Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 09:19:05 on May 16, 2008

    Entry number 238227

    keyword=End_of_Run_1163
    ****************************
     Run Number: 1163
     End of Run Comment:
    Run_type=Calibration,target_type=Holely Carbon,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=checking beam position
     
    
    PRESCALE FACTORS:ps1=35000   ps2=16777215   ps3=1   ps4=1000   ps5=1000   ps6=65535   ps7=1   ps8=100   
    
    EVENTS   : [0]: 146173       [+]: 72045        [-]: 72032        
    TIME     : [0]: 2.486 mins  [+]: 1.257 mins  [-]: 1.257 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.07432 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  28.35%      [+]:  28.36%      [-]:  28.66%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 5.9/205144.0 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :1198.4/1198.4 Hz   T4[0] : 6.1/6128.2 Hz   T5[0] : 0.1/86.5 Hz   T6[0] : 0.0/0.0  Hz   T7[0] :148.4/148.4 Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] : 5.7/199568.7 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :1168.4/1168.4 Hz   T4[+] : 6.0/6016.1 Hz   T5[+] : 0.1/85.6 Hz   T6[+] : 0.0/0.0  Hz   T7[+] :144.8/144.8 Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] : 5.7/200194.5 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :1172.4/1172.4 Hz   T4[-] : 6.0/5998.3 Hz   T5[-] : 0.1/83.7 Hz   T6[-] : 0.0/0.0  Hz   T7[-] :145.4/145.4 Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    874/30599907  T2[0] :      0/0        T3[0] : 178764/178764   T4[0] :    914/914105   T5[0] :     12/12897    T6[0] :      0/0        T7[0] :  22140/22140    T8[0] :   1527/152743   
    T1[+] :    429/15046000  T2[+] :      0/0        T3[+] :  88089/88089    T4[+] :    453/453566   T5[+] :      6/6452     T6[+] :      0/0        T7[+] :  10914/10914    T8[+] :    772/77202    
    T1[-] :    431/15101001  T2[-] :      0/0        T3[-] :  88437/88437    T4[-] :    452/452464   T5[-] :      6/6317     T6[-] :      0/0        T7[-] :  10970/10970    T8[-] :    772/77242    
    
    AVERAGE CURRENT
    BCM x1 : 4.5246 uA  BCM x3 : 4.5238 uA  BCM x10: 4.5625 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1399 ppm     BCM u3 :    -1263 ppm     BCM u10:    -1254 ppm     
    BCM d1 :    -1363 ppm     BCM d3 :    -1249 ppm     BCM d10:    -1245 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0006754      BCM u3 [0]:0.0006749      BCM u10[0]:0.0006799      
    BCM u1 [+]:0.0003322      BCM u3 [+]:0.000332       BCM u10[+]:0.0003344      
    BCM u1 [-]:0.0003333      BCM u3 [-]:0.000333       BCM u10[-]:0.0003354      
    
    BCM d1 [0]:0.0006744      BCM d3 [0]:0.0006747      BCM d10[0]:0.0006812      
    BCM d1 [+]:0.0003317      BCM d3 [+]:0.0003318      BCM d10[+]:0.0003351      
    BCM d1 [-]:0.0003328      BCM d3 [-]:0.0003328      BCM d10[-]:0.0003361      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1163 at Fri May 16 09:18:56 EDT 2008
    
    Wien angle : -33.7301
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.628596
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00444499
    Right Arm arm angle : 104.999
    HALLA:p : 1192.57
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.57
    Left Arm Top VDC Current : 5.17578
    Left Arm Bottom VDC Current : 4.44336
    -----
    Left Arm Q1 momentum : 0.6286
    Left Arm Q1 power supply : 472.862
    Left Arm Q1 gauss meter : 0.04057
    Left Arm Q2 gauss meter : -0.1072
    Left Arm Q2 power supply current : 270.699
    Left Arm Q2 momentum : 0.628657
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 208.637
    Left Arm D1 momentum : 0.628596
    Left Arm D1 NMR : 0.264705
    Left Arm Q3 gauss meter : -0.12689
    Left Arm Q3 power supply current : 250.277
    Left Arm Q3 momentum : 0.62865
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00257158
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -7.77e-05
    Right Arm Q2 power supply current : -0.000118317
    Right Arm Q2 momentum : -4.89701e-07
    Right Arm Q2 gauss meter : -0.000294
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0270617
    Right Arm D1 momentum : 0.00444499
    Right Arm D1 NMR : 0.301241
    Right Arm Q3 power supply current : 7.09898e-05
    Right Arm Q3 momentum : -1.97187e-07
    Right Arm Q3 gauss meter : -0.0002578
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.5483
    -----
    Average current of the two cavities : 0.0238632
    Current on Unser monitor : 12.1123
    Current on Upstream bcm : 0.035842
    Current on Downstream bcm : 0.0118845
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.00876828
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4616
    MBSY1c Bdl : 297839
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.14
    Hall A momentum orbit correction (dpp) : 0.000478259
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.14
    Hall C energy (hallc_MeV) : 5710.44
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.348026
    IPM1H04A.XPOS : 1.60388
    IPM1H04A.YPOS : 0.790648
    IPM1H04B.XPOS : 0.88332
    IPM1H04B.YPOS : 1.22659
    -----
    Left Arm Collimator : 0.871484
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : -0.353027
    -----
    Right Arm Collimator : -0.00830078
    HacR_HPE1313A:0_Ch58 : -0.574219
    HacR_HPE1313A:0_Ch55 : 21.9238
    HacR_HPE1313A:0_Ch54 : -0.84375
    -----
    Wien angle : -33.7301
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -782.27
    Wien field : 22.411
    Laser attenuation Hall A : 82
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.35528
    SLI vert. size mm : 0
    SLI y position : 2.33615
    -----
    Target : Carbon w/ Hole
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 1.07288e+07
    Target type : 1.07288e+07
    temperature loop 1(1) : 99.92
    temperature loop 1(2) : 99.48
    temperature loop 1(3) : 100.36
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 94.3
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 93.7188
    -----