Log entry time 10:03:59 on May 16, 2008
Entry number 238235
keyword=End_of_Run_1167
****************************
Run Number: 1167
End of Run Comment:
Run_type=Calibration,target_type=Holely Carbon,beam_e0=1.192,beam_raster=on,leftarm_p=0.6286,leftarm_theta=57.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=30.25,bbarm_zoff=,comment_text=checking beam position
PRESCALE FACTORS:ps1=35000 ps2=16777215 ps3=1 ps4=1000 ps5=1000 ps6=65535 ps7=1 ps8=100
EVENTS : [0]: 56307 [+]: 27627 [-]: 27727
TIME : [0]: 1.246 mins [+]: 0.647 mins [-]: 0.647 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.09273 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 23.91% [+]: 27.70% [-]: 27.93%
TRIGGER RATES: PRES/REAL
T1[0] : 4.3/150989.1 Hz T2[0] : 0.0/0.0 Hz T3[0] :868.7/868.7 Hz T4[0] : 5.3/5335.9 Hz T5[0] : 0.1/62.7 Hz T6[0] : 0.0/0.0 Hz T7[0] :101.9/101.9 Hz T8[0] :10.2/1024.0 Hz
T1[+] : 4.3/150484.2 Hz T2[+] : 0.0/0.0 Hz T3[+] :864.1/864.1 Hz T4[+] : 5.3/5327.0 Hz T5[+] : 0.1/62.4 Hz T6[+] : 0.0/0.0 Hz T7[+] :101.5/101.5 Hz T8[+] :10.2/1024.0 Hz
T1[-] : 4.3/150824.0 Hz T2[-] : 0.0/0.0 Hz T3[-] :870.4/870.4 Hz T4[-] : 5.3/5327.6 Hz T5[-] : 0.1/63.2 Hz T6[-] : 0.0/0.0 Hz T7[-] :101.6/101.6 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 322/11291451 T2[0] : 0/0 T3[0] : 64962/64962 T4[0] : 399/399035 T5[0] : 4/4688 T6[0] : 0/0 T7[0] : 7623/7623 T8[0] : 765/76578
T1[+] : 166/5840226 T2[+] : 0/0 T3[+] : 33537/33537 T4[+] : 206/206739 T5[+] : 2/2423 T6[+] : 0/0 T7[+] : 3938/3938 T8[+] : 397/39741
T1[-] : 167/5855626 T2[-] : 0/0 T3[-] : 33793/33793 T4[-] : 206/206841 T5[-] : 2/2454 T6[-] : 0/0 T7[-] : 3943/3943 T8[-] : 397/39756
AVERAGE CURRENT
BCM x1 : 4.6240 uA BCM x3 : 4.6235 uA BCM x10: 4.6630 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1582 ppm BCM u3 : -1486 ppm BCM u10: -1475 ppm
BCM d1 : -1588 ppm BCM d3 : -1467 ppm BCM d10: -1469 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.000346 BCM u3 [0]:0.0003457 BCM u10[0]:0.0003483
BCM u1 [+]:0.0001793 BCM u3 [+]:0.0001792 BCM u10[+]:0.0001805
BCM u1 [-]:0.0001799 BCM u3 [-]:0.0001798 BCM u10[-]:0.0001811
BCM d1 [0]:0.0003456 BCM d3 [0]:0.0003458 BCM d10[0]:0.0003491
BCM d1 [+]:0.0001791 BCM d3 [+]:0.0001792 BCM d10[+]:0.0001809
BCM d1 [-]:0.0001797 BCM d3 [-]:0.0001798 BCM d10[-]:0.0001815
****************************
End-of-run EPICS data for Run Number 1167 at Fri May 16 10:03:49 EDT 2008
Wien angle : -33.7301
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.628596
Left Arm arm angle : 57.5003
Right Arm D1 momentum : 0.00440629
Right Arm arm angle : 104.999
HALLA:p : 1192.28
HALLA:dpp : -0.000235881
Tiefenbach Hall A energy : 1192.28
Left Arm Top VDC Current : 0.878906
Left Arm Bottom VDC Current : 3.95508
-----
Left Arm Q1 momentum : 0.628529
Left Arm Q1 power supply : 472.862
Left Arm Q1 gauss meter : 0.04056
Left Arm Q2 gauss meter : -0.10723
Left Arm Q2 power supply current : 270.7
Left Arm Q2 momentum : 0.628656
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 208.639
Left Arm D1 momentum : 0.628596
Left Arm D1 NMR : 0.264705
Left Arm Q3 gauss meter : -0.12689
Left Arm Q3 power supply current : 250.277
Left Arm Q3 momentum : 0.62865
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00410923
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -0.0001095
Right Arm Q2 power supply current : -0.000225541
Right Arm Q2 momentum : -6.873e-08
Right Arm Q2 gauss meter : -0.0002917
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0253355
Right Arm D1 momentum : 0.0044022
Right Arm D1 NMR : 0.301251
Right Arm Q3 power supply current : 0.000194288
Right Arm Q3 momentum : 0.000236763
Right Arm Q3 gauss meter : -0.0002586
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.619
BigBite Gaussmeter readback : 0.5486
-----
Average current of the two cavities : 4.68106
Current on Unser monitor : 17.5162
Current on Upstream bcm : 4.58772
Current on Downstream bcm : 4.77439
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 99.9992
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4616
MBSY1c Bdl : 297839
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.28
Hall A momentum orbit correction (dpp) : -0.000240746
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.28
Hall C energy (hallc_MeV) : 5710.49
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.937409
IPM1H04A.XPOS : -0.66467
IPM1H04A.YPOS : 0.712903
IPM1H04B.XPOS : -1.09151
IPM1H04B.YPOS : 1.62368
-----
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.302734
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : -0.353516
-----
Right Arm Collimator : -0.0081543
HacR_HPE1313A:0_Ch58 : -0.574219
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.842773
-----
Wien angle : -33.7301
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -782.27
Wien field : 22.411
Laser attenuation Hall A : 93
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.34037
SLI vert. size mm : 0
SLI y position : 2.35869
-----
Target : Carbon w/ Hole
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 1.07288e+07
Target type : 1.07288e+07
temperature loop 1(1) : 98.93
temperature loop 1(2) : 98.48
temperature loop 1(3) : 98.79
temperature loop 3(1) : 20
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 93.4
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.0813417
HPH H2 loop 3 : 53.0065
-----