Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 14:32:38 on May 29, 2008

    Entry number 240294

    keyword=End_of_Run_21053
    ****************************
     Run Number: 21053
     End of Run Comment:
    Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=2.322,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.564,rightarm_theta=105,rightarm_colli=out,comment_text=1 uA, etc.
     
    
    PRESCALE FACTORS:ps1=99999   ps2=99999   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=20   
    
    EVENTS   : [0]: 0            [+]: 963          [-]: 961          
    TIME     : [0]: 0.017 mins  [+]: 0.338 mins  [-]: 0.338 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       -40.18868 seconds
    
    
    DEAD TIME: [0]:   0.00%      [+]:   7.18%      [-]:   7.43%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/0.0  Hz   T2[0] : 0.0/0.0  Hz   T8[0] : 0.0/0.0  Hz   
    T1[+] : 0.0/0.0  Hz   T2[+] : 0.0/0.0  Hz   T8[+] :51.2/1024.0 Hz   
    T1[-] : 0.0/0.0  Hz   T2[-] : 0.0/0.0  Hz   T8[-] :51.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/0        T2[0] :      0/0        T8[0] :      0/0        
    T1[+] :      0/0        T2[+] :      0/0        T8[+] :   1037/20751    
    T1[-] :      0/0        T2[-] :      0/0        T8[-] :   1038/20762    
    
    AVERAGE CURRENT
    BCM x1 : -0.1096uA  BCM x3 : -0.0325uA  BCM x10: -0.0169uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -7524 ppm     BCM u3 :    -1809 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :-1.247E+04 ppm     BCM d3 :    -2585 ppm     BCM d10:     1116 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-1.531E-07     BCM u3 [0]:-4.809E-08     BCM u10[0]:-2.007E-08     
    BCM u1 [+]:5.947E-07      BCM u3 [+]:5.693E-07      BCM u10[+]:-4.068E-07     
    BCM u1 [-]:6.041E-07      BCM u3 [-]:5.717E-07      BCM u10[-]:-4.07E-07      
    
    BCM d1 [0]:-6.6E-08       BCM d3 [0]:-1.687E-08     BCM d10[0]:-1.364E-08     
    BCM d1 [+]:5.317E-07      BCM d3 [+]:6.439E-07      BCM d10[+]:6.357E-07      
    BCM d1 [-]:5.454E-07      BCM d3 [-]:6.476E-07      BCM d10[-]:6.346E-07      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21053 at Thu May 29 14:32:04 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.852617
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.00433761
    Right Arm arm angle : 0.197
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : 3.36914
    Left Arm Bottom VDC Current : -1.61133
    ----
    Left Arm Q1 momentum : 0.852496
    Left Arm Q1 power supply : 641.36
    Left Arm Q1 gauss meter : 0.0548
    Left Arm Q2 gauss meter : -0.19349
    Left Arm Q2 power supply current : 367.075
    Left Arm Q2 momentum : 0.852474
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 284.303
    Left Arm D1 momentum : 0.852617
    Left Arm D1 NMR : 0.359131
    Left Arm Q3 gauss meter : 0.172871
    Left Arm Q3 power supply current : 339.424
    Left Arm Q3 momentum : 0.852571
    Left Arm Q3 power supply polarity : enabled
    ----
    Right Arm Q1 momentum : 0.00447508
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001044
    Right Arm Q2 power supply current : -0.000218146
    Right Arm Q2 momentum : -5.06884e-07
    Right Arm Q2 gauss meter : -0.0002945
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0273724
    Right Arm D1 momentum : 0.00433761
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 4.48357e-05
    Right Arm Q3 momentum : -2.81696e-07
    Right Arm Q3 gauss meter : -0.0002656
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite magnet magnet probe : 0.5633
    -----
    Average current of the two cavities : 0.0248889
    Current on Unser monitor : 13.9933
    Current on Upstream bcm : 0.0350533
    Current on Downstream bcm : 0.0147245
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.135004
    Hall C Current : 0
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5711.11
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.309082
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.357422
    -----
    Right Arm Collimator : -0.00830078
    HacR_HPE1313A:0_Ch58 : -0.570312
    HacR_HPE1313A:0_Ch55 : 21.7285
    HacR_HPE1313A:0_Ch54 : -0.849121
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 120
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : hlat:MV_AI_DXPOS --- Invalid channel name
    Target OTR y-position : hlat:MV_AI_DYPOS --- Invalid channel name
    Target OTR x-width : hlat:MV_AI_DXWID --- Invalid channel name
    Target OTR y-width : hlat:MV_AI_DYWID --- Invalid channel name
    Target OTR data valid flag : hlat:DataValid --- Invalid channel name
    Target OTR In/Out : hlat:DataReason --- Invalid channel name
    Arc OTR x-position : -10.5973
    Arc OTR y-position : 5
    Arc OTR x-width : 0
    Arc OTR y-width : -0
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.2
    SLI vert. size mm : 0
    SLI y position : 0.803756
    -----
    Target : Carbon
    Vacuum Pressure : 4.06789e-07
    fan frequency loop 1 : 0
    fan frequency loop 2 : 0
    fan frequency loop 3 : 36
    Encoder position : 9.10321e+06
    Target type : 9.10321e+06
    temperature loop 1(1) : 101.52
    temperature loop 1(2) : 101.14
    temperature loop 1(3) : 96.45
    Heat exchange He2 : 91.4
    temperature loop 2(1) : 86.33
    temperature loop 2(2) : 90.25
    temperature loop 2(3) : 119.99
    Heat exchange D2 : 88.4
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.0177944