Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 09:37:20 on May 16, 2008

    Entry number 238229

    keyword=End_of_Run_1164
    ****************************
     Run Number: 1164
     End of Run Comment:
    Run_type=Calibration,target_type=Holely Carbon,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=checking beam position
     
    
    PRESCALE FACTORS:ps1=35000   ps2=16777215   ps3=1   ps4=1000   ps5=1000   ps6=65535   ps7=1   ps8=100   
    
    EVENTS   : [0]: 78782        [+]: 39192        [-]: 38567        
    TIME     : [0]: 2.229 mins  [+]: 1.130 mins  [-]: 1.131 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.06411 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  20.78%      [+]:  23.25%      [-]:  23.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 3.4/119945.9 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :644.9/644.9 Hz   T4[0] : 4.9/4948.6 Hz   T5[0] : 0.0/48.9 Hz   T6[0] : 0.0/0.0  Hz   T7[0] :80.7/80.7 Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] : 3.4/120026.4 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :651.9/651.9 Hz   T4[+] : 5.0/4959.3 Hz   T5[+] : 0.0/48.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] :83.2/83.2 Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] : 3.4/120299.6 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :642.3/642.3 Hz   T4[-] : 4.9/4941.8 Hz   T5[-] : 0.0/50.0 Hz   T6[-] : 0.0/0.0  Hz   T7[-] :78.0/78.0 Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    458/16044644  T2[0] :      0/0        T3[0] :  86266/86266    T4[0] :    661/661955   T5[0] :      6/6535     T6[0] :      0/0        T7[0] :  10789/10789    T8[0] :   1369/136976   
    T1[+] :    232/8139528  T2[+] :      0/0        T3[+] :  44210/44210    T4[+] :    336/336315   T5[+] :      3/3261     T6[+] :      0/0        T7[+] :   5643/5643     T8[+] :    694/69442    
    T1[-] :    233/8161695  T2[-] :      0/0        T3[-] :  43578/43578    T4[-] :    335/335274   T5[-] :      3/3391     T6[-] :      0/0        T7[-] :   5294/5294     T8[-] :    694/69473    
    
    AVERAGE CURRENT
    BCM x1 : 4.7648 uA  BCM x3 : 4.7642 uA  BCM x10: 4.8049 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1233 ppm     BCM u3 :    -1180 ppm     BCM u10:    -1167 ppm     
    BCM d1 :    -1268 ppm     BCM d3 :    -1157 ppm     BCM d10:    -1166 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0006376      BCM u3 [0]:0.0006372      BCM u10[0]:0.0006419      
    BCM u1 [+]:0.0003229      BCM u3 [+]:0.0003228      BCM u10[+]:0.0003251      
    BCM u1 [-]:0.0003239      BCM u3 [-]:0.0003237      BCM u10[-]:0.0003261      
    
    BCM d1 [0]:0.0006371      BCM d3 [0]:0.0006374      BCM d10[0]:0.0006436      
    BCM d1 [+]:0.0003227      BCM d3 [+]:0.0003229      BCM d10[+]:0.000326       
    BCM d1 [-]:0.0003237      BCM d3 [-]:0.0003238      BCM d10[-]:0.0003269      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1164 at Fri May 16 09:37:11 EDT 2008
    
    Wien angle : -33.7301
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.628596
    Left Arm arm angle : 57.5003
    Right Arm D1 momentum : 0.00437985
    Right Arm arm angle : 104.999
    HALLA:p : 1192.3
    HALLA:dpp : -0.000222837
    Tiefenbach Hall A energy : 1192.3
    Left Arm Top VDC Current : 4.3457
    Left Arm Bottom VDC Current : -1.02539
    -----
    Left Arm Q1 momentum : 0.6286
    Left Arm Q1 power supply : 472.915
    Left Arm Q1 gauss meter : 0.04055
    Left Arm Q2 gauss meter : -0.10718
    Left Arm Q2 power supply current : 270.698
    Left Arm Q2 momentum : 0.628655
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 208.639
    Left Arm D1 momentum : 0.628596
    Left Arm D1 NMR : 0.264705
    Left Arm Q3 gauss meter : -0.12689
    Left Arm Q3 power supply current : 250.276
    Left Arm Q3 momentum : 0.628647
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00369035
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -8.96e-05
    Right Arm Q2 power supply current : -0.000162685
    Right Arm Q2 momentum : -3.78015e-07
    Right Arm Q2 gauss meter : -0.0002879
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0267864
    Right Arm D1 momentum : 0.00437876
    Right Arm D1 NMR : 0.301253
    Right Arm Q3 power supply current : -0.000134507
    Right Arm Q3 momentum : -3.38035e-07
    Right Arm Q3 gauss meter : -0.0002581
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.5483
    -----
    Average current of the two cavities : 4.87602
    Current on Unser monitor : 17.7816
    Current on Upstream bcm : 4.80557
    Current on Downstream bcm : 4.94646
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 98.0047
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4616
    MBSY1c Bdl : 297839
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.28
    Hall A momentum orbit correction (dpp) : -0.000242299
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.28
    Hall C energy (hallc_MeV) : 5710.52
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.938877
    IPM1H04A.XPOS : -0.84252
    IPM1H04A.YPOS : 0.724808
    IPM1H04B.XPOS : -1.29187
    IPM1H04B.YPOS : 1.64665
    -----
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.302734
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.353516
    -----
    Right Arm Collimator : -0.00825195
    HacR_HPE1313A:0_Ch58 : -0.574219
    HacR_HPE1313A:0_Ch55 : 21.9238
    HacR_HPE1313A:0_Ch54 : -0.842773
    -----
    Wien angle : -33.7301
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -782.27
    Wien field : 22.411
    Laser attenuation Hall A : 94
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.32547
    SLI vert. size mm : 0
    SLI y position : 2.35117
    -----
    Target : Carbon w/ Hole
    fan frequency loop 1 : 0
    fan frequency loop 3 : 35.5
    Encoder position : 1.07288e+07
    Target type : 1.07288e+07
    temperature loop 1(1) : 99.51
    temperature loop 1(2) : 99.06
    temperature loop 1(3) : 99.74
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 93.9
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 96.2071
    -----