NEXT
User name a-onl
Log entry time 18:53:56 on May 29, 2008
Entry number 240336
keyword=End_of_Run_1706
****************************
Run Number: 1706
End of Run Comment:
Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8526,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=15uA Production, kinematic 7 delta=+2 production 19uA
MCC notify that beam is going down for ~20min
PRESCALE FACTORS:ps1=4500 ps2=16777215 ps3=250 ps4=3000 ps5=1 ps6=65535 ps7=65535 ps8=100
EVENTS : [0]: 4803515 [+]: 2365702 [-]: 2366802
TIME : [0]: 64.288 mins [+]: 31.713 mins [-]: 31.710 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -8.96995 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 35.61% [+]: 35.58% [-]: 35.63%
TRIGGER RATES: PRES/REAL
T1[0] :11.2/50436.8 Hz T2[0] : 0.0/0.0 Hz T3[0] :14.8/3709.6 Hz T4[0] : 4.4/13105.5 Hz T5[0] :1901.5/1901.5 Hz T6[0] : 0.0/0.0 Hz T7[0] : 0.0/0.0 Hz T8[0] :10.2/1024.0 Hz
T1[+] :11.2/50331.7 Hz T2[+] : 0.0/0.0 Hz T3[+] :14.8/3703.7 Hz T4[+] : 4.4/13086.8 Hz T5[+] :1897.6/1897.6 Hz T6[+] : 0.0/0.0 Hz T7[+] : 0.0/0.0 Hz T8[+] :10.2/1024.0 Hz
T1[-] :11.2/50404.9 Hz T2[-] : 0.0/0.0 Hz T3[-] :14.8/3705.6 Hz T4[-] : 4.4/13094.1 Hz T5[-] :1900.2/1900.2 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 43233/194549095 T2[0] : 0/0 T3[0] : 57235/14308998 T4[0] : 16850/50551588 T5[0] :7334505/7334505 T6[0] : 0/0 T7[0] : 0/0 T8[0] : 39498/3949863
T1[+] : 21282/95769894 T2[+] : 0/0 T3[+] : 28189/7047358 T4[+] : 8300/24901182 T5[+] :3610724/3610724 T6[+] : 0/0 T7[+] : 0/0 T8[+] : 19484/1948441
T1[-] : 21311/95900242 T2[-] : 0/0 T3[-] : 28201/7050315 T4[-] : 8304/24912854 T5[-] :3615285/3615285 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 19482/1948260
AVERAGE CURRENT
BCM x1 : 10.9816uA BCM x3 : 10.9834uA BCM x10: 5.5207 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -672.1 ppm BCM u3 : -632.7 ppm BCM u10: 1E+39 ppm
BCM d1 : -677.1 ppm BCM d3 : -624.1 ppm BCM d10: -624.1 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.04244 BCM u3 [0]:0.04245 BCM u10[0]:-7.153E-05
BCM u1 [+]:0.02089 BCM u3 [+]:0.0209 BCM u10[+]:-3.529E-05
BCM u1 [-]:0.02092 BCM u3 [-]:0.02092 BCM u10[-]:-3.528E-05
BCM d1 [0]:0.04228 BCM d3 [0]:0.04228 BCM d10[0]:0.04266
BCM d1 [+]:0.02081 BCM d3 [+]:0.02082 BCM d10[+]:0.021
BCM d1 [-]:0.02084 BCM d3 [-]:0.02084 BCM d10[-]:0.02103
****************************
End-of-run EPICS data for Run Number 1706 at Thu May 29 18:53:47 EDT 2008
Wien angle : -13.5361
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.852615
Left Arm arm angle : 46.9997
Right Arm D1 momentum : 0.00437658
Right Arm arm angle : 0.197
HALLA:p : 1192.38
HALLA:dpp : 0
Tiefenbach Hall A energy : 1192.38
Left Arm Top VDC Current : 5.22461
Left Arm Bottom VDC Current : 1.2207
-----
Left Arm Q1 momentum : 0.852496
Left Arm Q1 power supply : 641.36
Left Arm Q1 gauss meter : 0.05481
Left Arm Q2 gauss meter : -0.1935
Left Arm Q2 power supply current : 367.131
Left Arm Q2 momentum : 0.852605
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 284.303
Left Arm D1 momentum : 0.852615
Left Arm D1 NMR : 0.359129
Left Arm Q3 gauss meter : 0.172877
Left Arm Q3 power supply current : 339.422
Left Arm Q3 momentum : 0.852563
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00393425
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -8.45e-05
Right Arm Q2 power supply current : -0.000310581
Right Arm Q2 momentum : -7.21665e-07
Right Arm Q2 gauss meter : -0.0003047
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0282549
Right Arm D1 momentum : 0.00438885
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 7.47261e-05
Right Arm Q3 momentum : 0.000190865
Right Arm Q3 gauss meter : -0.0002657
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.603
BigBite Gaussmeter readback : 0.5631
-----
Average current of the two cavities : 0.0259756
Current on Unser monitor : 13.1125
Current on Upstream bcm : 0.0372396
Current on Downstream bcm : 0.014637
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00234863
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.38
Hall C energy (hallc_MeV) : 5711.11
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.87124
HacL_HPE1313A:0_Ch58 : -0.302246
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : -0.29541
-----
Right Arm Collimator : -0.00810547
HacR_HPE1313A:0_Ch58 : -0.570312
HacR_HPE1313A:0_Ch55 : 21.7773
HacR_HPE1313A:0_Ch54 : -0.847656
-----
Wien angle : -13.5361
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -315.67
Wien field : 8.9165
Laser attenuation Hall A : 75
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.29689
SLI vert. size mm : 0
SLI y position : 2.32113
-----
Target : L3 6cm
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 2.06493e+07
Target type : 2.06493e+07
temperature loop 1(1) : 100.46
temperature loop 1(2) : 100.08
temperature loop 1(3) : 95.72
temperature loop 3(1) : 20
temperature loop 3(2) : 19.98
temperature loop 3(3) : 29.99
Heat exchange LH2 : 91.3
Heat exchange LH2 : 20
HPH H2 loop 1 : 0.0540192
HPH H2 loop 3 : 104.389
-----