    keyword=End_of_Run_1711
    ****************************
     Run Number: 1711
     End of Run Comment:
    Run_type=Other,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8526,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Production LH2 6cm at 19uA
     
    
    PRESCALE FACTORS:ps1=4500   ps2=16777215   ps3=300   ps4=4200   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5005696      [+]: 2465092      [-]: 2466579      
    TIME     : [0]: 56.083 mins  [+]: 27.659 mins  [-]: 27.660 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.33153 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  36.31%      [+]:  36.37%      [-]:  36.49%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.6/61001.3 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :14.9/4482.4 Hz   T4[0] : 3.7/15536.5 Hz   T5[0] :2301.7/2301.7 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :13.6/60986.3 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :14.9/4482.1 Hz   T4[+] : 3.7/15543.4 Hz   T5[+] :2300.3/2300.3 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :13.6/61084.6 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :15.0/4488.1 Hz   T4[-] : 3.7/15545.3 Hz   T5[-] :2305.9/2305.9 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  45614/205266561  T2[0] :      0/0        T3[0] :  50276/15083083  T4[0] :  12447/52279650  T5[0] :7745073/7745073  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  34457/3445711  
    T1[+] :  22491/101210718  T2[+] :      0/0        T3[+] :  24794/7438274  T4[+] :   6141/25795247  T5[+] :3817420/3817420  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  16993/1699393  
    T1[-] :  22528/101376888  T2[-] :      0/0        T3[-] :  24828/7448451  T4[-] :   6142/25799198  T5[-] :3826973/3826973  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  16994/1699444  
    
    AVERAGE CURRENT
    BCM x1 : 13.3504uA  BCM x3 : 13.3503uA  BCM x10: 6.7041 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -817.1 ppm     BCM u3 :   -779.4 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -824.5 ppm     BCM d3 :   -768.7 ppm     BCM d10:   -772.6 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.04507        BCM u3 [0]:0.04507        BCM u10[0]:-6.246E-05     
    BCM u1 [+]:0.02222        BCM u3 [+]:0.02222        BCM u10[+]:-3.081E-05     
    BCM u1 [-]:0.02226        BCM u3 [-]:0.02226        BCM u10[-]:-3.08E-05      
    
    BCM d1 [0]:0.04478        BCM d3 [0]:0.04478        BCM d10[0]:0.04518        
    BCM d1 [+]:0.02208        BCM d3 [+]:0.02208        BCM d10[+]:0.02228        
    BCM d1 [-]:0.02212        BCM d3 [-]:0.02211        BCM d10[-]:0.02231        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1711 at Fri May 30 03:53:17 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.852617
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.0043496
    Right Arm arm angle : 0.197
    HALLA:p : 1192.13
    HALLA:dpp : -0.000209906
    Tiefenbach Hall A energy : 1192.13
    Left Arm Top VDC Current : -2.09961
    Left Arm Bottom VDC Current : 1.31836
    -----
    Left Arm Q1 momentum : 0.852496
    Left Arm Q1 power supply : 641.36
    Left Arm Q1 gauss meter : 0.05481
    Left Arm Q2 gauss meter : -0.19356
    Left Arm Q2 power supply current : 367.208
    Left Arm Q2 momentum : 0.852784
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 284.302
    Left Arm D1 momentum : 0.852617
    Left Arm D1 NMR : 0.35913
    Left Arm Q3 gauss meter : 0.172875
    Left Arm Q3 power supply current : 339.421
    Left Arm Q3 momentum : 0.852563
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00433722
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001065
    Right Arm Q2 power supply current : -0.000192264
    Right Arm Q2 momentum : -4.46745e-07
    Right Arm Q2 gauss meter : -0.000296
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0270829
    Right Arm D1 momentum : 0.00434388
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -1.12089e-05
    Right Arm Q3 momentum : -2.81696e-08
    Right Arm Q3 gauss meter : -0.0002654
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5634
    -----
    Average current of the two cavities : 19.8931
    Current on Unser monitor : 32.0491
    Current on Upstream bcm : 19.5184
    Current on Downstream bcm : 20.2679
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 97.3748
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.23
    Hall A momentum orbit correction (dpp) : -0.000128114
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.23
    Hall C energy (hallc_MeV) : 5710.94
    Delta(E)/E width (MV_AI_DXWID) : 1.27599
    IPM1C12.XPOS : 0.850071
    IPM1H04A.XPOS : -1.14046
    IPM1H04A.YPOS : 1.13165
    IPM1H04B.XPOS : -1.80798
    IPM1H04B.YPOS : 1.89756
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.303223
    HacL_HPE1313A:0_Ch55 : 23.1445
    HacL_HPE1313A:0_Ch54 : -0.297363
    -----
    Right Arm Collimator : -0.00854492
    HacR_HPE1313A:0_Ch58 : -0.569824
    HacR_HPE1313A:0_Ch55 : 21.7285
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 151
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.82609
    SLI vert. size mm : 0
    SLI y position : 3.00469
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.25
    temperature loop 1(2) : 99.89
    temperature loop 1(3) : 95.17
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.98
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 60.3064
    -----