Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 07:27:04 on May 30, 2008

    Entry number 240379

    keyword=End_of_Run_1715
    ****************************
     Run Number: 1715
     End of Run Comment:
    Run_type=Other,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8526,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Production LH2 6cm at 19uA
     
    
    PRESCALE FACTORS:ps1=4500   ps2=16777215   ps3=300   ps4=4200   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5006031      [+]: 2465401      [-]: 2466680      
    TIME     : [0]: 55.513 mins  [+]: 27.380 mins  [-]: 27.378 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.25856 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  36.42%      [+]:  36.50%      [-]:  36.57%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.7/61832.7 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :15.1/4536.6 Hz   T4[0] : 3.8/15793.0 Hz   T5[0] :2329.7/2329.7 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :13.7/61809.3 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :15.1/4533.7 Hz   T4[+] : 3.8/15785.6 Hz   T5[+] :2329.1/2329.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :13.8/61919.5 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :15.1/4543.9 Hz   T4[-] : 3.8/15814.6 Hz   T5[-] :2332.9/2332.9 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  45766/205949504  T2[0] :      0/0        T3[0] :  50367/15110321  T4[0] :  12524/52602532  T5[0] :7759621/7759621  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  34106/3410694  
    T1[+] :  22564/101538838  T2[+] :      0/0        T3[+] :  24826/7447891  T4[+] :   6174/25932133  T5[+] :3826172/3826172  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  16822/1682203  
    T1[-] :  22602/101713430  T2[-] :      0/0        T3[-] :  24880/7464161  T4[-] :   6185/25978113  T5[-] :3832150/3832150  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  16820/1682095  
    
    AVERAGE CURRENT
    BCM x1 : 14.9045uA  BCM x3 : 14.9023uA  BCM x10: 7.4681 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -943.8 ppm     BCM u3 :   -906.3 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :   -950.1 ppm     BCM d3 :   -893.6 ppm     BCM d10:     -896 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.04988        BCM u3 [0]:0.04988        BCM u10[0]:-6.184E-05     
    BCM u1 [+]:0.02459        BCM u3 [+]:0.02459        BCM u10[+]:-3.05E-05      
    BCM u1 [-]:0.02464        BCM u3 [-]:0.02464        BCM u10[-]:-3.05E-05      
    
    BCM d1 [0]:0.0494         BCM d3 [0]:0.04939        BCM d10[0]:0.04981        
    BCM d1 [+]:0.02436        BCM d3 [+]:0.02435        BCM d10[+]:0.02456        
    BCM d1 [-]:0.0244         BCM d3 [-]:0.02439        BCM d10[-]:0.0246         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1715 at Fri May 30 07:26:55 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.852618
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.0043556
    Right Arm arm angle : 0.197
    HALLA:p : 1192.12
    HALLA:dpp : -0.000221031
    Tiefenbach Hall A energy : 1192.12
    Left Arm Top VDC Current : 4.63867
    Left Arm Bottom VDC Current : -1.41602
    -----
    Left Arm Q1 momentum : 0.852425
    Left Arm Q1 power supply : 641.306
    Left Arm Q1 gauss meter : 0.0548
    Left Arm Q2 gauss meter : -0.19354
    Left Arm Q2 power supply current : 367.207
    Left Arm Q2 momentum : 0.85278
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 284.303
    Left Arm D1 momentum : 0.852618
    Left Arm D1 NMR : 0.35913
    Left Arm Q3 gauss meter : 0.172882
    Left Arm Q3 power supply current : 339.42
    Left Arm Q3 momentum : 0.852561
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.0047508
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001096
    Right Arm Q2 power supply current : -4.43687e-05
    Right Arm Q2 momentum : -1.03095e-07
    Right Arm Q2 gauss meter : -0.0002905
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0264722
    Right Arm D1 momentum : 0.00434933
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -8.21987e-05
    Right Arm Q3 momentum : -2.06577e-07
    Right Arm Q3 gauss meter : -0.0002656
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5634
    -----
    Average current of the two cavities : 21.5098
    Current on Unser monitor : 32.425
    Current on Upstream bcm : 21.1781
    Current on Downstream bcm : 21.8415
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 97.2852
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.12
    Hall A momentum orbit correction (dpp) : -0.000219136
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.12
    Hall C energy (hallc_MeV) : 5710.97
    Delta(E)/E width (MV_AI_DXWID) : 1.28036
    IPM1C12.XPOS : 0.874461
    IPM1H04A.XPOS : -1.13149
    IPM1H04A.YPOS : 1.12805
    IPM1H04B.XPOS : -1.8118
    IPM1H04B.YPOS : 1.89219
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.302734
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.297852
    -----
    Right Arm Collimator : -0.00869141
    HacR_HPE1313A:0_Ch58 : -0.570312
    HacR_HPE1313A:0_Ch55 : 21.7285
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 155
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.37888
    SLI vert. size mm : 0
    SLI y position : 0.555869
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.27
    temperature loop 1(2) : 99.89
    temperature loop 1(3) : 95.15
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 90.9
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 42.1067
    -----