NEXT
User name a-onl
Log entry time 14:47:27 on May 29, 2008
Entry number 240308
keyword=End_of_Run_1697
****************************
Run Number: 1697
End of Run Comment:
Run_type=Calibration,target_type=Loop 3 LH2 15 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.7366,leftarm_theta=51,leftarm_colli=out,bbarm_i=700,bbarm_theta=40.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=BPM pedestal run
PRESCALE FACTORS:ps1=3000 ps2=16777215 ps3=450 ps4=4500 ps5=1 ps6=65535 ps7=65535 ps8=10
EVENTS : [0]: 1123889 [+]: 553696 [-]: 553584
TIME : [0]: 181.423 mins [+]: 89.403 mins [-]: 89.411 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -15.10626 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 0.04% [+]: 0.07% [-]: 0.09%
TRIGGER RATES: PRES/REAL
T1[0] : 0.2/641.9 Hz T2[0] : 0.0/0.0 Hz T3[0] : 0.2/102.1 Hz T4[0] : 0.4/1609.1 Hz T5[0] : 0.1/0.1 Hz T6[0] : 0.0/0.0 Hz T7[0] : 0.0/0.0 Hz T8[0] :102.4/1024.0 Hz
T1[+] : 0.2/641.3 Hz T2[+] : 0.0/0.0 Hz T3[+] : 0.2/102.0 Hz T4[+] : 0.4/1608.6 Hz T5[+] : 0.1/0.1 Hz T6[+] : 0.0/0.0 Hz T7[+] : 0.0/0.0 Hz T8[+] :102.4/1024.0 Hz
T1[-] : 0.2/642.0 Hz T2[-] : 0.0/0.0 Hz T3[-] : 0.2/102.1 Hz T4[-] : 0.4/1609.1 Hz T5[-] : 0.1/0.1 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] :102.4/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 2328/6986928 T2[0] : 0/0 T3[0] : 2470/1111855 T4[0] : 3892/17515242 T5[0] : 997/997 T6[0] : 0/0 T7[0] : 0/0 T8[0] :1114663/11146639
T1[+] : 1146/3440224 T2[+] : 0/0 T3[+] : 1216/547402 T4[+] : 1917/8628914 T5[+] : 510/510 T6[+] : 0/0 T7[+] : 0/0 T8[+] : 549289/5492897
T1[-] : 1148/3444016 T2[-] : 0/0 T3[-] : 1217/547935 T4[-] : 1918/8632443 T5[-] : 471/471 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 549343/5493430
AVERAGE CURRENT
BCM x1 : 1.8822 uA BCM x3 : 1.8839 uA BCM x10: 0.9388 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1046 ppm BCM u3 : -883 ppm BCM u10: 1E+39 ppm
BCM d1 : -1083 ppm BCM d3 : -874.4 ppm BCM d10: -838.2 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.02058 BCM u3 [0]:0.02057 BCM u10[0]:-0.0002021
BCM u1 [+]:0.01013 BCM u3 [+]:0.01012 BCM u10[+]:-9.957E-05
BCM u1 [-]:0.01015 BCM u3 [-]:0.01014 BCM u10[-]:-9.958E-05
BCM d1 [0]:0.0204 BCM d3 [0]:0.02045 BCM d10[0]:0.02064
BCM d1 [+]:0.01004 BCM d3 [+]:0.01006 BCM d10[+]:0.01016
BCM d1 [-]:0.01006 BCM d3 [-]:0.01008 BCM d10[-]:0.01018
****************************
End-of-run EPICS data for Run Number 1697 at Thu May 29 14:47:17 EDT 2008
Wien angle : -13.5361
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.852618
Left Arm arm angle : -0.179
Right Arm D1 momentum : 0.0043695
Right Arm arm angle : 0.197
HALLA:p : 1192.38
HALLA:dpp : 0
Tiefenbach Hall A energy : 1192.38
Left Arm Top VDC Current : 5.17578
Left Arm Bottom VDC Current : 3.56445
-----
Left Arm Q1 momentum : 0.852496
Left Arm Q1 power supply : 641.36
Left Arm Q1 gauss meter : 0.05479
Left Arm Q2 gauss meter : -0.19345
Left Arm Q2 power supply current : 367.07
Left Arm Q2 momentum : 0.852462
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 284.303
Left Arm D1 momentum : 0.852617
Left Arm D1 NMR : 0.35913
Left Arm Q3 gauss meter : 0.172871
Left Arm Q3 power supply current : 339.42
Left Arm Q3 momentum : 0.852559
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00414104
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -9.81e-05
Right Arm Q2 power supply current : -0.000262515
Right Arm Q2 momentum : -5.75614e-07
Right Arm Q2 gauss meter : -0.000296
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.026571
Right Arm D1 momentum : 0.00435424
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : -5.60446e-05
Right Arm Q3 momentum : 0.000193664
Right Arm Q3 gauss meter : -0.0002654
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.619
BigBite Gaussmeter readback : 0.5634
-----
Average current of the two cavities : 0.0258402
Current on Unser monitor : 14.3529
Current on Upstream bcm : 0.0357605
Current on Downstream bcm : 0.0159649
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 78.2793
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.38
Hall C energy (hallc_MeV) : 5710.98
Delta(E)/E width (MV_AI_DXWID) : 1.26679
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871191
HacL_HPE1313A:0_Ch58 : -0.309082
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : -0.35791
-----
Right Arm Collimator : -0.00874023
HacR_HPE1313A:0_Ch58 : -0.570801
HacR_HPE1313A:0_Ch55 : 21.6797
HacR_HPE1313A:0_Ch54 : -0.848145
-----
Wien angle : -13.5361
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -315.67
Wien field : 8.9165
Laser attenuation Hall A : 120
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.44596
SLI vert. size mm : 0
SLI y position : 3.51549
-----
Target : Carbon
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 9.10321e+06
Target type : 9.10321e+06
temperature loop 1(1) : 101.56
temperature loop 1(2) : 101.17
temperature loop 1(3) : 96.48
temperature loop 3(1) : 20
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 91.4
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.132774
HPH H2 loop 3 : 98.2212
-----