Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 12:41:37 on May 30, 2008

    Entry number 240414

    keyword=End_of_Run_1724
    ****************************
     Run Number: 1724
     End of Run Comment:
    Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8359,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=5000   ps2=16777215   ps3=400   ps4=5000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5007306      [+]: 2465352      [-]: 2468072      
    TIME     : [0]: 40.918 mins  [+]: 20.191 mins  [-]: 20.190 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -6.56366 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  41.98%      [+]:  42.04%      [-]:  42.16%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :17.3/86439.9 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :16.2/6475.9 Hz   T4[0] : 3.8/18860.8 Hz   T5[0] :3477.7/3477.7 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :17.3/86370.3 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :16.2/6467.5 Hz   T4[+] : 3.8/18840.5 Hz   T5[+] :3473.3/3473.3 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :17.3/86560.0 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :16.2/6488.6 Hz   T4[-] : 3.8/18892.2 Hz   T5[-] :3484.4/3484.4 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42443/212215838  T2[0] :      0/0        T3[0] :  39746/15898779  T4[0] :   9260/46304628  T5[0] :8537980/8537980  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  25139/2513990  
    T1[+] :  20926/104632648  T2[+] :      0/0        T3[+] :  19587/7835008  T4[+] :   4564/22824215  T5[+] :4207712/4207712  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  12405/1240517  
    T1[-] :  20972/104860856  T2[-] :      0/0        T3[-] :  19650/7860392  T4[-] :   4577/22886480  T5[-] :4221130/4221130  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  12404/1240498  
    
    AVERAGE CURRENT
    BCM x1 : 16.3531uA  BCM x3 : 16.3517uA  BCM x10: 8.2006 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1266 ppm     BCM u3 :    -1222 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1269 ppm     BCM d3 :    -1206 ppm     BCM d10:    -1217 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.04034        BCM u3 [0]:0.04034        BCM u10[0]:-4.561E-05     
    BCM u1 [+]:0.01988        BCM u3 [+]:0.01989        BCM u10[+]:-2.251E-05     
    BCM u1 [-]:0.01993        BCM u3 [-]:0.01993        BCM u10[-]:-2.251E-05     
    
    BCM d1 [0]:0.03996        BCM d3 [0]:0.03995        BCM d10[0]:0.04031        
    BCM d1 [+]:0.0197         BCM d3 [+]:0.0197         BCM d10[+]:0.01987        
    BCM d1 [-]:0.01975        BCM d3 [-]:0.01974        BCM d10[-]:0.01992        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1724 at Fri May 30 12:41:27 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.835877
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00436759
    Right Arm arm angle : 0.197
    HALLA:p : 1192.33
    HALLA:dpp : -4.79517e-05
    Tiefenbach Hall A energy : 1192.33
    Left Arm Top VDC Current : 0.390625
    Left Arm Bottom VDC Current : -1.2207
    -----
    Left Arm Q1 momentum : 0.835885
    Left Arm Q1 power supply : 628.862
    Left Arm Q1 gauss meter : 0.05376
    Left Arm Q2 gauss meter : -0.18966
    Left Arm Q2 power supply current : 359.882
    Left Arm Q2 momentum : 0.835769
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 278.661
    Left Arm D1 momentum : 0.835877
    Left Arm D1 NMR : 0.352074
    Left Arm Q3 gauss meter : 0.169558
    Left Arm Q3 power supply current : 332.811
    Left Arm Q3 momentum : 0.835959
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00528632
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001197
    Right Arm Q2 power supply current : -3.32765e-05
    Right Arm Q2 momentum : -3.60833e-07
    Right Arm Q2 gauss meter : -0.0002963
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0240294
    Right Arm D1 momentum : 0.00436759
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -3.7363e-06
    Right Arm Q3 momentum : -9.38985e-09
    Right Arm Q3 gauss meter : -0.0002657
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5634
    -----
    Average current of the two cavities : 19.363
    Current on Unser monitor : 31.3561
    Current on Upstream bcm : 19.0373
    Current on Downstream bcm : 19.6887
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 110.649
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.32
    Hall A momentum orbit correction (dpp) : -5.19568e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.32
    Hall C energy (hallc_MeV) : 5710.93
    Delta(E)/E width (MV_AI_DXWID) : 1.50008
    IPM1C12.XPOS : 0.20218
    IPM1H04A.XPOS : -1.13203
    IPM1H04A.YPOS : 1.12372
    IPM1H04B.XPOS : -1.80196
    IPM1H04B.YPOS : 1.88604
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.301758
    HacL_HPE1313A:0_Ch55 : 23.1445
    HacL_HPE1313A:0_Ch54 : -0.299805
    -----
    Right Arm Collimator : -0.00830078
    HacR_HPE1313A:0_Ch58 : -0.569336
    HacR_HPE1313A:0_Ch55 : 21.7773
    HacR_HPE1313A:0_Ch54 : -0.847656
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 147
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.879503
    SLI vert. size mm : 0
    SLI y position : 0.465728
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.35
    temperature loop 1(2) : 99.97
    temperature loop 1(3) : 95.12
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 90.8
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.152704
    HPH H2 loop 3 : 78.1136
    -----