Log entry time 16:23:01 on May 29, 2008
Entry number 240323
keyword=End_of_Run_1701
****************************
Run Number: 1701
End of Run Comment:
Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8526,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=15uA Production, kinematic 7 delta=+2
some shower blocks were turned off during the run.
PRESCALE FACTORS:ps1=5000 ps2=16777215 ps3=250 ps4=3000 ps5=1 ps6=65535 ps7=65535 ps8=100
EVENTS : [0]: 2272343 [+]: 1117941 [-]: 1120695
TIME : [0]: 21.917 mins [+]: 10.832 mins [-]: 10.832 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -5.64551 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 32.33% [+]: 32.58% [-]: 32.56%
TRIGGER RATES: PRES/REAL
T1[0] :19.3/96486.8 Hz T2[0] : 0.0/0.0 Hz T3[0] :17.9/4483.5 Hz T4[0] : 5.1/15363.4 Hz T5[0] :2511.8/2511.8 Hz T6[0] : 0.0/0.0 Hz T7[0] : 0.0/0.0 Hz T8[0] :10.2/1024.0 Hz
T1[+] :19.3/96403.0 Hz T2[+] : 0.0/0.0 Hz T3[+] :17.9/4481.8 Hz T4[+] : 5.1/15360.8 Hz T5[+] :2509.4/2509.4 Hz T6[+] : 0.0/0.0 Hz T7[+] : 0.0/0.0 Hz T8[+] :10.2/1024.0 Hz
T1[-] :19.3/96562.1 Hz T2[-] : 0.0/0.0 Hz T3[-] :18.0/4488.1 Hz T4[-] : 5.1/15374.6 Hz T5[-] :2514.9/2514.9 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 25376/126881549 T2[0] : 0/0 T3[0] : 23583/5895891 T4[0] : 6734/20203071 T5[0] :3303098/3303098 T6[0] : 0/0 T7[0] : 0/0 T8[0] : 13465/1346575
T1[+] : 12531/62656768 T2[+] : 0/0 T3[+] : 11651/2912901 T4[+] : 3327/9983704 T5[+] :1630994/1630994 T6[+] : 0/0 T7[+] : 0/0 T8[+] : 6655/665545
T1[-] : 12551/62757265 T2[-] : 0/0 T3[-] : 11667/2916868 T4[-] : 3330/9992189 T5[-] :1634502/1634502 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 6655/665514
AVERAGE CURRENT
BCM x1 : 13.1571uA BCM x3 : 13.1595uA BCM x10: 6.6170 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -664.6 ppm BCM u3 : -631.8 ppm BCM u10: 1E+39 ppm
BCM d1 : -667 ppm BCM d3 : -623.5 ppm BCM d10: -625.4 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.01734 BCM u3 [0]:0.01735 BCM u10[0]:-2.438E-05
BCM u1 [+]:0.008569 BCM u3 [+]:0.008571 BCM u10[+]:-1.205E-05
BCM u1 [-]:0.00858 BCM u3 [-]:0.008581 BCM u10[-]:-1.205E-05
BCM d1 [0]:0.01726 BCM d3 [0]:0.01726 BCM d10[0]:0.01743
BCM d1 [+]:0.008528 BCM d3 [+]:0.00853 BCM d10[+]:0.008611
BCM d1 [-]:0.008539 BCM d3 [-]:0.00854 BCM d10[-]:0.008621
****************************
End-of-run EPICS data for Run Number 1701 at Thu May 29 16:22:51 EDT 2008
Wien angle : -13.5361
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.852615
Left Arm arm angle : 46.9997
Right Arm D1 momentum : 0.00438176
Right Arm arm angle : 0.197
HALLA:p : 1192.1
HALLA:dpp : -0.000239437
Tiefenbach Hall A energy : 1192.1
Left Arm Top VDC Current : -1.36719
Left Arm Bottom VDC Current : -1.61133
-----
Left Arm Q1 momentum : 0.852496
Left Arm Q1 power supply : 641.36
Left Arm Q1 gauss meter : 0.05481
Left Arm Q2 gauss meter : -0.19349
Left Arm Q2 power supply current : 367.071
Left Arm Q2 momentum : 0.852463
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 284.304
Left Arm D1 momentum : 0.852615
Left Arm D1 NMR : 0.359129
Left Arm Q3 gauss meter : 0.172869
Left Arm Q3 power supply current : 339.421
Left Arm Q3 momentum : 0.852561
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00414634
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -0.0001108
Right Arm Q2 power supply current : -0.000125711
Right Arm Q2 momentum : -4.20971e-07
Right Arm Q2 gauss meter : -0.000303
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.026511
Right Arm D1 momentum : 0.00438176
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : -8.21987e-05
Right Arm Q3 momentum : -3.84984e-07
Right Arm Q3 gauss meter : -0.0002656
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.603
BigBite Gaussmeter readback : 0.5634
-----
Average current of the two cavities : 14.6052
Current on Unser monitor : 28.3664
Current on Upstream bcm : 14.3624
Current on Downstream bcm : 14.848
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 102.482
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.1
Hall A momentum orbit correction (dpp) : -0.000240852
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.1
Hall C energy (hallc_MeV) : 5710.96
Delta(E)/E width (MV_AI_DXWID) : 1.26941
IPM1C12.XPOS : 0.947264
IPM1H04A.XPOS : -1.13447
IPM1H04A.YPOS : 1.11599
IPM1H04B.XPOS : -1.80406
IPM1H04B.YPOS : 1.88316
-----
Left Arm Collimator : 0.871191
HacL_HPE1313A:0_Ch58 : -0.303223
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : -0.291504
-----
Right Arm Collimator : -0.0081543
HacR_HPE1313A:0_Ch58 : -0.569824
HacR_HPE1313A:0_Ch55 : 21.7285
HacR_HPE1313A:0_Ch54 : -0.848145
-----
Wien angle : -13.5361
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -315.67
Wien field : 8.9165
Laser attenuation Hall A : 128
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.00621
SLI vert. size mm : 0
SLI y position : 3.27512
-----
Target : L3 6cm
fan frequency loop 1 : 0
fan frequency loop 3 : 35.5
Encoder position : 2.06493e+07
Target type : 2.06493e+07
temperature loop 1(1) : 100.83
temperature loop 1(2) : 100.45
temperature loop 1(3) : 96.07
temperature loop 3(1) : 19.99
temperature loop 3(2) : 19.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 91.5
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.132774
HPH H2 loop 3 : 57.5622
-----