NEXT
User name a-onl
Log entry time 10:02:49 on May 16, 2008
Entry number 238234
keyword=Start_Run_1167,Run_type=Calibration,target_type=Holely Carbon,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=checking beam position
Run Timestamp: Fri May 16 10:02:20 EDT 2008
Beginning-of-run EPICS data for Run Number 1167 at Fri May 16 10:02:26 EDT 2008
Run_type=Calibration
target_type=Holely Carbon
beam_e0=1.192
beam_raster=on
leftarm_p=0.6286
leftarm_theta=57.5
leftarm_colli=out
bbarm_i=700
bbarm_theta=30.25
bbarm_zoff=
comment_text=checking beam position
; BBite+HRS DAQ on adaql2/a-onl account
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = BigBite Calorimeter
; T2 = undefined
; T3 = L-HRS Singles (S1.and.S2)
; T4 = L-HRS Efficiency (S1.or.S2)
; T5 = T1.AND.T3 (BigBite LHRS Coincidence)
; T6 = undefined
; T7 = BigBite Cosmics
; T8 = 1024 Hz pulser
; String should be one line, no spaces, ending in carriage return
ps1=35000,ps2=16777215,ps3=1,ps4=1000,ps5=1000,ps6=65535,ps7=1,ps8=100
Left Arm Q1 momentum : 0.6286
Left Arm Q1 power supply : 472.862
Left Arm Q1 gauss meter : 0.04055
Left Arm Q2 power supply current : 270.701
Left Arm Q2 momentum : 0.62866
Left Arm Q2 gauss meter : -0.10719
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 208.637
Left Arm D1 momentum : 0.628596
Left Arm D1 NMR : 0.264705
Left Arm Q3 power supply current : 250.279
Left Arm Q3 momentum : 0.628654
Left Arm Q3 gauss meter : -0.12689
Left Arm Q3 power supply polarity : enabled
Left Arm B Field Hall Probe (D-G) : 0.2251
-----
Right Arm Q1 momentum : 0.00355779
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -8.71e-05
Right Arm Q2 power supply current : -3.69739e-05
Right Arm Q2 momentum : -8.59125e-08
Right Arm Q2 gauss meter : -0.0002852
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0268322
Right Arm D1 momentum : 0.00438503
Right Arm D1 NMR : 0.301252
Right Arm Q3 power supply current : 3.7363e-06
Right Arm Q3 momentum : 0.000237322
Right Arm Q3 gauss meter : -0.0002576
Right Arm Q3 power supply polarity : enabled
Right Arm B Field Hall Probe (D-G) : -0.0016149
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.619
BigBite Gaussmeter readback : 0.5487
-----
Left Arm Top VDC Current : 0.488281
Left Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 3.9834
Left Arm Bottom VDC voltage : 3.99023
-----
Right Arm Top VDC Current : -1.17188
Right Arm Bottom VDC Current : -1.12305
Right Arm Top VDC voltage : -0.0112305
Right Arm Bottom VDC voltage : 0.000488281
-----
Average current of the two cavities : 4.67474
Current on Unser monitor : 17.1647
Current on Upstream bcm : 4.61259
Current on Downstream bcm : 4.7369
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 99.4138
Hall C Current : ibcm1 --- Invalid channel name
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.29
Hall A momentum orbit correction (dpp) : -0.000228294
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.29
Hall C energy (hallc_MeV) : 5710.52
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c magnet current (amp) : 49.4616
MBSY1c Bdl : 297839
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 3
Raster Y width : 4
-----
Left Arm Collimator : 0.871436
HacL_HPE1313A:0_Ch58 : -0.302734
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.353027
Left Arm Angle Floor Angle : 57.5
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 57.5003
-----
Right Arm Arm Collimator : -0.00864258
HacR_HPE1313A:0_Ch58 : -0.57373
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.84375
Right Arm Angle Floor Angle : 105
Right Arm Angle Vernier : -34.4
Right Arm Scattering Angle : 104.999
-----
IPM1C12.XPOS : 0.927016
IPM1C12.YPOS : 0.53192
IPM1H04A.XPOS : -0.658
IPM1H04A.YPOS : 0.7184
IPM1H04B.XPOS : -1.08339
IPM1H04B.YPOS : 1.63802
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----
Wien angle : -33.7301
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 22.411
Laser attenuation Hall A : 93
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
Target : Carbon w/ Hole
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 36
Encoder position : 1.07288e+07
Target type : 1.07288e+07
temperature loop 1(1) : 98.96
temperature loop 1(2) : 98.52
temperature loop 1(3) : 99.29
Heat exchange loop 1 H2 : 93.4
temperature loop 3(1) : 20
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange loop 3 H2 : 20
pressure loop He : 40.7692
pressure loop H2 before : 30.4311
pressure loop H2 return : 30.6996
HPH He loop 1 : 0.0540192
HPH H2 loop 3 : 47.9288
----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.34037
SLI vert. size mm : 0
SLI y position : 2.3662
-----
FPP High Voltages and Currents at Fri May 16 10:02:36 EDT 2008
MF7b1469_7gn0gen.F 1825.2
MF7b1469_7gn0gen.E 0.8
MF7b1469_7gn0ch0property.F 1825.2
MF7b1469_7gn0ch0property.E 0.02
MF7b1469_7gn0ch1property.F 1825.2
MF7b1469_7gn0ch1property.E 0.07
MF7b1469_7gn0ch2property.F 1825.2
MF7b1469_7gn0ch2property.E 0.01
MF7b1469_7gn0ch3property.F 1825.2
MF7b1469_7gn0ch3property.E 0.04
MF7b1469_7gn0ch4property.F 1825.2
MF7b1469_7gn0ch4property.E 0.04
MF7b1469_7gn1gen.F 1825.4
MF7b1469_7gn1gen.E 0.3
MF7b1469_7gn1ch0property.F 1825.4
MF7b1469_7gn1ch0property.E 0.03
MF7b1469_7gn1ch1property.F 1825.4
MF7b1469_7gn1ch1property.E 0.04
MF7b1469_7gn1ch2property.F 1825.4
MF7b1469_7gn1ch2property.E 0
MF7b1469_7gn1ch3property.F 1825.4
MF7b1469_7gn1ch3property.E 0.01
MF7b1469_7gn1ch4property.F 1825.4
MF7b1469_7gn1ch4property.E 0.05
MF7b1469_8gn0gen.F 1825.9
MF7b1469_8gn0gen.E 1
MF7b1469_8gn0ch0property.F 1825.9
MF7b1469_8gn0ch0property.E -0.02
MF7b1469_8gn0ch1property.F 1825.9
MF7b1469_8gn0ch1property.E 0.02
MF7b1469_8gn0ch2property.F 1825.9
MF7b1469_8gn0ch2property.E 0.02
MF7b1469_8gn0ch3property.F 1825.9
MF7b1469_8gn0ch3property.E 0.01
MF7b1469_8gn0ch4property.F 1825.9
MF7b1469_8gn0ch4property.E -0.01
MF7b1469_8gn1gen.F 1824.4
MF7b1469_8gn1gen.E 1
MF7b1469_8gn1ch0property.F 1824.4
MF7b1469_8gn1ch0property.E -0
MF7b1469_8gn1ch1property.F 1824.4
MF7b1469_8gn1ch1property.E 0.04
MF7b1469_8gn1ch2property.F 1824.4
MF7b1469_8gn1ch2property.E 0
MF7b1469_8gn1ch3property.F 1824.4
MF7b1469_8gn1ch3property.E -0
MF7b1469_8gn1ch4property.F 1824.4
MF7b1469_8gn1ch4property.E 0.06
MF7b1469_8gn2gen.F 23.4
MF7b1469_8gn2gen.E 0.7
MF7b1469_8gn2ch0property.F 0
MF7b1469_8gn2ch0property.E 0
FPP Chamber Threshold voltages at Fri May 16 10:02:37 EDT 2008
HrsH_FPP_TH1 3.90918
HrsH_FPP_TH2 4.02783
HrsH_FPP_TH3 6.96191
HrsH_FPP_TH4 7.06885
FPP Wire Chambers Low Voltage at Fri May 16 10:02:38 EDT 2008
HrsH_FPP_LV11P 4.91748
HrsH_FPP_LV11M -5.3418
HrsH_FPP_LV12MA -5.24902
HrsH_FPP_LV12MB -5.58447
HrsH_FPP_LV21P 5.08105
HrsH_FPP_LV21M -4.54492
HrsH_FPP_LV22MA -4.70996
HrsH_FPP_LV22MB -4.72998
HrsH_FPP_LV31P 4.78369
HrsH_FPP_LV31M -5.10205
HrsH_FPP_LV32MA -2.7959
HrsH_FPP_LV32MB -1.51416
HrsH_FPP_LV42P 4.75732
HrsH_FPP_LV42MA -4.7168
HrsH_FPP_LV42MB -4.57471
HrsH_FPP_LV41P 4.70996
HrsH_FPP_LV41MA -4.77148
HrsH_FPP_LV41MB -4.59521
FPP Level Shifters at Fri May 16 10:02:38 EDT 2008
HacH_DTC_HPE1313A:0_Ch48 5.07178
HacH_DTC_HPE1313A:0_Ch50 -5.11279
FPP Gas Flow at Fri May 16 10:02:38 EDT 2008
HrsH_GAS_rFPPc1 5.20963
HrsH_GAS_rFPPc2 3.21788
HrsH_GAS_rFPPc3 5.18717
HrsH_GAS_rFPPc4 5.89196
FPP Carbon Door Status at Fri May 16 10:02:39 EDT 2008
HacH_DTC_VMIC1182:0_Ch13 enabled
HacH_DTC_VMIC1182:0_Ch17 enabled
HacH_DTC_VMIC1182:0_Ch9 enabled
HacH_DTC_VMIC1182:0_Ch5 enabled
Left S2 HV
S2 Slot0 ch0 : -2310.3
S2 Slot0 ch1 : -2212.3
S2 Slot0 ch2 : -2165.7
S2 Slot0 ch3 : -2231.2
S2 Slot0 ch4 : -1793.8
S2 Slot0 ch5 : -2166.5
S2 Slot0 ch6 : -1940.7
S2 Slot0 ch7 : -1876.9
S2 Slot0 ch8 : -2030.4
S2 Slot0 ch9 : -1888.8
S2 Slot0 ch10 : -2094.7
S2 Slot0 ch11 : -1867.9
-----
Left S1 HV
S1 Slot1 ch0 : -1785.2
S1 Slot1 ch1 : -1809.8
S1 Slot1 ch2 : -1790.2
S1 Slot1 ch3 : -1817.7
S1 Slot1 ch4 : -1699.9
S1 Slot1 ch5 : -1855.4
S1 Slot1 ch6 : -1915.4
S1 Slot1 ch7 : -1700.9
S1 Slot1 ch8 : -1961.1
S1 Slot1 ch9 : -1746.3
S1 Slot1 ch10 : -1798.4
S1 Slot1 ch11 : -1707.6
-----
Left Cerenkov HV
GCER Slot2 ch0 : -1543.5
GCER Slot2 ch1 : -1462.1
GCER Slot2 ch2 : -1528.8
GCER Slot2 ch3 : -1453
GCER Slot2 ch4 : -1797.3
GCER Slot2 ch5 : -1983.6
GCER Slot2 ch6 : -1750.5
GCER Slot2 ch7 : -1751.9
GCER Slot2 ch8 : -2009.9
GCER Slot2 ch9 : -1588.6
GCER Slot2 ch10 : -15
GCER Slot2 ch11 : -23.6
-----
Left Pion Rejector Layer 1 HV
PRL1 Slot3 ch0 : -860.4
PRL1 Slot3 ch1 : -784.5
PRL1 Slot3 ch2 : -905.8
PRL1 Slot3 ch3 : -980.5
PRL1 Slot3 ch4 : -731.1
PRL1 Slot3 ch5 : -811
PRL1 Slot3 ch6 : -1081.3
PRL1 Slot3 ch7 : -990.8
PRL1 Slot3 ch8 : -810.5
PRL1 Slot3 ch9 : -790.9
PRL1 Slot3 ch10 : -829.5
PRL1 Slot3 ch11 : -785.3
PRL1 Slot4 ch0 : -870.1
PRL1 Slot4 ch1 : -900.5
PRL1 Slot4 ch2 : -750
PRL1 Slot4 ch3 : -895.9
PRL1 Slot4 ch4 : -921.7
PRL1 Slot4 ch5 : -821.2
PRL1 Slot4 ch6 : -836
PRL1 Slot4 ch7 : -826.4
PRL1 Slot4 ch8 : -1190.3
PRL1 Slot4 ch9 : -991.4
PRL1 Slot4 ch10 : -1031.7
PRL1 Slot4 ch11 : -861.4
PRL1 Slot5 ch0 : -1041.1
PRL1 Slot5 ch1 : -871
PRL1 Slot5 ch2 : -916.2
PRL1 Slot5 ch3 : -735.8
PRL1 Slot5 ch4 : -890.7
PRL1 Slot5 ch5 : -810.3
PRL1 Slot5 ch6 : -821.1
PRL1 Slot5 ch7 : -895.6
PRL1 Slot5 ch8 : -741.3
PRL1 Slot5 ch9 : -841.4
PRL1 Slot5 ch10 : -16.5
PRL1 Slot5 ch11 : -25.6
-----
Left Pion Rejector Layer 2 HV
PRL2 Slot9 ch0 : -920.5
PRL2 Slot9 ch1 : -881.3
PRL2 Slot9 ch2 : -800.1
PRL2 Slot9 ch3 : -869.9
PRL2 Slot9 ch4 : -810.9
PRL2 Slot9 ch5 : -941.5
PRL2 Slot9 ch6 : -851.5
PRL2 Slot9 ch7 : -890.6
PRL2 Slot9 ch8 : -811.4
PRL2 Slot9 ch9 : -780.6
PRL2 Slot9 ch10 : -821
PRL2 Slot9 ch11 : -851.4
PRL2 Slot10 ch0 : -756.5
PRL2 Slot10 ch1 : -812.4
PRL2 Slot10 ch2 : -871
PRL2 Slot10 ch3 : -900.8
PRL2 Slot10 ch4 : -881.4
PRL2 Slot10 ch5 : -871
PRL2 Slot10 ch6 : -815.2
PRL2 Slot10 ch7 : -824.8
PRL2 Slot10 ch8 : -760.3
PRL2 Slot10 ch9 : -715.7
PRL2 Slot10 ch10 : -911
PRL2 Slot10 ch11 : -781.3
PRL2 Slot11 ch0 : -1000.7
PRL2 Slot11 ch1 : -900.4
PRL2 Slot11 ch2 : -850.6
PRL2 Slot11 ch3 : -1079.9
PRL2 Slot11 ch4 : -1050.2
PRL2 Slot11 ch5 : -800
PRL2 Slot11 ch6 : -860.4
PRL2 Slot11 ch7 : -1031.3
PRL2 Slot11 ch8 : -911.3
PRL2 Slot11 ch9 : -880.3
PRL2 Slot11 ch10 : -12.9
PRL2 Slot11 ch11 : -24.7
-----
# Map BB_DE Measured Voltage
1 : -1316 -1496
2 : -1420 -1333
3 : -1301 -1467
4 : -1631 -1618
5 : -1362 -1427
6 : -1444 -1444
7 : -1284 -1168
8 : -1345 -1456
9 : -1174 -1566
10 : -1566 -1279
11 : -1480 -1218
12 : -1281 -1564
13 : -1582 -1549
14 : -1167 -1475
15 : -1380 -1574
16 : -1403 -1323
17 : -1161 -1513
18 : -1431 -1278
19 : -1514 -1564
20 : -1369 -1546
21 : -1559 -1413
22 : -1494 -1618
23 : -1768 -1414
24 : -1558 -1284
# Map BB_DE Measured Current
1 : -139 -169
2 : -152 -148
3 : -138 -165
4 : -172 -185
5 : -145 -150
6 : -157 -158
7 : -140 -127
8 : -143 -162
9 : -126 -172
10 : -161 -138
11 : -160 -127
12 : -140 -176
13 : -172 -158
14 : -126 -163
15 : -152 -173
16 : -149 -142
17 : -126 -155
18 : -159 -136
19 : -170 -165
20 : -153 -172
21 : -168 -150
22 : -167 -150
23 : -196 -150
24 : -167 -137
# Map BB_E Measured Voltage
1 : -1456 -1479
2 : -1648 -1283
3 : -1298 -1334
4 : -1207 -1193
5 : -1330 -1555
6 : -1410 -1566
7 : -1550 -1284
8 : -1184 -1484
9 : -1287 -1514
10 : -1250 -1222
11 : -1572 -1472
12 : -1229 -1545
13 : -1632 -1360
14 : -1240 -1420
15 : -1565 -1254
16 : -1244 -1555
17 : -1488 -1389
18 : -1520 -1206
19 : -1345 -1540
20 : -1493 -1459
21 : -1470 -1454
22 : -1480 -1155
23 : -1391 -1227
24 : -1142 -3
# Map BB_E Measured Current
1 : -152 -156
2 : -177 -136
3 : -139 -146
4 : -132 -130
5 : -145 -166
6 : -150 -173
7 : -165 -134
8 : -126 -164
9 : -136 -156
10 : -132 -129
11 : -166 -155
12 : -133 -165
13 : -175 -140
14 : -131 -144
15 : -168 -131
16 : -135 -147
17 : -164 -147
18 : -167 -127
19 : -141 -163
20 : -158 -161
21 : -156 -149
22 : -158 -116
23 : -148 -129
24 : -126 -3
# Map BB_SC_R Measured Voltage
1 : -1176
2 : -1154
3 : -1174
4 : -1159
5 : -1190
6 : -1201
7 : -1267
8 : -1126
9 : -1196
10 : -1274
11 : -1306
12 : -1176
13 : -1293
# Map BB_SC_R Measured Current
1 : -444
2 : -437
3 : -444
4 : -439
5 : -453
6 : -454
7 : -477
8 : -426
9 : -455
10 : -483
11 : -492
12 : -445
13 : -489
# Map BB_DC Measured Voltage
1 : -23 -25 -21 -20
2 : -21 -25 -25 -25
3 : -1600 -1600 -1600 -1600
# Map BB_DC Measured Current
1 : -0 -0 0 -0
2 : -0 -0 -0 -0
3 : -4 -4 -30 -32
# Map BB_PS_R Measured Voltage
1 : -883
2 : -842
3 : -845
4 : -853
5 : -858
6 : -848
7 : -829
8 : -844
9 : -895
10 : -897
11 : -842
12 : -856
13 : -860
14 : -849
15 : -817
16 : -916
17 : -787
18 : -807
19 : -824
20 : -810
21 : -815
22 : -795
23 : -815
24 : -800
25 : -765
26 : -848
27 : -850
# Map BB_PS_R Measured Current
1 : -227
2 : -215
3 : -217
4 : -219
5 : -222
6 : -217
7 : -213
8 : -216
9 : -229
10 : -229
11 : -216
12 : -218
13 : -223
14 : -219
15 : -206
16 : -234
17 : -201
18 : -207
19 : -210
20 : -208
21 : -208
22 : -204
23 : -208
24 : -205
25 : -197
26 : -218
27 : -221
# Map BB_SC_L Measured Voltage
1 : -1234
2 : -1270
3 : -1215
4 : -1140
5 : -1162
6 : -1268
7 : -1316
8 : -1122
9 : -1200
10 : -1243
11 : -1317
12 : -1230
13 : -1242
# Map BB_SC_L Measured Current
1 : -449
2 : -422
3 : -453
4 : -409
5 : -397
6 : -458
7 : -466
8 : -405
9 : -424
10 : -476
11 : -482
12 : -473
13 : -472
# Map BB_PS_L Measured Voltage
1 : -895
2 : -885
3 : -816
4 : -888
5 : -859
6 : -867
7 : -857
8 : -804
9 : -869
10 : -894
11 : -860
12 : -865
13 : -864
14 : -858
15 : -885
16 : -861
17 : -869
18 : -914
19 : -844
20 : -865
21 : -847
22 : -845
23 : -840
24 : -862
25 : -898
26 : -854
27 : -887
# Map BB_PS_L Measured Current
1 : -231
2 : -229
3 : -206
4 : -227
5 : -222
6 : -224
7 : -219
8 : -206
9 : -223
10 : -228
11 : -223
12 : -221
13 : -219
14 : -220
15 : -230
16 : -218
17 : -223
18 : -232
19 : -218
20 : -224
21 : -216
22 : -217
23 : -216
24 : -222
25 : -231
26 : -221
27 : -223
# Map BB_SH Measured Voltage
1 : -1316 -1420 -1301 -1631 -1585 -1722 -1321
2 : -1362 -1444 -1284 -1470 -1329 -1252 -1517
3 : -1345 -1174 -1566 -1480 -1456 -1551 -1497
4 : -1281 -1582 -1167 -1586 -1360 -1649 -1528
5 : -1380 -1403 -1161 -1431 -1265 -1376 -1483
6 : -1514 -1369 -1559 -1610 -1666 -1415 -1277
7 : -1494 -1768 -1558 -1496 -1617 -1417 -1576
8 : -1333 -1467 -1618 -1103 -1585 -1682 -1426
9 : -1427 -1444 -1168 -1456 -1459 -1286 -1489
10 : -1566 -1279 -1218 -1171 -1279 -1276 -1494
11 : -1564 -1549 -1475 -1574 -1406 -1419 -1177
12 : -1323 -1513 -1278 -1449 -1387 -1531 -1520
13 : -1564 -1546 -1413 -1618 -1216 -1526 -1557
14 : -1414 -1284 -1456 -1322 -1502 -1529 -1535
15 : -1648 -1298 -1207 -1330 -1520 -1412 -1461
16 : -1410 -1550 -1184 -1592 -1386 -1538 -1212
17 : -1287 -1250 -1572 -1229 -1418 -1480 -1523
18 : -1632 -1240 -1565 -1189 -1627 -1402 -1343
19 : -1244 -1488 -1520 -1345 -1143 -1603 -1157
20 : -1493 -1470 -1480 -1279 -1341 -1366 -1463
21 : -1391 -1142 -1479 -1283 -1571 -1402 -1234
22 : -1334 -1193 -1555 -1377 -1566 -1518 -1421
23 : -1566 -1284 -1484 -1514 -1601 -1180 -1322
24 : -1222 -1472 -1545 -1465 -1281 -1471 -1346
25 : -1360 -1420 -1254 -1555 -1327 -1304 -1509
26 : -1389 -1206 -1540 -1281 -1263 -1522 -1417
27 : -1459 -1454 -1155 -1227 -1261 -1420 -1425
# Map BB_SH Measured Current
1 : -139 -152 -138 -172 -168 -184 -140
2 : -145 -157 -140 -156 -140 -132 -164
3 : -143 -126 -161 -160 -153 -167 -156
4 : -140 -172 -126 -165 -147 -168 -161
5 : -152 -149 -126 -159 -127 -143 -153
6 : -170 -153 -168 -166 -183 -145 -141
7 : -167 -196 -167 -169 -169 -145 -170
8 : -148 -165 -185 -119 -167 -185 -152
9 : -150 -158 -127 -162 -160 -142 -156
10 : -172 -138 -127 -126 -139 -137 -156
11 : -176 -158 -163 -173 -154 -149 -130
12 : -142 -155 -136 -151 -148 -164 -163
13 : -165 -172 -150 -150 -129 -164 -159
14 : -150 -137 -152 -141 -160 -167 -159
15 : -177 -139 -132 -145 -163 -157 -153
16 : -150 -165 -126 -169 -147 -165 -123
17 : -136 -132 -166 -133 -147 -156 -166
18 : -180 -129 -170 -127 -178 -153 -142
19 : -132 -168 -166 -143 -124 -169 -123
20 : -156 -153 -158 -139 -141 -144 -156
21 : -148 -121 -156 -134 -166 -149 -132
22 : -146 -130 -165 -143 -167 -165 -155
23 : -171 -137 -161 -162 -171 -129 -141
24 : -130 -155 -164 -161 -133 -154 -146
25 : -142 -146 -129 -147 -140 -139 -160
26 : -151 -125 -163 -139 -131 -165 -153
27 : -159 -150 -119 -128 -132 -151 -155
# Map BB_TESTMAP Measured Voltage
1 : -1459 -1454 -1155 -1227 -1261 -1420 -1425
2 : -1389 -1206 -1540 -1281 -1263 -1522 -1417
3 : -1360 -1420 -1254 -1555 -1327 -1304 -1509
4 : -1222 -1472 -1545 -1465 -1281 -1471 -1346
5 : -1566 -1284 -1484 -1514 -1601 -1180 -1322
6 : -1334 -1193 -1555 -1377 -1566 -1518 -1421
7 : -1391 -1142 -1479 -1283 -1571 -1402 -1234
8 : -1493 -1470 -1480 -1279 -1341 -1366 -1463
9 : -1244 -1488 -1520 -1345 -1143 -1603 -1157
10 : -1632 -1240 -1565 -1189 -1627 -1402 -1343
11 : -1287 -1250 -1572 -1229 -1418 -1480 -1523
12 : -1410 -1550 -1184 -1592 -1386 -1538 -1212
13 : -1648 -1298 -1207 -1330 -1520 -1412 -1461
14 : -1414 -1284 -1456 -1322 -1502 -1529 -1535
15 : -1564 -1546 -1413 -1618 -1216 -1526 -1557
16 : -1323 -1513 -1278 -1449 -1387 -1531 -1520
17 : -1564 -1549 -1475 -1574 -1406 -1419 -1177
18 : -1566 -1279 -1218 -1171 -1279 -1276 -1494
19 : -1427 -1444 -1168 -1456 -1459 -1286 -1489
20 : -1333 -1467 -1618 -1103 -1585 -1682 -1426
21 : -1494 -1768 -1558 -1496 -1617 -1417 -1576
22 : -1514 -1369 -1559 -1610 -1666 -1415 -1277
23 : -1380 -1403 -1161 -1431 -1265 -1376 -1483
24 : -1281 -1582 -1167 -1586 -1360 -1649 -1528
25 : -1345 -1174 -1566 -1480 -1456 -1551 -1497
26 : -1362 -1444 -1284 -1470 -1329 -1252 -1517
27 : -1316 -1420 -1301 -1631 -1585 -1722 -1321
# Map BB_TESTMAP Measured Current
1 : -159 -150 -119 -128 -132 -151 -155
2 : -151 -125 -163 -139 -131 -165 -153
3 : -142 -146 -129 -147 -140 -139 -160
4 : -130 -155 -164 -161 -133 -154 -146
5 : -171 -137 -161 -162 -171 -129 -141
6 : -146 -130 -165 -143 -167 -165 -155
7 : -148 -121 -156 -134 -166 -149 -132
8 : -156 -153 -158 -139 -141 -144 -156
9 : -132 -168 -166 -143 -124 -169 -123
10 : -180 -129 -170 -127 -178 -153 -142
11 : -136 -132 -166 -133 -147 -156 -166
12 : -150 -165 -126 -169 -147 -165 -123
13 : -177 -139 -132 -145 -163 -157 -153
14 : -150 -137 -152 -141 -160 -167 -159
15 : -165 -172 -150 -150 -129 -164 -159
16 : -142 -155 -136 -151 -148 -164 -163
17 : -176 -158 -163 -173 -154 -149 -130
18 : -172 -138 -127 -126 -139 -137 -156
19 : -150 -158 -127 -162 -160 -142 -156
20 : -148 -165 -185 -119 -167 -185 -152
21 : -167 -196 -167 -169 -169 -145 -170
22 : -170 -153 -168 -166 -183 -145 -141
23 : -152 -149 -126 -159 -127 -143 -153
24 : -140 -172 -126 -171 -142 -168 -161
25 : -143 -126 -161 -160 -153 -165 -158
26 : -145 -157 -140 -154 -137 -133 -169
27 : -139 -152 -138 -172 -171 -183 -143
BigBite thresholds E dE(tdc) dE(trigger)
Wed May 7 16:11:49 EDT 2008 375 140 280
Threshold for 'mwdc_back' is +7.504 V (3072)
USAGE: ./threshold
-g|--get|get Get threshold for
-s|--set|set Set threshold for to
-v Verbose.
-h This help text.
is a voltage in units of mV or V
is from table below
name Channel Range Description
----- ------- ------- -----------
BB_Cer 7 -1V -- 0V BB Cerenkov Threshold
BB_PSh 6 -1V -- 0V BB Preshower Threshold
BB_Sh 5 -1V -- 0V BB Shower Threshold
mwdc_back 2 0V -- +15V Back MWDC Threshold
Using controller IP: bbcamac1.jlab.org. I/O reg in slot 12
Using cnaf command: './cnafb'
Examples:
./threshold -g mwdc_back
---> Return thresh for mwdc_back
./threshold -s BB_Sh -200
---> Set thresh for BB_Sh to -200 mV
./threshold -s mwdc_back 100mV
---> Set thresh for mwdc_back to 100 mV
./threshold -s mwdc_back 1.0V
---> Set thresh for mwdc_back to 1.0 V