Run Number: 1712
End of Run Comment:
Run_type=Other,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8526,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Production LH2 6cm at 19uA
PRESCALE FACTORS:ps1=4500 ps2=16777215 ps3=300 ps4=4200 ps5=1 ps6=65535 ps7=65535 ps8=100
EVENTS : [0]: 5006597 [+]: 2464153 [-]: 2468435
TIME : [0]: 45.567 mins [+]: 22.483 mins [-]: 22.481 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -7.02760 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 37.10% [+]: 37.20% [-]: 37.24%
TRIGGER RATES: PRES/REAL
T1[0] :17.0/76279.9 Hz T2[0] : 0.0/0.0 Hz T3[0] :18.6/5583.6 Hz T4[0] : 4.5/19051.4 Hz T5[0] :2871.6/2871.6 Hz T6[0] : 0.0/0.0 Hz T7[0] : 0.0/0.0 Hz T8[0] :10.2/1024.0 Hz
T1[+] :16.9/76244.7 Hz T2[+] : 0.0/0.0 Hz T3[+] :18.6/5579.1 Hz T4[+] : 4.5/19046.8 Hz T5[+] :2868.6/2868.6 Hz T6[+] : 0.0/0.0 Hz T7[+] : 0.0/0.0 Hz T8[+] :10.2/1024.0 Hz
T1[-] :17.0/76356.8 Hz T2[-] : 0.0/0.0 Hz T3[-] :18.6/5590.6 Hz T4[-] : 4.5/19064.5 Hz T5[-] :2876.0/2876.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 46344/208551645 T2[0] : 0/0 T3[0] : 50886/15265855 T4[0] : 12401/52087272 T5[0] :7851101/7851101 T6[0] : 0/0 T7[0] : 0/0 T8[0] : 27996/2799649
T1[+] : 22856/102854678 T2[+] : 0/0 T3[+] : 25087/7526287 T4[+] : 6117/25694293 T5[+] :3869793/3869793 T6[+] : 0/0 T7[+] : 0/0 T8[+] : 13813/1381383
T1[-] : 22888/102996685 T2[-] : 0/0 T3[-] : 25137/7541145 T4[-] : 6122/25715894 T5[-] :3879460/3879460 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 13812/1381260
AVERAGE CURRENT
BCM x1 : 16.6750uA BCM x3 : 16.6746uA BCM x10: 8.3766 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -892.4 ppm BCM u3 : -856.5 ppm BCM u10: 1E+39 ppm
BCM d1 : -898.2 ppm BCM d3 : -845.6 ppm BCM d10: -851.5 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.04572 BCM u3 [0]:0.04573 BCM u10[0]:-5.075E-05
BCM u1 [+]:0.02255 BCM u3 [+]:0.02255 BCM u10[+]:-2.505E-05
BCM u1 [-]:0.02259 BCM u3 [-]:0.02259 BCM u10[-]:-2.504E-05
BCM d1 [0]:0.04546 BCM d3 [0]:0.04545 BCM d10[0]:0.04585
BCM d1 [+]:0.02241 BCM d3 [+]:0.02241 BCM d10[+]:0.02261
BCM d1 [-]:0.02245 BCM d3 [-]:0.02245 BCM d10[-]:0.02265
****************************
End-of-run EPICS data for Run Number 1712 at Fri May 30 04:39:31 EDT 2008
Wien angle : -13.5361
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.852617
Left Arm arm angle : 46.9997
Right Arm D1 momentum : 0.00433679
Right Arm arm angle : 0.197
HALLA:p : 1192.13
HALLA:dpp : -0.000214855
Tiefenbach Hall A energy : 1192.13
Left Arm Top VDC Current : 4.73633
Left Arm Bottom VDC Current : 3.95508
-----
Left Arm Q1 momentum : 0.852425
Left Arm Q1 power supply : 641.306
Left Arm Q1 gauss meter : 0.05479
Left Arm Q2 gauss meter : -0.19351
Left Arm Q2 power supply current : 367.212
Left Arm Q2 momentum : 0.852792
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 284.304
Left Arm D1 momentum : 0.852617
Left Arm D1 NMR : 0.35913
Left Arm Q3 gauss meter : 0.172865
Left Arm Q3 power supply current : 339.425
Left Arm Q3 momentum : 0.852572
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00551962
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -0.0001208
Right Arm Q2 power supply current : -0.000229238
Right Arm Q2 momentum : -5.32658e-07
Right Arm Q2 gauss meter : -0.000296
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0266452
Right Arm D1 momentum : 0.00433816
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 0
Right Arm Q3 momentum : 0.000191425
Right Arm Q3 gauss meter : -0.000266
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 700
BigBite magnet current readback : 696.603
BigBite Gaussmeter readback : 0.5629
-----
Average current of the two cavities : 19.5516
Current on Unser monitor : 33.2359
Current on Upstream bcm : 19.1528
Current on Downstream bcm : 19.9505
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 97.3076
Hall C Current : ibcm1 --- Invalid channel name
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.13
Hall A momentum orbit correction (dpp) : -0.000211907
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.13
Hall C energy (hallc_MeV) : 5710.96
Delta(E)/E width (MV_AI_DXWID) : 1.25813
IPM1C12.XPOS : 0.842738
IPM1H04A.XPOS : -1.12663
IPM1H04A.YPOS : 1.13132
IPM1H04B.XPOS : -1.79477
IPM1H04B.YPOS : 1.89666
-----
Left Arm Collimator : 0.87124
HacL_HPE1313A:0_Ch58 : -0.302246
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.297852
-----
Right Arm Collimator : -0.0081543
HacR_HPE1313A:0_Ch58 : -0.569336
HacR_HPE1313A:0_Ch55 : 21.7773
HacR_HPE1313A:0_Ch54 : -0.848633
-----
Wien angle : -13.5361
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -315.67
Wien field : 8.9165
Laser attenuation Hall A : 147
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.19255
SLI vert. size mm : 0
SLI y position : 0.510798
-----
Target : L3 6cm
fan frequency loop 1 : 0
fan frequency loop 3 : 36.5
Encoder position : 2.06493e+07
Target type : 2.06493e+07
temperature loop 1(1) : 100.26
temperature loop 1(2) : 99.89
temperature loop 1(3) : 95.33
temperature loop 3(1) : 20
temperature loop 3(2) : 19.98
temperature loop 3(3) : 29.99
Heat exchange LH2 : 90.9
Heat exchange LH2 : 20.1
HPH H2 loop 1 : 0.0970926
HPH H2 loop 3 : 59.5158
-----