User name a-onl
Log entry time 06:08:15 on May 16, 2008
Entry number 238210
keyword=End_of_Run_1159
****************************
Run Number: 1159
End of Run Comment:
Run_type=Calibration,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=checking FPP HV=1825 V
PRESCALE FACTORS:ps1=35000 ps2=16777215 ps3=250 ps4=1000 ps5=1 ps6=65535 ps7=1 ps8=100
EVENTS : [0]: 73409 [+]: 36067 [-]: 36268
TIME : [0]: 1.073 mins [+]: 0.563 mins [-]: 0.562 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.18427 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 20.63% [+]: 25.45% [-]: 25.49%
TRIGGER RATES: PRES/REAL
T1[0] : 2.5/88728.0 Hz T2[0] : 0.0/0.0 Hz T3[0] :10.2/2552.5 Hz T4[0] : 9.7/9703.7 Hz T5[0] :1407.8/1407.8 Hz T6[0] : 0.0/0.0 Hz T7[0] : 2.0/2.0 Hz T8[0] :10.2/1024.0 Hz
T1[+] : 2.5/88771.6 Hz T2[+] : 0.0/0.0 Hz T3[+] :10.2/2544.4 Hz T4[+] : 9.7/9698.2 Hz T5[+] :1404.5/1404.5 Hz T6[+] : 0.0/0.0 Hz T7[+] : 1.7/1.7 Hz T8[+] :10.2/1024.0 Hz
T1[-] : 2.5/89064.0 Hz T2[-] : 0.0/0.0 Hz T3[-] :10.3/2568.4 Hz T4[-] : 9.7/9720.6 Hz T5[-] :1414.0/1414.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 2.1/2.1 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 163/5712470 T2[0] : 0/0 T3[0] : 657/164334 T4[0] : 624/624739 T5[0] : 90635/90635 T6[0] : 0/0 T7[0] : 129/129 T8[0] : 659/65927
T1[+] : 85/2996735 T2[+] : 0/0 T3[+] : 343/85894 T4[+] : 327/327389 T5[+] : 47414/47414 T6[+] : 0/0 T7[+] : 59/59 T8[+] : 345/34568
T1[-] : 85/3003998 T2[-] : 0/0 T3[-] : 346/86627 T4[-] : 327/327861 T5[-] : 47693/47693 T6[-] : 0/0 T7[-] : 71/71 T8[-] : 345/34538
AVERAGE CURRENT
BCM x1 : 3.7830 uA BCM x3 : 3.7823 uA BCM x10: 3.8144 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1408 ppm BCM u3 : -1318 ppm BCM u10: -1293 ppm
BCM d1 : -1383 ppm BCM d3 : -1307 ppm BCM d10: -1289 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.0002437 BCM u3 [0]:0.0002435 BCM u10[0]:0.0002453
BCM u1 [+]:0.0001276 BCM u3 [+]:0.0001275 BCM u10[+]:0.0001285
BCM u1 [-]:0.0001279 BCM u3 [-]:0.0001277 BCM u10[-]:0.0001287
BCM d1 [0]:0.0002434 BCM d3 [0]:0.0002435 BCM d10[0]:0.0002459
BCM d1 [+]:0.0001275 BCM d3 [+]:0.0001275 BCM d10[+]:0.0001288
BCM d1 [-]:0.0001277 BCM d3 [-]:0.0001278 BCM d10[-]:0.000129
****************************
End-of-run EPICS data for Run Number 1159 at Fri May 16 06:08:05 EDT 2008
Wien angle : -33.7301
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.628597
Left Arm arm angle : 57.5003
Right Arm D1 momentum : 0.00440983
Right Arm arm angle : 104.999
HALLA:p : 1192.57
HALLA:dpp : 0
Tiefenbach Hall A energy : 1192.57
Left Arm Top VDC Current : 0.0976562
Left Arm Bottom VDC Current : 2.14844
-----
Left Arm Q1 momentum : 0.6286
Left Arm Q1 power supply : 472.915
Left Arm Q1 gauss meter : 0.04056
Left Arm Q2 gauss meter : -0.10724
Left Arm Q2 power supply current : 270.701
Left Arm Q2 momentum : 0.62866
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 208.638
Left Arm D1 momentum : 0.628597
Left Arm D1 NMR : 0.264705
Left Arm Q3 gauss meter : -0.12691
Left Arm Q3 power supply current : 250.311
Left Arm Q3 momentum : 0.628735
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00328208
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -8.19e-05
Right Arm Q2 power supply current : -0.000144198
Right Arm Q2 momentum : -3.95198e-07
Right Arm Q2 gauss meter : -0.0002943
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0270017
Right Arm D1 momentum : 0.00440983
Right Arm D1 NMR : 0.301247
Right Arm Q3 power supply current : 0
Right Arm Q3 momentum : 0.000253554
Right Arm Q3 gauss meter : -0.0002547
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.619
BigBite Gaussmeter readback : 0.5475
-----
Average current of the two cavities : 0.0237575
Current on Unser monitor : 13.4316
Current on Upstream bcm : 0.0354259
Current on Downstream bcm : 0.0120891
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 94.3402
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4616
MBSY1c Bdl : 297839
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.57
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.57
Hall C energy (hallc_MeV) : 5710.51
Delta(E)/E width (MV_AI_DXWID) : 1.44389
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871436
HacL_HPE1313A:0_Ch58 : -0.303223
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : -0.354004
-----
Right Arm Collimator : -0.00854492
HacR_HPE1313A:0_Ch58 : -0.574707
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.843262
-----
Wien angle : -33.7301
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -782.27
Wien field : 22.411
Laser attenuation Hall A : 80
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.32547
SLI vert. size mm : 0
SLI y position : 2.35869
-----
Target : Dummy
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 1.62807e+07
Target type : 1.62807e+07
temperature loop 1(1) : 105.43
temperature loop 1(2) : 104.95
temperature loop 1(3) : 109.75
temperature loop 3(1) : 20
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 99.8
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.0540192
HPH H2 loop 3 : 79.019
-----