    keyword=End_of_Run_1726
    ****************************
     Run Number: 1726
     End of Run Comment:
    Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8359,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=5000   ps2=16777215   ps3=400   ps4=5000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5009251      [+]: 2465770      [-]: 2469613      
    TIME     : [0]: 39.261 mins  [+]: 19.376 mins  [-]: 19.374 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -6.51444 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  41.95%      [+]:  42.04%      [-]:  42.10%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :18.0/89853.2 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :16.9/6748.1 Hz   T4[0] : 3.9/19661.7 Hz   T5[0] :3624.4/3624.4 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :18.0/89757.9 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :16.9/6740.8 Hz   T4[+] : 3.9/19647.8 Hz   T5[+] :3620.3/3620.3 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :18.0/89991.1 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :16.9/6759.6 Hz   T4[-] : 3.9/19685.7 Hz   T5[-] :3630.7/3630.7 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42333/211665599  T2[0] :      0/0        T3[0] :  39741/15896447  T4[0] :   9263/46316809  T5[0] :8537889/8537889  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  24122/2412218  
    T1[+] :  20869/104348816  T2[+] :      0/0        T3[+] :  19591/7836535  T4[+] :   4568/22841700  T5[+] :4208786/4208786  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  11904/1190460  
    T1[-] :  20921/104609006  T2[-] :      0/0        T3[-] :  19643/7857595  T4[-] :   4576/22883372  T5[-] :4220451/4220451  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  11903/1190336  
    
    AVERAGE CURRENT
    BCM x1 : 17.0039uA  BCM x3 : 17.0026uA  BCM x10: 8.5276 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1266 ppm     BCM u3 :    -1227 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1273 ppm     BCM d3 :    -1210 ppm     BCM d10:    -1222 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.04024        BCM u3 [0]:0.04025        BCM u10[0]:-4.375E-05     
    BCM u1 [+]:0.01984        BCM u3 [+]:0.01984        BCM u10[+]:-2.159E-05     
    BCM u1 [-]:0.01989        BCM u3 [-]:0.01989        BCM u10[-]:-2.159E-05     
    
    BCM d1 [0]:0.03987        BCM d3 [0]:0.03986        BCM d10[0]:0.04022        
    BCM d1 [+]:0.01966        BCM d3 [+]:0.01965        BCM d10[+]:0.01983        
    BCM d1 [-]:0.0197         BCM d3 [-]:0.0197         BCM d10[-]:0.01988        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1726 at Fri May 30 14:01:39 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.835877
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00433788
    Right Arm arm angle : 0.197
    HALLA:p : 1192.31
    HALLA:dpp : -6.38626e-05
    Tiefenbach Hall A energy : 1192.31
    Left Arm Top VDC Current : 2.05078
    Left Arm Bottom VDC Current : 2.09961
    -----
    Left Arm Q1 momentum : 0.835885
    Left Arm Q1 power supply : 628.862
    Left Arm Q1 gauss meter : 0.05376
    Left Arm Q2 gauss meter : -0.1897
    Left Arm Q2 power supply current : 359.882
    Left Arm Q2 momentum : 0.835769
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 278.66
    Left Arm D1 momentum : 0.835877
    Left Arm D1 NMR : 0.352074
    Left Arm Q3 gauss meter : 0.169553
    Left Arm Q3 power supply current : 332.81
    Left Arm Q3 momentum : 0.835956
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00527041
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001194
    Right Arm Q2 power supply current : -0.000207054
    Right Arm Q2 momentum : -4.8111e-07
    Right Arm Q2 gauss meter : -0.0002927
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0278313
    Right Arm D1 momentum : 0.00433162
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000127034
    Right Arm Q3 momentum : 0.000191985
    Right Arm Q3 gauss meter : -0.0002658
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5636
    -----
    Average current of the two cavities : 19.1831
    Current on Unser monitor : 30.2096
    Current on Upstream bcm : 18.8484
    Current on Downstream bcm : 19.5178
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 109.9
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.31
    Hall A momentum orbit correction (dpp) : -6.57118e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.31
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 1.46288
    IPM1C12.XPOS : 0.253393
    IPM1H04A.XPOS : -1.1431
    IPM1H04A.YPOS : 1.12367
    IPM1H04B.XPOS : -1.81858
    IPM1H04B.YPOS : 1.88935
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.30127
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.299316
    -----
    Right Arm Collimator : -0.00834961
    HacR_HPE1313A:0_Ch58 : -0.569824
    HacR_HPE1313A:0_Ch55 : 21.7773
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 148
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.491925
    SLI vert. size mm : 0
    SLI y position : 3.13239
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 35.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.18
    temperature loop 1(2) : 99.81
    temperature loop 1(3) : 94.8
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 90.7
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0540192
    HPH H2 loop 3 : 48.6385
    -----