Run Number: 21045
End of Run Comment:
Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=cavity tests, I = 1 uA
PRESCALE FACTORS:ps1=99999 ps2=99999 ps3=16777215 ps4=16777215 ps5=65535 ps6=65535 ps7=65535 ps8=20
EVENTS : [0]: 0 [+]: 2052 [-]: 2068
TIME : [0]: 0.017 mins [+]: 0.695 mins [-]: 0.696 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -83.83401 seconds
DEAD TIME: [0]: 0.00% [+]: 3.91% [-]: 3.35%
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/0.0 Hz T2[0] : 0.0/0.0 Hz T8[0] : 0.0/0.0 Hz
T1[+] : 0.0/0.0 Hz T2[+] : 0.0/0.0 Hz T8[+] :51.2/1024.0 Hz
T1[-] : 0.0/0.0 Hz T2[-] : 0.0/0.0 Hz T8[-] :51.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/0 T2[0] : 0/0 T8[0] : 0/0
T1[+] : 0/0 T2[+] : 0/0 T8[+] : 2135/42710
T1[-] : 0/0 T2[-] : 0/0 T8[-] : 2139/42792
AVERAGE CURRENT
BCM x1 : -0.1096uA BCM x3 : -0.0325uA BCM x10: -0.0169uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1886 ppm BCM u3 : -1293 ppm BCM u10: 1E+39 ppm
BCM d1 : -1685 ppm BCM d3 : -1267 ppm BCM d10: -1201 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:-1.531E-07 BCM u3 [0]:-4.809E-08 BCM u10[0]:-2.007E-08
BCM u1 [+]:3.515E-05 BCM u3 [+]:3.512E-05 BCM u10[+]:-8.373E-07
BCM u1 [-]:3.535E-05 BCM u3 [-]:3.528E-05 BCM u10[-]:-8.389E-07
BCM d1 [0]:-6.6E-08 BCM d3 [0]:-1.687E-08 BCM d10[0]:-1.364E-08
BCM d1 [+]:3.469E-05 BCM d3 [+]:3.501E-05 BCM d10[+]:3.521E-05
BCM d1 [-]:3.487E-05 BCM d3 [-]:3.517E-05 BCM d10[-]:3.536E-05
****************************
End-of-run EPICS data for Run Number 21045 at Thu May 29 13:22:29 EDT 2008
Wien angle : -13.5361
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.852618
Left Arm arm angle : -0.179
Right Arm D1 momentum : 0.00434088
Right Arm arm angle : 0.197
HALLA:p : 1192.13
HALLA:dpp : -0.000209005
Tiefenbach Hall A energy : 1192.13
Left Arm Top VDC Current : -1.75781
Left Arm Bottom VDC Current : -0.0488281
----
Left Arm Q1 momentum : 0.852425
Left Arm Q1 power supply : 641.36
Left Arm Q1 gauss meter : 0.0548
Left Arm Q2 gauss meter : -0.19349
Left Arm Q2 power supply current : 367.071
Left Arm Q2 momentum : 0.852465
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 284.301
Left Arm D1 momentum : 0.852618
Left Arm D1 NMR : 0.359131
Left Arm Q3 gauss meter : 0.172871
Left Arm Q3 power supply current : 339.421
Left Arm Q3 momentum : 0.852562
Left Arm Q3 power supply polarity : enabled
----
Right Arm Q1 momentum : 0.00533934
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -0.0001207
Right Arm Q2 power supply current : -3.69739e-05
Right Arm Q2 momentum : -8.59125e-08
Right Arm Q2 gauss meter : -0.0002995
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.026331
Right Arm D1 momentum : 0.00434115
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : -0.000145716
Right Arm Q3 momentum : -3.84984e-07
Right Arm Q3 gauss meter : -0.0002655
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.619
BigBite magnet magnet probe : 0.5631
-----
Average current of the two cavities : 0.84655
Current on Unser monitor : 14.2133
Current on Upstream bcm : 0.831854
Current on Downstream bcm : 0.861247
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 78.84
Hall C Current : 80.67
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.14
Hall A momentum orbit correction (dpp) : -0.000203992
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.14
Hall C energy (hallc_MeV) : 5710.89
Delta(E)/E width (MV_AI_DXWID) : 1.27276
IPM1C12.XPOS : 0.778982
IPM1H04A.XPOS : 0.305864
IPM1H04A.YPOS : -0.195121
IPM1H04B.XPOS : -2.03093
IPM1H04B.YPOS : -1.90365
-----
Left Arm Collimator : 0.871289
HacL_HPE1313A:0_Ch58 : -0.309082
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : -0.35791
-----
Right Arm Collimator : -0.0081543
HacR_HPE1313A:0_Ch58 : -0.570801
HacR_HPE1313A:0_Ch55 : 21.7773
HacR_HPE1313A:0_Ch54 : -0.849609
-----
Wien angle : -13.5361
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -315.67
Wien field : 8.9165
Laser attenuation Hall A : 65
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
Target OTR x-position : hlat:MV_AI_DXPOS --- Invalid channel name
Target OTR y-position : hlat:MV_AI_DYPOS --- Invalid channel name
Target OTR x-width : hlat:MV_AI_DXWID --- Invalid channel name
Target OTR y-width : hlat:MV_AI_DYWID --- Invalid channel name
Target OTR data valid flag : hlat:DataValid --- Invalid channel name
Target OTR In/Out : hlat:DataReason --- Invalid channel name
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.83354
SLI vert. size mm : 0
SLI y position : 3.25258
-----
Target : Carbon
Vacuum Pressure : 3.95931e-07
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 35.5
Encoder position : 9.10321e+06
Target type : 9.10321e+06
temperature loop 1(1) : 101.37
temperature loop 1(2) : 100.99
temperature loop 1(3) : 96.25
Heat exchange He2 : 91.3
temperature loop 2(1) : 86.42
temperature loop 2(2) : 90.38
temperature loop 2(3) : 119.99
Heat exchange D2 : 88.3
HPH He loop 1 : 0.0669839
HPH He loop 2 : 0.00123869