NEXT
User name a-onl
Log entry time 15:29:44 on May 29, 2008
Entry number 240314
keyword=End_of_Run_1699
****************************
Run Number: 1699
End of Run Comment:
Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8526,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=15uA Production, kinematic 7 delta=+2
PRESCALE FACTORS:ps1=20000 ps2=16777215 ps3=250 ps4=3000 ps5=1 ps6=65535 ps7=65535 ps8=100
EVENTS : [0]: 447624 [+]: 220618 [-]: 220371
TIME : [0]: 6.722 mins [+]: 3.347 mins [-]: 3.346 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.66638 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 36.40% [+]: 36.51% [-]: 36.30%
TRIGGER RATES: PRES/REAL
T1[0] :20.8/416946.1 Hz T2[0] : 0.0/0.0 Hz T3[0] :10.6/2659.2 Hz T4[0] : 3.1/9453.0 Hz T5[0] :1707.1/1707.1 Hz T6[0] : 0.0/0.0 Hz T7[0] : 0.0/0.0 Hz T8[0] :10.2/1024.0 Hz
T1[+] :20.6/412447.1 Hz T2[+] : 0.0/0.0 Hz T3[+] :10.5/2636.0 Hz T4[+] : 3.1/9368.8 Hz T5[+] :1693.0/1693.0 Hz T6[+] : 0.0/0.0 Hz T7[+] : 0.0/0.0 Hz T8[+] :10.2/1024.0 Hz
T1[-] :20.6/412757.2 Hz T2[-] : 0.0/0.0 Hz T3[-] :10.5/2626.4 Hz T4[-] : 3.1/9367.8 Hz T5[-] :1685.5/1685.5 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 8408/168167704 T2[0] : 0/0 T3[0] : 4290/1072522 T4[0] : 1270/3812698 T5[0] : 688518/688518 T6[0] : 0/0 T7[0] : 0/0 T8[0] : 4130/413012
T1[+] : 4140/82816083 T2[+] : 0/0 T3[+] : 2117/529287 T4[+] : 627/1881174 T5[+] : 339941/339941 T6[+] : 0/0 T7[+] : 0/0 T8[+] : 2056/205611
T1[-] : 4143/82873912 T2[-] : 0/0 T3[-] : 2109/527326 T4[-] : 626/1880869 T5[-] : 338412/338412 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 2056/205600
AVERAGE CURRENT
BCM x1 : 7.8016 uA BCM x3 : 7.8035 uA BCM x10: 3.9163 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -518.7 ppm BCM u3 : -460.6 ppm BCM u10: 1E+39 ppm
BCM d1 : -522.6 ppm BCM d3 : -451.7 ppm BCM d10: -450 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.003158 BCM u3 [0]:0.003158 BCM u10[0]:-7.479E-06
BCM u1 [+]:0.001555 BCM u3 [+]:0.001555 BCM u10[+]:-3.723E-06
BCM u1 [-]:0.001556 BCM u3 [-]:0.001556 BCM u10[-]:-3.723E-06
BCM d1 [0]:0.003136 BCM d3 [0]:0.003137 BCM d10[0]:0.003167
BCM d1 [+]:0.001544 BCM d3 [+]:0.001545 BCM d10[+]:0.001559
BCM d1 [-]:0.001546 BCM d3 [-]:0.001546 BCM d10[-]:0.001561
****************************
End-of-run EPICS data for Run Number 1699 at Thu May 29 15:29:34 EDT 2008
Wien angle : -13.5361
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.852614
Left Arm arm angle : 46.9997
Right Arm D1 momentum : 0.0043387
Right Arm arm angle : 0.197
HALLA:p : 1192.38
HALLA:dpp : 0
Tiefenbach Hall A energy : 1192.38
Left Arm Top VDC Current : 1.07422
Left Arm Bottom VDC Current : 4.44336
-----
Left Arm Q1 momentum : 0.852496
Left Arm Q1 power supply : 641.36
Left Arm Q1 gauss meter : 0.05481
Left Arm Q2 gauss meter : -0.19347
Left Arm Q2 power supply current : 367.071
Left Arm Q2 momentum : 0.852464
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 284.302
Left Arm D1 momentum : 0.852614
Left Arm D1 NMR : 0.359129
Left Arm Q3 gauss meter : 0.172891
Left Arm Q3 power supply current : 339.421
Left Arm Q3 momentum : 0.852563
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.0054666
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -0.0001258
Right Arm Q2 power supply current : -0.000343858
Right Arm Q2 momentum : -7.98986e-07
Right Arm Q2 gauss meter : -0.0003012
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.027743
Right Arm D1 momentum : 0.0043387
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : -0.000130771
Right Arm Q3 momentum : -3.28645e-07
Right Arm Q3 gauss meter : -0.0002655
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.619
BigBite Gaussmeter readback : 0.5633
-----
Average current of the two cavities : 0.0250432
Current on Unser monitor : 14.3025
Current on Upstream bcm : 0.0353748
Current on Downstream bcm : 0.0147117
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00272248
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.38
Hall C energy (hallc_MeV) : 5711.11
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871191
HacL_HPE1313A:0_Ch58 : -0.303223
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : -0.288086
-----
Right Arm Collimator : -0.00839844
HacR_HPE1313A:0_Ch58 : -0.569824
HacR_HPE1313A:0_Ch55 : 21.7773
HacR_HPE1313A:0_Ch54 : -0.847656
-----
Wien angle : -13.5361
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -315.67
Wien field : 8.9165
Laser attenuation Hall A : 75
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.72919
SLI vert. size mm : 0
SLI y position : 0.443193
-----
Target : L3 6cm
fan frequency loop 1 : 0
fan frequency loop 3 : 36.5
Encoder position : 2.06493e+07
Target type : 2.06493e+07
temperature loop 1(1) : 101.15
temperature loop 1(2) : 100.77
temperature loop 1(3) : 96.2
temperature loop 3(1) : 20
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 91.5
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.0424476
HPH H2 loop 3 : 100.768
-----