    Entry number 240394

    keyword=End_of_Run_1721
    ****************************
     Run Number: 1721
     End of Run Comment:
    Run_type=Calibration,target_type=Al Dummy,beam_e0=1.192,beam_raster=on,leftarm_p=0.8526,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=20uA
     
    
    PRESCALE FACTORS:ps1=4500   ps2=16777215   ps3=300   ps4=4200   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 59773        [+]: 29467        [-]: 29389        
    TIME     : [0]: 17.607 mins  [+]: 8.709 mins  [-]: 8.710 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -5.37202 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   1.77%      [+]:   2.12%      [-]:   2.37%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 6.2/28030.6 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :11.0/3286.4 Hz   T4[0] : 4.3/18183.2 Hz   T5[0] :25.9/25.9 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] : 6.2/28012.9 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :10.9/3281.1 Hz   T4[+] : 4.3/18174.6 Hz   T5[+] :26.0/26.0 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] : 6.2/28071.0 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :11.0/3293.3 Hz   T4[-] : 4.3/18203.9 Hz   T5[-] :25.9/25.9 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   6580/29612869  T2[0] :      0/0        T3[0] :  11573/3471957  T4[0] :   4573/19209583  T5[0] :  27407/27407    T6[0] :      0/0        T7[0] :      0/0        T8[0] :  10818/1081803  
    T1[+] :   3252/14637488  T2[+] :      0/0        T3[+] :   5714/1714467  T4[+] :   2261/9496692  T5[+] :  13578/13578    T6[+] :      0/0        T7[+] :      0/0        T8[+] :   5350/535067   
    T1[-] :   3259/14669104  T2[-] :      0/0        T3[-] :   5736/1720966  T4[-] :   2264/9512846  T5[-] :  13542/13542    T6[-] :      0/0        T7[-] :      0/0        T8[-] :   5351/535114   
    
    AVERAGE CURRENT
    BCM x1 : 19.1650uA  BCM x3 : 19.1624uA  BCM x10: 9.6058 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1256 ppm     BCM u3 :    -1214 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1259 ppm     BCM d3 :    -1196 ppm     BCM d10:    -1204 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.02034        BCM u3 [0]:0.02034        BCM u10[0]:-1.963E-05     
    BCM u1 [+]:0.01005        BCM u3 [+]:0.01006        BCM u10[+]:-9.709E-06     
    BCM u1 [-]:0.01008        BCM u3 [-]:0.01008        BCM u10[-]:-9.711E-06     
    
    BCM d1 [0]:0.02015        BCM d3 [0]:0.02014        BCM d10[0]:0.02032        
    BCM d1 [+]:0.009958       BCM d3 [+]:0.009956       BCM d10[+]:0.01004        
    BCM d1 [-]:0.009984       BCM d3 [-]:0.00998        BCM d10[-]:0.01007        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1721 at Fri May 30 11:31:06 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.852618
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00434661
    Right Arm arm angle : 0.197
    HALLA:p : 1192.21
    HALLA:dpp : -0.000149874
    Tiefenbach Hall A energy : 1192.21
    Left Arm Top VDC Current : 3.80859
    Left Arm Bottom VDC Current : -1.9043
    -----
    Left Arm Q1 momentum : 0.852496
    Left Arm Q1 power supply : 641.306
    Left Arm Q1 gauss meter : 0.05481
    Left Arm Q2 gauss meter : -0.19355
    Left Arm Q2 power supply current : 367.206
    Left Arm Q2 momentum : 0.852778
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 284.303
    Left Arm D1 momentum : 0.852618
    Left Arm D1 NMR : 0.35913
    Left Arm Q3 gauss meter : 0.172867
    Left Arm Q3 power supply current : 339.419
    Left Arm Q3 momentum : 0.852558
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00437434
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001014
    Right Arm Q2 power supply current : -5.91583e-05
    Right Arm Q2 momentum : -5.84205e-07
    Right Arm Q2 gauss meter : -0.0003027
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0271464
    Right Arm D1 momentum : 0.00435097
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -0.000119562
    Right Arm Q3 momentum : -3.00475e-07
    Right Arm Q3 gauss meter : -0.0002657
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5634
    -----
    Average current of the two cavities : 21.4197
    Current on Unser monitor : 31.8213
    Current on Upstream bcm : 21.1971
    Current on Downstream bcm : 21.6423
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 112.382
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.19
    Hall A momentum orbit correction (dpp) : -0.000161625
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.19
    Hall C energy (hallc_MeV) : 5710.96
    Delta(E)/E width (MV_AI_DXWID) : 1.5059
    IPM1C12.XPOS : 0.657484
    IPM1H04A.XPOS : -1.14024
    IPM1H04A.YPOS : 1.1404
    IPM1H04B.XPOS : -1.81056
    IPM1H04B.YPOS : 1.91407
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.301758
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.298828
    -----
    Right Arm Collimator : -0.00849609
    HacR_HPE1313A:0_Ch58 : -0.569824
    HacR_HPE1313A:0_Ch55 : 21.7773
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 152
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.78137
    SLI vert. size mm : 0
    SLI y position : 0.923944
    -----
    Target : Dummy
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 1.32517e+07
    Target type : 1.32517e+07
    temperature loop 1(1) : 100.47
    temperature loop 1(2) : 100.09
    temperature loop 1(3) : 95.31
    temperature loop 3(1) : 19.99
    temperature loop 3(2) : 19.98
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 112.904
    -----