Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 15:24:11 on May 30, 2008

    Entry number 240424

    keyword=End_of_Run_1728
    ****************************
     Run Number: 1728
     End of Run Comment:
    Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8359,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=5000   ps2=16777215   ps3=400   ps4=5000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5003460      [+]: 2460835      [-]: 2468764      
    TIME     : [0]: 42.224 mins  [+]: 20.839 mins  [-]: 20.836 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.08373 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  41.64%      [+]:  41.79%      [-]:  41.75%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :16.6/82911.9 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :15.6/6239.6 Hz   T4[0] : 3.7/18356.8 Hz   T5[0] :3347.4/3347.4 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :16.6/82819.0 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :15.6/6230.6 Hz   T4[+] : 3.7/18342.7 Hz   T5[+] :3344.1/3344.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :16.6/83066.6 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :15.6/6253.1 Hz   T4[-] : 3.7/18381.6 Hz   T5[-] :3353.1/3353.1 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42010/210053930  T2[0] :      0/0        T3[0] :  39519/15807793  T4[0] :   9301/46506204  T5[0] :8480397/8480397  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  25942/2594261  
    T1[+] :  20710/103552404  T2[+] :      0/0        T3[+] :  19476/7790466  T4[+] :   4586/22934766  T5[+] :4181308/4181308  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  12803/1280354  
    T1[-] :  20769/103848786  T2[-] :      0/0        T3[-] :  19543/7817516  T4[-] :   4596/22980467  T5[-] :4191964/4191964  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  12801/1280192  
    
    AVERAGE CURRENT
    BCM x1 : 14.5233uA  BCM x3 : 14.5226uA  BCM x10: 7.2934 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1486 ppm     BCM u3 :    -1438 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1492 ppm     BCM d3 :    -1420 ppm     BCM d10:    -1433 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.03692        BCM u3 [0]:0.03692        BCM u10[0]:-4.702E-05     
    BCM u1 [+]:0.0182         BCM u3 [+]:0.0182         BCM u10[+]:-2.321E-05     
    BCM u1 [-]:0.01825        BCM u3 [-]:0.01825        BCM u10[-]:-2.32E-05      
    
    BCM d1 [0]:0.03667        BCM d3 [0]:0.03667        BCM d10[0]:0.037          
    BCM d1 [+]:0.01808        BCM d3 [+]:0.01808        BCM d10[+]:0.01824        
    BCM d1 [-]:0.01813        BCM d3 [-]:0.01812        BCM d10[-]:0.01829        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1728 at Fri May 30 15:24:01 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.835877
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00436841
    Right Arm arm angle : 0.197
    HALLA:p : 1192.3
    HALLA:dpp : -6.74979e-05
    Tiefenbach Hall A energy : 1192.3
    Left Arm Top VDC Current : 0.585938
    Left Arm Bottom VDC Current : 2.05078
    -----
    Left Arm Q1 momentum : 0.835885
    Left Arm Q1 power supply : 628.862
    Left Arm Q1 gauss meter : 0.05376
    Left Arm Q2 gauss meter : -0.1897
    Left Arm Q2 power supply current : 359.881
    Left Arm Q2 momentum : 0.835767
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 278.661
    Left Arm D1 momentum : 0.835877
    Left Arm D1 NMR : 0.352074
    Left Arm Q3 gauss meter : 0.169552
    Left Arm Q3 power supply current : 332.809
    Left Arm Q3 momentum : 0.835954
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00555673
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001248
    Right Arm Q2 power supply current : -0.000144198
    Right Arm Q2 momentum : -3.35059e-07
    Right Arm Q2 gauss meter : -0.0003029
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0278101
    Right Arm D1 momentum : 0.00434361
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 7.84624e-05
    Right Arm Q3 momentum : 0.000191985
    Right Arm Q3 gauss meter : -0.0002658
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5635
    -----
    Average current of the two cavities : 17.5297
    Current on Unser monitor : 29.4352
    Current on Upstream bcm : 17.2858
    Current on Downstream bcm : 17.7735
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 109.938
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.31
    Hall A momentum orbit correction (dpp) : -6.39338e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.31
    Hall C energy (hallc_MeV) : 5710.96
    Delta(E)/E width (MV_AI_DXWID) : 1.42118
    IPM1C12.XPOS : 0.268585
    IPM1H04A.XPOS : -1.12466
    IPM1H04A.YPOS : 1.12216
    IPM1H04B.XPOS : -1.79845
    IPM1H04B.YPOS : 1.88286
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.302246
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.300293
    -----
    Right Arm Collimator : -0.00849609
    HacR_HPE1313A:0_Ch58 : -0.569336
    HacR_HPE1313A:0_Ch55 : 21.8262
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 149
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.559006
    SLI vert. size mm : 0
    SLI y position : 1.84789
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.33
    temperature loop 1(2) : 99.95
    temperature loop 1(3) : 95.49
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 90.9
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.174027
    HPH H2 loop 3 : 60.3064
    -----