Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 15:08:12 on May 29, 2008

    Entry number 240312

    keyword=End_of_Run_1698
    ****************************
     Run Number: 1698
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8526,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=15uA Production, kinematic 7 delta=+2
     
    
    PRESCALE FACTORS:ps1=20000   ps2=16777215   ps3=30   ps4=2000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 85111        [+]: 41958        [-]: 41889        
    TIME     : [0]: 9.449 mins  [+]: 4.689 mins  [-]: 4.688 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.68825 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   4.32%      [+]:   4.78%      [-]:   5.17%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :35.2/704962.3 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :21.1/633.3 Hz   T4[0] : 5.6/11112.0 Hz   T5[0] :87.7/87.7 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :35.2/704964.4 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :21.1/632.2 Hz   T4[+] : 5.5/11100.2 Hz   T5[+] :87.4/87.4 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :35.3/705830.2 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :21.2/634.9 Hz   T4[-] : 5.6/11136.2 Hz   T5[-] :87.8/87.8 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  19982/399658565  T2[0] :      0/0        T3[0] :  11968/359055   T4[0] :   3149/6299628  T5[0] :  49720/49720    T6[0] :      0/0        T7[0] :      0/0        T8[0] :   5805/580528   
    T1[+] :   9917/198345585  T2[+] :      0/0        T3[+] :   5928/177865   T4[+] :   1561/3123111  T5[+] :  24604/24604    T6[+] :      0/0        T7[+] :      0/0        T8[+] :   2881/288108   
    T1[-] :   9925/198516820  T2[-] :      0/0        T3[-] :   5952/178560   T4[-] :   1566/3132087  T5[-] :  24680/24680    T6[-] :      0/0        T7[-] :      0/0        T8[-] :   2880/288003   
    
    AVERAGE CURRENT
    BCM x1 : 13.2383uA  BCM x3 : 13.2403uA  BCM x10: 6.6510 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -807.5 ppm     BCM u3 :   -778.3 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -819.9 ppm     BCM d3 :   -770.5 ppm     BCM d10:   -771.9 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.007531       BCM u3 [0]:0.007532       BCM u10[0]:-1.053E-05     
    BCM u1 [+]:0.003736       BCM u3 [+]:0.003737       BCM u10[+]:-5.225E-06     
    BCM u1 [-]:0.003741       BCM u3 [-]:0.003742       BCM u10[-]:-5.224E-06     
    
    BCM d1 [0]:0.00748        BCM d3 [0]:0.007481       BCM d10[0]:0.007552       
    BCM d1 [+]:0.003711       BCM d3 [+]:0.003712       BCM d10[+]:0.003747       
    BCM d1 [-]:0.003716       BCM d3 [-]:0.003716       BCM d10[-]:0.003752       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1698 at Thu May 29 15:08:03 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.852617
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.00439593
    Right Arm arm angle : 0.197
    HALLA:p : 1192.1
    HALLA:dpp : -0.000238385
    Tiefenbach Hall A energy : 1192.1
    Left Arm Top VDC Current : 4.19922
    Left Arm Bottom VDC Current : 4.24805
    -----
    Left Arm Q1 momentum : 0.852425
    Left Arm Q1 power supply : 641.306
    Left Arm Q1 gauss meter : 0.05481
    Left Arm Q2 gauss meter : -0.19347
    Left Arm Q2 power supply current : 367.072
    Left Arm Q2 momentum : 0.852468
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 284.306
    Left Arm D1 momentum : 0.852617
    Left Arm D1 NMR : 0.35913
    Left Arm Q3 gauss meter : 0.172886
    Left Arm Q3 power supply current : 339.423
    Left Arm Q3 momentum : 0.852567
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00383881
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.24e-05
    Right Arm Q2 power supply current : -0.000140501
    Right Arm Q2 momentum : -4.03789e-07
    Right Arm Q2 gauss meter : -0.0003043
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0269311
    Right Arm D1 momentum : 0.00439811
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 3.7363e-06
    Right Arm Q3 momentum : 0.000194783
    Right Arm Q3 gauss meter : -0.0002652
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.5633
    -----
    Average current of the two cavities : 14.4091
    Current on Unser monitor : 27.6848
    Current on Upstream bcm : 14.2147
    Current on Downstream bcm : 14.6035
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 102.73
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.11
    Hall A momentum orbit correction (dpp) : -0.000226325
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.11
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 1.24212
    IPM1C12.XPOS : 0.927117
    IPM1H04A.XPOS : -1.1045
    IPM1H04A.YPOS : 1.11319
    IPM1H04B.XPOS : -1.77949
    IPM1H04B.YPOS : 1.87819
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.30957
    HacL_HPE1313A:0_Ch55 : 23.1445
    HacL_HPE1313A:0_Ch54 : -0.357422
    -----
    Right Arm Collimator : -0.00825195
    HacR_HPE1313A:0_Ch58 : -0.570312
    HacR_HPE1313A:0_Ch55 : 21.8262
    HacR_HPE1313A:0_Ch54 : -0.848633
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 127
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.581366
    SLI vert. size mm : 0
    SLI y position : 2.63662
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 35.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 101.34
    temperature loop 1(2) : 100.95
    temperature loop 1(3) : 96.3
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.4
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 48.9953
    -----