     Run Number: 1722
     End of Run Comment:
    Run_type=Test,target_type=Loop 1 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8359,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=test run preshower and shower on kin 6 delta 0
     
    
    PRESCALE FACTORS:ps1=4500   ps2=16777215   ps3=300   ps4=4200   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 510074       [+]: 250746       [-]: 251891       
    TIME     : [0]: 7.135 mins  [+]: 3.550 mins  [-]: 3.549 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.66327 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  22.74%      [+]:  23.52%      [-]:  23.56%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :115.5/519615.7 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 6.6/1990.1 Hz   T4[0] : 1.6/6868.2 Hz   T5[0] :1413.3/1413.3 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :115.4/519342.3 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 6.6/1988.5 Hz   T4[+] : 1.6/6859.4 Hz   T5[+] :1410.3/1410.3 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :115.7/520613.6 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 6.6/1994.6 Hz   T4[-] : 1.6/6883.4 Hz   T5[-] :1418.3/1418.3 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  49436/222462502  T2[0] :      0/0        T3[0] :   2840/852009   T4[0] :    700/2940476  T5[0] : 605070/605070   T6[0] :      0/0        T7[0] :      0/0        T8[0] :   4384/438404   
    T1[+] :  24585/110633101  T2[+] :      0/0        T3[+] :   1412/423608   T4[+] :    347/1461225  T5[+] : 300420/300420   T6[+] :      0/0        T7[+] :      0/0        T8[+] :   2181/218138   
    T1[-] :  24636/110865275  T2[-] :      0/0        T3[-] :   1415/424761   T4[-] :    349/1465824  T5[-] : 302034/302034   T6[-] :      0/0        T7[-] :      0/0        T8[-] :   2180/218062   
    
    AVERAGE CURRENT
    BCM x1 : 4.8960 uA  BCM x3 : 4.8972 uA  BCM x10: 2.4518 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1422 ppm     BCM u3 :    -1339 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1451 ppm     BCM d3 :    -1316 ppm     BCM d10:    -1318 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.002107       BCM u3 [0]:0.002106       BCM u10[0]:-7.949E-06     
    BCM u1 [+]:0.001048       BCM u3 [+]:0.001047       BCM u10[+]:-3.956E-06     
    BCM u1 [-]:0.00105        BCM u3 [-]:0.00105        BCM u10[-]:-3.953E-06     
    
    BCM d1 [0]:0.002085       BCM d3 [0]:0.002087       BCM d10[0]:0.002107       
    BCM d1 [+]:0.001037       BCM d3 [+]:0.001038       BCM d10[+]:0.001048       
    BCM d1 [-]:0.001039       BCM d3 [-]:0.00104        BCM d10[-]:0.00105        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1722 at Fri May 30 11:50:54 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.835877
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00440193
    Right Arm arm angle : 0.197
    HALLA:p : 1192.22
    HALLA:dpp : -0.000141533
    Tiefenbach Hall A energy : 1192.22
    Left Arm Top VDC Current : 0.976562
    Left Arm Bottom VDC Current : -0.195312
    -----
    Left Arm Q1 momentum : 0.835885
    Left Arm Q1 power supply : 628.862
    Left Arm Q1 gauss meter : 0.05375
    Left Arm Q2 gauss meter : -0.18964
    Left Arm Q2 power supply current : 359.883
    Left Arm Q2 momentum : 0.835772
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 278.662
    Left Arm D1 momentum : 0.835877
    Left Arm D1 NMR : 0.352074
    Left Arm Q3 gauss meter : 0.169559
    Left Arm Q3 power supply current : 332.812
    Left Arm Q3 momentum : 0.835961
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00342524
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -8.46e-05
    Right Arm Q2 power supply current : -0.000221844
    Right Arm Q2 momentum : -3.60833e-07
    Right Arm Q2 gauss meter : -0.0003033
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.02745
    Right Arm D1 momentum : 0.00440193
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000145716
    Right Arm Q3 momentum : 0.000190865
    Right Arm Q3 gauss meter : -0.0002659
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5636
    -----
    Average current of the two cavities : 5.27026
    Current on Unser monitor : 16.6877
    Current on Upstream bcm : 5.17583
    Current on Downstream bcm : 5.36469
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 97.2852
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.22
    Hall A momentum orbit correction (dpp) : -0.000142387
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.21
    Hall C energy (hallc_MeV) : 5710.98
    Delta(E)/E width (MV_AI_DXWID) : 1.4371
    IPM1C12.XPOS : 0.540218
    IPM1H04A.XPOS : -1.12366
    IPM1H04A.YPOS : 1.20933
    IPM1H04B.XPOS : -1.78063
    IPM1H04B.YPOS : 1.95889
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.302246
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.300293
    -----
    Right Arm Collimator : -0.00878906
    HacR_HPE1313A:0_Ch58 : -0.569336
    HacR_HPE1313A:0_Ch55 : 21.7773
    HacR_HPE1313A:0_Ch54 : -0.847656
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 97
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.23602
    SLI vert. size mm : 0
    SLI y position : 0.510798
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.52
    temperature loop 1(2) : 100.14
    temperature loop 1(3) : 95.47
    temperature loop 3(1) : 19.99
    temperature loop 3(2) : 19.98
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.132774
    HPH H2 loop 3 : 124.588
    -----