV=1850 V
     
    
    PRESCALE FACTORS:ps1=35000   ps2=16777215   ps3=250   ps4=1000   ps5=1   ps6=65535   ps7=1   ps8=100   
    
    EVENTS   : [0]: 1001496      [+]: 493031       [-]: 493818       
    TIME     : [0]: 13.921 mins  [+]: 6.884 mins  [-]: 6.885 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.09141 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  23.27%      [+]:  23.49%      [-]:  23.44%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :10.0/350938.0 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 9.6/2390.7 Hz   T4[0] : 9.1/9135.9 Hz   T5[0] :1527.7/1527.7 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 2.3/2.3  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :10.0/350077.2 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 9.6/2389.6 Hz   T4[+] : 9.1/9128.7 Hz   T5[+] :1525.1/1525.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 2.4/2.4  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :10.0/350930.9 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 9.6/2393.4 Hz   T4[-] : 9.1/9149.4 Hz   T5[-] :1526.4/1526.4 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 2.2/2.2  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8375/293129525  T2[0] :      0/0        T3[0] :   7987/1996906  T4[0] :   7630/7630964  T5[0] :1276063/1276063  T6[0] :      0/0        T7[0] :   1960/1960     T8[0] :   8553/855321   
    T1[+] :   4131/144593489  T2[+] :      0/0        T3[+] :   3947/986984   T4[+] :   3770/3770474  T5[+] : 629929/629929   T6[+] :      0/0        T7[+] :   1002/1002     T8[+] :   4229/422946   
    T1[-] :   4142/144974563  T2[-] :      0/0        T3[-] :   3955/988766   T4[-] :   3779/3779766  T5[-] : 630563/630563   T6[-] :      0/0        T7[-] :    909/909      T8[-] :   4230/423029   
    
    AVERAGE CURRENT
    BCM x1 : 3.5318 uA  BCM x3 : 3.5308 uA  BCM x10: 3.5606 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1287 ppm     BCM u3 :    -1192 ppm     BCM u10:    -1174 ppm     
    BCM d1 :    -1310 ppm     BCM d3 :    -1179 ppm     BCM d10:    -1170 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.002952       BCM u3 [0]:0.002949       BCM u10[0]:0.002971       
    BCM u1 [+]:0.001458       BCM u3 [+]:0.001457       BCM u10[+]:0.001468       
    BCM u1 [-]:0.001462       BCM u3 [-]:0.001461       BCM u10[-]:0.001471       
    
    BCM d1 [0]:0.002948       BCM d3 [0]:0.002949       BCM d10[0]:0.002978       
    BCM d1 [+]:0.001456       BCM d3 [+]:0.001457       BCM d10[+]:0.001471       
    BCM d1 [-]:0.00146        BCM d3 [-]:0.001461       BCM d10[-]:0.001475       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1158 at Fri May 16 06:00:04 EDT 2008
    
    Wien angle : -33.7301
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.628597
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00439975
    Right Arm arm angle : 104.999
    HALLA:p : 1192.26
    HALLA:dpp : -0.000253449
    Tiefenbach Hall A energy : 1192.26
    Left Arm Top VDC Current : 0.244141
    Left Arm Bottom VDC Current : -1.5625
    -----
    Left Arm Q1 momentum : 0.6286
    Left Arm Q1 power supply : 472.915
    Left Arm Q1 gauss meter : 0.04056
    Left Arm Q2 gauss meter : -0.10723
    Left Arm Q2 power supply current : 270.697
    Left Arm Q2 momentum : 0.628651
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 208.637
    Left Arm D1 momentum : 0.628596
    Left Arm D1 NMR : 0.264705
    Left Arm Q3 gauss meter : -0.1269
    Left Arm Q3 power supply current : 250.317
    Left Arm Q3 momentum : 0.62875
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00413044
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.79e-05
    Right Arm Q2 power supply current : -0.000177475
    Right Arm Q2 momentum : -4.1238e-07
    Right Arm Q2 gauss meter : -0.0002782
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0277112
    Right Arm D1 momentum : 0.00439539
    Right Arm D1 NMR : 0.301248
    Right Arm Q3 power supply current : -1.12089e-05
    Right Arm Q3 momentum : -2.81696e-08
    Right Arm Q3 gauss meter : -0.0002548
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.5473
    -----
    Average current of the two cavities : 3.86201
    Current on Unser monitor : 17.8868
    Current on Upstream bcm : 3.78381
    Current on Downstream bcm : 3.94022
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 97.4309
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4616
    MBSY1c Bdl : 297839
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.26
    Hall A momentum orbit correction (dpp) : -0.00025288
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.26
    Hall C energy (hallc_MeV) : 5710.5
    Delta(E)/E width (MV_AI_DXWID) : 1.51126
    IPM1C12.XPOS : 0.916804
    IPM1H04A.XPOS : 1.15483
    IPM1H04A.YPOS : 0.863626
    IPM1H04B.XPOS : 0.904259
    IPM1H04B.YPOS : 1.29697
    -----
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.3398
    HacL_HPE1313A:0_Ch54 : -0.354492
    -----
    Right Arm Collimator : -0.00820313
    HacR_HPE1313A:0_Ch58 : -0.574707
    HacR_HPE1313A:0_Ch55 : 21.9238
    HacR_HPE1313A:0_Ch54 : -0.842773
    -----
    Wien angle : -33.7301
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -782.27
    Wien field : 22.411
    Laser attenuation Hall A : 88
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.32547
    SLI vert. size mm : 0
    SLI y position : 2.35117
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 105.81
    temperature loop 1(2) : 105.32
    temperature loop 1(3) : 110.34
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 100
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0540192
    HPH H2 loop 3 : 79.4736
    -----