Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 13:22:03 on May 30, 2008

    Entry number 240416

    keyword=End_of_Run_1725
    ****************************
     Run Number: 1725
     End of Run Comment:
    Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8359,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=5000   ps2=16777215   ps3=400   ps4=5000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5009015      [+]: 2465105      [-]: 2469726      
    TIME     : [0]: 39.831 mins  [+]: 19.669 mins  [-]: 19.666 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.98023 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  41.63%      [+]:  41.76%      [-]:  41.82%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :17.6/88082.6 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :16.5/6612.9 Hz   T4[0] : 3.9/19315.1 Hz   T5[0] :3552.6/3552.6 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :17.6/87989.2 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :16.5/6604.8 Hz   T4[+] : 3.9/19297.1 Hz   T5[+] :3548.4/3548.4 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :17.6/88240.3 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :16.6/6625.7 Hz   T4[-] : 3.9/19344.9 Hz   T5[-] :3559.2/3559.2 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42101/210506509  T2[0] :      0/0        T3[0] :  39510/15804042  T4[0] :   9232/46160772  T5[0] :8490273/8490273  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  24472/2447234  
    T1[+] :  20767/103837962  T2[+] :      0/0        T3[+] :  19486/7794417  T4[+] :   4554/22772933  T5[+] :4187583/4187583  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  12084/1208444  
    T1[-] :  20824/104121308  T2[-] :      0/0        T3[-] :  19545/7818180  T4[-] :   4565/22826511  T5[-] :4199733/4199733  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  12082/1208294  
    
    AVERAGE CURRENT
    BCM x1 : 16.6949uA  BCM x3 : 16.6935uA  BCM x10: 8.3726 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1411 ppm     BCM u3 :    -1366 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1419 ppm     BCM d3 :    -1349 ppm     BCM d10:    -1363 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.04008        BCM u3 [0]:0.04009        BCM u10[0]:-4.437E-05     
    BCM u1 [+]:0.01977        BCM u3 [+]:0.01977        BCM u10[+]:-2.191E-05     
    BCM u1 [-]:0.01983        BCM u3 [-]:0.01983        BCM u10[-]:-2.191E-05     
    
    BCM d1 [0]:0.03971        BCM d3 [0]:0.03971        BCM d10[0]:0.04006        
    BCM d1 [+]:0.01959        BCM d3 [+]:0.01959        BCM d10[+]:0.01976        
    BCM d1 [-]:0.01964        BCM d3 [-]:0.01964        BCM d10[-]:0.01982        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1725 at Fri May 30 13:21:53 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.835877
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00439048
    Right Arm arm angle : 0.197
    HALLA:p : 1192.31
    HALLA:dpp : -6.17546e-05
    Tiefenbach Hall A energy : 1192.31
    Left Arm Top VDC Current : 0.927734
    Left Arm Bottom VDC Current : 0.976562
    -----
    Left Arm Q1 momentum : 0.835885
    Left Arm Q1 power supply : 628.862
    Left Arm Q1 gauss meter : 0.05375
    Left Arm Q2 gauss meter : -0.18964
    Left Arm Q2 power supply current : 359.885
    Left Arm Q2 momentum : 0.835775
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 278.66
    Left Arm D1 momentum : 0.835877
    Left Arm D1 NMR : 0.352074
    Left Arm Q3 gauss meter : 0.169559
    Left Arm Q3 power supply current : 332.813
    Left Arm Q3 momentum : 0.835964
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.0042842
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001008
    Right Arm Q2 power supply current : -0.000118317
    Right Arm Q2 momentum : -2.7492e-07
    Right Arm Q2 gauss meter : -0.0003021
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0261651
    Right Arm D1 momentum : 0.00439375
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -3.36267e-05
    Right Arm Q3 momentum : -8.45087e-08
    Right Arm Q3 gauss meter : -0.000266
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5633
    -----
    Average current of the two cavities : 19.3118
    Current on Unser monitor : 31.4545
    Current on Upstream bcm : 19.2082
    Current on Downstream bcm : 19.4153
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 110.471
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.31
    Hall A momentum orbit correction (dpp) : -5.92103e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.31
    Hall C energy (hallc_MeV) : 5710.93
    Delta(E)/E width (MV_AI_DXWID) : 1.4146
    IPM1C12.XPOS : 0.243544
    IPM1H04A.XPOS : -1.12193
    IPM1H04A.YPOS : 1.15186
    IPM1H04B.XPOS : -1.79541
    IPM1H04B.YPOS : 1.92553
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.301758
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.300293
    -----
    Right Arm Collimator : -0.00854492
    HacR_HPE1313A:0_Ch58 : -0.568848
    HacR_HPE1313A:0_Ch55 : 21.7285
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 147
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.790062
    SLI vert. size mm : 0
    SLI y position : 3.36526
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.22
    temperature loop 1(2) : 99.85
    temperature loop 1(3) : 94.9
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 90.7
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0669839
    HPH H2 loop 3 : 85.0308
    -----