    Log entry time 14:41:29 on May 30, 2008

    Entry number 240422

    keyword=End_of_Run_1727
    ****************************
     Run Number: 1727
     End of Run Comment:
    Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8359,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=5000   ps2=16777215   ps3=400   ps4=5000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5002303      [+]: 2462924      [-]: 2465656      
    TIME     : [0]: 39.101 mins  [+]: 19.302 mins  [-]: 19.300 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.05428 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  41.86%      [+]:  41.92%      [-]:  42.05%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :18.0/90004.9 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :16.9/6758.5 Hz   T4[0] : 3.9/19716.2 Hz   T5[0] :3628.6/3628.6 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :18.0/89897.9 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :16.9/6748.7 Hz   T4[+] : 3.9/19694.0 Hz   T5[+] :3623.0/3623.0 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :18.0/90151.7 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :16.9/6770.8 Hz   T4[-] : 3.9/19745.5 Hz   T5[-] :3635.5/3635.5 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42231/211159076  T2[0] :      0/0        T3[0] :  39639/15855969  T4[0] :   9251/46255875  T5[0] :8512914/8512914  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  24023/2402389  
    T1[+] :  20822/104110994  T2[+] :      0/0        T3[+] :  19539/7815650  T4[+] :   4561/22807672  T5[+] :4195842/4195842  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  11858/1185897  
    T1[-] :  20878/104393609  T2[-] :      0/0        T3[-] :  19601/7840452  T4[-] :   4572/22864857  T5[-] :4209878/4209878  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  11857/1185769  
    
    AVERAGE CURRENT
    BCM x1 : 16.9041uA  BCM x3 : 16.9031uA  BCM x10: 8.4791 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1433 ppm     BCM u3 :    -1388 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1440 ppm     BCM d3 :    -1367 ppm     BCM d10:    -1383 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.03984        BCM u3 [0]:0.03984        BCM u10[0]:-4.357E-05     
    BCM u1 [+]:0.01964        BCM u3 [+]:0.01964        BCM u10[+]:-2.151E-05     
    BCM u1 [-]:0.01969        BCM u3 [-]:0.01969        BCM u10[-]:-2.15E-05      
    
    BCM d1 [0]:0.03948        BCM d3 [0]:0.03947        BCM d10[0]:0.03983        
    BCM d1 [+]:0.01946        BCM d3 [+]:0.01946        BCM d10[+]:0.01964        
    BCM d1 [-]:0.01952        BCM d3 [-]:0.01951        BCM d10[-]:0.01969        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1727 at Fri May 30 14:41:18 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.835876
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00440465
    Right Arm arm angle : 0.197
    HALLA:p : 1192.31
    HALLA:dpp : -6.29667e-05
    Tiefenbach Hall A energy : 1192.31
    Left Arm Top VDC Current : 4.00391
    Left Arm Bottom VDC Current : -1.02539
    -----
    Left Arm Q1 momentum : 0.835885
    Left Arm Q1 power supply : 628.862
    Left Arm Q1 gauss meter : 0.05377
    Left Arm Q2 gauss meter : -0.18968
    Left Arm Q2 power supply current : 359.882
    Left Arm Q2 momentum : 0.83577
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 278.658
    Left Arm D1 momentum : 0.835876
    Left Arm D1 NMR : 0.352074
    Left Arm Q3 gauss meter : 0.169546
    Left Arm Q3 power supply current : 332.812
    Left Arm Q3 momentum : 0.835961
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00349947
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -8.6e-05
    Right Arm Q2 power supply current : 4.43687e-05
    Right Arm Q2 momentum : 0.00121895
    Right Arm Q2 gauss meter : -0.0002958
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0267158
    Right Arm D1 momentum : 0.00439839
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -0.00010088
    Right Arm Q3 momentum : -2.53526e-07
    Right Arm Q3 gauss meter : -0.0002658
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5636
    -----
    Average current of the two cavities : 17.4057
    Current on Unser monitor : 30.1652
    Current on Upstream bcm : 17.0165
    Current on Downstream bcm : 17.7949
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 110.305
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.3
    Hall A momentum orbit correction (dpp) : -6.81993e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.3
    Hall C energy (hallc_MeV) : 5710.97
    Delta(E)/E width (MV_AI_DXWID) : 1.44219
    IPM1C12.XPOS : 0.267262
    IPM1H04A.XPOS : -1.11962
    IPM1H04A.YPOS : 1.13093
    IPM1H04B.XPOS : -1.79275
    IPM1H04B.YPOS : 1.89594
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.30127
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.299805
    -----
    Right Arm Collimator : -0.00810547
    HacR_HPE1313A:0_Ch58 : -0.569336
    HacR_HPE1313A:0_Ch55 : 21.7773
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 147
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.49068
    SLI vert. size mm : 0
    SLI y position : 2.42629
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.25
    temperature loop 1(2) : 99.88
    temperature loop 1(3) : 94.99
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.98
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 90.8
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.196744
    HPH H2 loop 3 : 68.0771
    -----