    keyword=Start_Run_1730,Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8359,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
    Run Timestamp:       Fri May 30 16:04:54 EDT 2008
    Beginning-of-run EPICS data for Run Number 1730 at Fri May 30 16:04:58 EDT 2008
    
    
    
    Run_type=Production
    target_type=Loop 1 LH2 6 cm
    beam_e0=1.192
    beam_raster=on
    leftarm_p=0.8359
    leftarm_theta=47
    leftarm_colli=out
    bbarm_i=700
    bbarm_theta=45.0
    bbarm_zoff=
    fppdoor_0p75=closed
    fppdoor_1p5=open
    fppdoor_3=closed
    fppdoor_6=open
    fppdoor_9=open
    comment_text=
    
    
    ; BBite+HRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = BigBite Calorimeter
    ; T2 = undefined
    ; T3 = L-HRS Singles (S1.and.S2)
    ; T4 = L-HRS Efficiency (S1.or.S2)
    ; T5 = T1.AND.T3 (BigBite LHRS Coincidence)
    ; T6 = undefined
    ; T7 = BigBite Cosmics
    ; T8 = 1024 Hz pulser (Note: the CRL code puts ps8 to 100 if ps8>100 here !!)
    ; String should be one line, no spaces, ending in carriage return
    ps1=5000,ps2=16777215,ps3=400,ps4=5000,ps5=1,ps6=65535,ps7=65535,ps8=100
    
    
    
    
    
    
    Left Arm Q1 momentum : 0.835885
    Left Arm Q1 power supply : 628.862
    Left Arm Q1 gauss meter : 0.05376
    Left Arm Q2 power supply current : 359.881
    Left Arm Q2 momentum : 0.835766
    Left Arm Q2 gauss meter : -0.18966
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 278.657
    Left Arm D1 momentum : 0.835876
    Left Arm D1 NMR : 0.352074
    Left Arm Q3 power supply current : 332.809
    Left Arm Q3 momentum : 0.835954
    Left Arm Q3 gauss meter : 0.169533
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : 0.2993
    -----
    Right Arm Q1 momentum : 0.00478261
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001013
    Right Arm Q2 power supply current : -0.000902164
    Right Arm Q2 momentum : -2.09627e-06
    Right Arm Q2 gauss meter : -0.0003011
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.028735
    Right Arm D1 momentum : 0.00434088
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 7.09898e-05
    Right Arm Q3 momentum : 0.000190865
    Right Arm Q3 gauss meter : -0.0002659
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : -0.0015928
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.5635
    -----
    Left Arm Top VDC Current : 0.878906
    Left Arm Bottom VDC Current : 3.85742
    Left Arm Top VDC voltage : 3.99414
    Left Arm Bottom VDC voltage : 4.00049
    -----
    Right Arm Top VDC Current : -1.12305
    Right Arm Bottom VDC Current : -1.12305
    Right Arm Top VDC voltage : -0.0107422
    Right Arm Bottom VDC voltage : 0
    -----
    Average current of the two cavities : 17.4435
    Current on Unser monitor : 30.5096
    Current on Upstream bcm : 17.1675
    Current on Downstream bcm : 17.7195
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 108.093
    Hall C Current : ibcm1 --- Invalid channel name
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.29
    Hall A momentum orbit correction (dpp) : -7.89075e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.29
    Hall C energy (hallc_MeV) : 5710.92
    Delta(E)/E width (MV_AI_DXWID) : 1.43875
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 1.5
    Raster Y width : 1.5
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.30127
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : -0.299316
    Left Arm Angle Floor Angle : 47
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 46.9997
    -----
    Right Arm Arm Collimator : -0.00864258
    HacR_HPE1313A:0_Ch58 : -0.568848
    HacR_HPE1313A:0_Ch55 : 21.7773
    HacR_HPE1313A:0_Ch54 : -0.848145
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    -----
    IPM1C12.XPOS : 0.282691
    IPM1C12.YPOS : 0.19915
    IPM1H04A.XPOS : -1.11642
    IPM1H04A.YPOS : 1.20672
    IPM1H04B.XPOS : -1.78876
    IPM1H04B.YPOS : 1.99262
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 8.9165
    Laser attenuation Hall A : 148
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 2 : 0
    fan frequency loop 3 : 35.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.41
    temperature loop 1(2) : 100.03
    temperature loop 1(3) : 95.45
    Heat exchange loop 1 H2 : 91
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange loop 3 H2 : 20
    pressure loop He : 44.0291
    pressure loop H2 before : 32.0073
    pressure loop H2 return : 32.4132
    HPH He loop 1 : 0.152704
    HPH H2 loop 3 : 57.5622
    ----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.0882
    SLI vert. size mm : 0
    SLI y position : 1.17934
    -----
    FPP High Voltages and Currents at Fri May 30 16:05:09 EDT 2008
    MF7b1469_7gn0gen.F            1848.7
    MF7b1469_7gn0gen.E            1.2
    MF7b1469_7gn0ch0property.F    1848.7
    MF7b1469_7gn0ch0property.E    0.02
    MF7b1469_7gn0ch1property.F    1848.7
    MF7b1469_7gn0ch1property.E    0.17
    MF7b1469_7gn0ch2property.F    1848.7
    MF7b1469_7gn0ch2property.E    0.06
    MF7b1469_7gn0ch3property.F    1848.7
    MF7b1469_7gn0ch3property.E    0.11
    MF7b1469_7gn0ch4property.F    1848.7
    MF7b1469_7gn0ch4property.E    0.11
    MF7b1469_7gn1gen.F            1849.9
    MF7b1469_7gn1gen.E            0.7
    MF7b1469_7gn1ch0property.F    1849.9
    MF7b1469_7gn1ch0property.E    0.06
    MF7b1469_7gn1ch1property.F    1849.9
    MF7b1469_7gn1ch1property.E    0.12
    MF7b1469_7gn1ch2property.F    1849.9
    MF7b1469_7gn1ch2property.E    0.06
    MF7b1469_7gn1ch3property.F    1849.9
    MF7b1469_7gn1ch3property.E    0.09
    MF7b1469_7gn1ch4property.F    1849.9
    MF7b1469_7gn1ch4property.E    0.13
    MF7b1469_8gn0gen.F            1850.3
    MF7b1469_8gn0gen.E            0.8
    MF7b1469_8gn0ch0property.F    1850.3
    MF7b1469_8gn0ch0property.E    0.1
    MF7b1469_8gn0ch1property.F    1850.3
    MF7b1469_8gn0ch1property.E    0.05
    MF7b1469_8gn0ch2property.F    1850.3
    MF7b1469_8gn0ch2property.E    0.1
    MF7b1469_8gn0ch3property.F    1850.3
    MF7b1469_8gn0ch3property.E    0.09
    MF7b1469_8gn0ch4property.F    1850.3
    MF7b1469_8gn0ch4property.E    0.08
    MF7b1469_8gn1gen.F            1849.8
    MF7b1469_8gn1gen.E            1.4
    MF7b1469_8gn1ch0property.F    1849.8
    MF7b1469_8gn1ch0property.E    0.06
    MF7b1469_8gn1ch1property.F    1849.8
    MF7b1469_8gn1ch1property.E    0.24
    MF7b1469_8gn1ch2property.F    1849.8
    MF7b1469_8gn1ch2property.E    0.05
    MF7b1469_8gn1ch3property.F    1849.8
    MF7b1469_8gn1ch3property.E    0.07
    MF7b1469_8gn1ch4property.F    1849.8
    MF7b1469_8gn1ch4property.E    0.32
    MF7b1469_8gn2gen.F            23.4
    MF7b1469_8gn2gen.E            0
    MF7b1469_8gn2ch0property.F    0
    MF7b1469_8gn2ch0property.E    0
    
    FPP Chamber Threshold voltages at Fri May 30 16:05:12 EDT 2008
    HrsH_FPP_TH1                  3.89648
    HrsH_FPP_TH2                  4.02783
    HrsH_FPP_TH3                  6.96631
    HrsH_FPP_TH4                  7.06689
    
    FPP Wire Chambers Low Voltage at Fri May 30 16:05:13 EDT 2008
    HrsH_FPP_LV11P                4.91943
    HrsH_FPP_LV11M                -5.30469
    HrsH_FPP_LV12MA               -5.28174
    HrsH_FPP_LV12MB               -5.58545
    HrsH_FPP_LV21P                5.08301
    HrsH_FPP_LV21M                -4.54785
    HrsH_FPP_LV22MA               -4.71631
    HrsH_FPP_LV22MB               -4.74463
    HrsH_FPP_LV31P                4.80469
    HrsH_FPP_LV31M                -5.10156
    HrsH_FPP_LV32MA               -5.08252
    HrsH_FPP_LV32MB               -4.95166
    HrsH_FPP_LV42P                4.72266
    HrsH_FPP_LV42MA               -4.73145
    HrsH_FPP_LV42MB               -4.604
    HrsH_FPP_LV41P                4.64551
    HrsH_FPP_LV41MA               -4.80518
    HrsH_FPP_LV41MB               -4.66406
    
    FPP Level Shifters at Fri May 30 16:05:14 EDT 2008
    HacH_DTC_HPE1313A:0_Ch48      5.07129
    HacH_DTC_HPE1313A:0_Ch50      -5.11377
    
    FPP Gas Flow at Fri May 30 16:05:14 EDT 2008
    HrsH_GAS_rFPPc1               5.46422
    HrsH_GAS_rFPPc2               3.47434
    HrsH_GAS_rFPPc3               5.46796
    HrsH_GAS_rFPPc4               5.88166
    
    FPP Carbon Door Status at Fri May 30 16:05:15 EDT 2008
    HacH_DTC_VMIC1182:0_Ch13      disabled
    HacH_DTC_VMIC1182:0_Ch17      enabled
    HacH_DTC_VMIC1182:0_Ch9       disabled
    HacH_DTC_VMIC1182:0_Ch5       disabled
    
    Left S2 HV
    S2 Slot0 ch0 : -2311.8
    S2 Slot0 ch1 : -2212.3
    S2 Slot0 ch2 : -2166.4
    S2 Slot0 ch3 : -2231.2
    S2 Slot0 ch4 : -1793.8
    S2 Slot0 ch5 : -2165.8
    S2 Slot0 ch6 : -1940
    S2 Slot0 ch7 : -1876.9
    S2 Slot0 ch8 : -2030.4
    S2 Slot0 ch9 : -1889.6
    S2 Slot0 ch10 : -2094.7
    S2 Slot0 ch11 : -1867.9
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1785.2
    S1 Slot1 ch1 : -1810.5
    S1 Slot1 ch2 : -1791
    S1 Slot1 ch3 : -1817.7
    S1 Slot1 ch4 : -1699.9
    S1 Slot1 ch5 : -1856.1
    S1 Slot1 ch6 : -1916.2
    S1 Slot1 ch7 : -1700.1
    S1 Slot1 ch8 : -1961.1
    S1 Slot1 ch9 : -1746.3
    S1 Slot1 ch10 : -1799.2
    S1 Slot1 ch11 : -1708.3
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1544.3
    GCER Slot2 ch1 : -1462.1
    GCER Slot2 ch2 : -1528
    GCER Slot2 ch3 : -1453
    GCER Slot2 ch4 : -1798.1
    GCER Slot2 ch5 : -1983.6
    GCER Slot2 ch6 : -1750.5
    GCER Slot2 ch7 : -1751.9
    GCER Slot2 ch8 : -2009.9
    GCER Slot2 ch9 : -1588.6
    GCER Slot2 ch10 : -15
    GCER Slot2 ch11 : -23.6
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -860.4
    PRL1 Slot3 ch1 : -784.5
    PRL1 Slot3 ch2 : -905.8
    PRL1 Slot3 ch3 : -981.2
    PRL1 Slot3 ch4 : -730.3
    PRL1 Slot3 ch5 : -811
    PRL1 Slot3 ch6 : -1081.3
    PRL1 Slot3 ch7 : -990.8
    PRL1 Slot3 ch8 : -810.5
    PRL1 Slot3 ch9 : -790.9
    PRL1 Slot3 ch10 : -829.5
    PRL1 Slot3 ch11 : -785.3
    PRL1 Slot4 ch0 : -870.1
    PRL1 Slot4 ch1 : -900.5
    PRL1 Slot4 ch2 : -750.8
    PRL1 Slot4 ch3 : -895.9
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -822
    PRL1 Slot4 ch6 : -836
    PRL1 Slot4 ch7 : -826.4
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -991.4
    PRL1 Slot4 ch10 : -1030.9
    PRL1 Slot4 ch11 : -861.4
    PRL1 Slot5 ch0 : -1041.1
    PRL1 Slot5 ch1 : -871
    PRL1 Slot5 ch2 : -916.2
    PRL1 Slot5 ch3 : -735.8
    PRL1 Slot5 ch4 : -890.7
    PRL1 Slot5 ch5 : -810.3
    PRL1 Slot5 ch6 : -821.1
    PRL1 Slot5 ch7 : -895.6
    PRL1 Slot5 ch8 : -741.3
    PRL1 Slot5 ch9 : -841.4
    PRL1 Slot5 ch10 : -16.5
    PRL1 Slot5 ch11 : -25.6
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -920.5
    PRL2 Slot9 ch1 : -881.3
    PRL2 Slot9 ch2 : -800.1
    PRL2 Slot9 ch3 : -869.9
    PRL2 Slot9 ch4 : -810.9
    PRL2 Slot9 ch5 : -941.5
    PRL2 Slot9 ch6 : -851.5
    PRL2 Slot9 ch7 : -890.6
    PRL2 Slot9 ch8 : -811.4
    PRL2 Slot9 ch9 : -780.6
    PRL2 Slot9 ch10 : -821
    PRL2 Slot9 ch11 : -851.4
    PRL2 Slot10 ch0 : -755.7
    PRL2 Slot10 ch1 : -812.4
    PRL2 Slot10 ch2 : -871
    PRL2 Slot10 ch3 : -900.8
    PRL2 Slot10 ch4 : -881.4
    PRL2 Slot10 ch5 : -871
    PRL2 Slot10 ch6 : -815.2
    PRL2 Slot10 ch7 : -824.8
    PRL2 Slot10 ch8 : -760.3
    PRL2 Slot10 ch9 : -715.7
    PRL2 Slot10 ch10 : -911
    PRL2 Slot10 ch11 : -781.3
    PRL2 Slot11 ch0 : -1000.7
    PRL2 Slot11 ch1 : -900.4
    PRL2 Slot11 ch2 : -850.6
    PRL2 Slot11 ch3 : -1079.9
    PRL2 Slot11 ch4 : -1050.2
    PRL2 Slot11 ch5 : -800
    PRL2 Slot11 ch6 : -860.4
    PRL2 Slot11 ch7 : -1031.3
    PRL2 Slot11 ch8 : -911.3
    PRL2 Slot11 ch9 : -880.3
    PRL2 Slot11 ch10 : -12.9
    PRL2 Slot11 ch11 : -24.7
    -----
    # Map  BB_DE  Measured Voltage
      1 :    -11     -8 
      2 :    -12     -9 
      3 :    -12    -11 
      4 :    -11    -12 
      5 :    -10     -9 
      6 :     -9     -9 
      7 :     -9    -11 
      8 :    -10     -9 
      9 :    -11    -10 
     10 :    -12     -7 
     11 :     -9    -12 
     12 :    -12    -11 
     13 :    -10    -11 
     14 :    -10    -10 
     15 :    -11    -11 
     16 :    -11    -10 
     17 :    -10    -10 
     18 :    -10    -10 
     19 :     -9     -9 
     20 :    -11    -10 
     21 :    -10    -11 
     22 :    -10    -12 
     23 :    -10    -12 
     24 :    -10    -11 
    # Map  BB_DE  Measured Current
      1 :      0     -3 
      2 :     -2     -2 
      3 :      1     -0 
      4 :     -4     -1 
      5 :     -1     -1 
      6 :     -1     -3 
      7 :     -2     -1 
      8 :      1     -1 
      9 :      1     -1 
     10 :     -3     -1 
     11 :      3     -1 
     12 :     -4     -0 
     13 :     -5     -3 
     14 :      2     -0 
     15 :     -2     -2 
     16 :      0     -0 
     17 :     -2      0 
     18 :     -2     -0 
     19 :     -1     -2 
     20 :     -0     -2 
     21 :     -2     -0 
     22 :      1     -1 
     23 :     -2     -0 
     24 :      4     -1 
    # Map  BB_E  Measured Voltage
      1 :    -10  -1701 
      2 :    -11  -1475 
      3 :    -10     -4 
      4 :    -10    -12 
      5 :    -11    -11 
      6 :    -10    -13 
      7 :    -10    -12 
      8 :    -10    -10 
      9 :    -12    -13 
     10 :  -1438    -13 
     11 :  -1808    -14 
     12 :  -1229    -15 
     13 :     -1    -18 
     14 :  -1426    -18 
     15 :  -1800    -17 
     16 :     -4    -18 
     17 :  -1711    -18 
     18 :  -1251    -18 
     19 :  -1547    -17 
     20 :     -5    -17 
     21 :  -1690    -19 
     22 :  -1702    -18 
     23 :     -4    -18 
     24 :    -12    -35 
    # Map  BB_E  Measured Current
      1 :     -1   -181 
      2 :     -2   -158 
      3 :     -1      0 
      4 :      0     -1 
      5 :     -1     -1 
      6 :     -1     -3 
      7 :     -1     -2 
      8 :     -1      3 
      9 :     -1     -5 
     10 :   -154     -0 
     11 :   -192     -2 
     12 :   -129      0 
     13 :     -2     -4 
     14 :   -150     -3 
     15 :   -197     -4 
     16 :     -1     -1 
     17 :   -188     -6 
     18 :   -138     -2 
     19 :   -161     -2 
     20 :      1     -2 
     21 :   -179     -1 
     22 :   -182     -1 
     23 :     -0     -4 
     24 :     -1      2 
    # Map  BB_SC_R  Measured Voltage
      1 :     -6 
      2 :     -7 
      3 :     -7 
      4 :     -6 
      5 :     -7 
      6 :     -8 
      7 :     -4 
      8 :     -6 
      9 :     -7 
     10 :     -5 
     11 :     -6 
     12 :     -7 
     13 :     -6 
    # Map  BB_SC_R  Measured Current
      1 :     -1 
      2 :     -0 
      3 :     -1 
      4 :     -1 
      5 :     -0 
      6 :     -0 
      7 :     -2 
      8 :      0 
      9 :     -4 
     10 :      0 
     11 :     -2 
     12 :     -2 
     13 :     -2 
    # Map  BB_DC  Measured Voltage
      1 :     -1     -0     -0     -0 
      2 :      0     -0     -0     -0 
      3 :     -0      0      0      0 
    # Map  BB_DC  Measured Current
      1 :     -0     -0      0     -0 
      2 :     -0     -0     -0     -0 
      3 :     -0     -0     -0     -0 
    # Map  BB_PS_R  Measured Voltage
      1 :    -20 
      2 :    -21 
      3 :    -18 
      4 :    -21 
      5 :    -23 
      6 :    -21 
      7 :    -22 
      8 :    -22 
      9 :    -23 
     10 :    -22 
     11 :    -22 
     12 :    -23 
     13 :     -9 
     14 :     -9 
     15 :     -9 
     16 :     -9 
     17 :     -9 
     18 :     -8 
     19 :     -9 
     20 :     -9 
     21 :    -10 
     22 :     -9 
     23 :     -9 
     24 :     -9 
     25 :     -8 
     26 :     -9 
     27 :     -8 
    # Map  BB_PS_R  Measured Current
      1 :     -8 
      2 :     -2 
      3 :     -7 
      4 :     -5 
      5 :     -9 
      6 :     -2 
      7 :     -7 
      8 :     -4 
      9 :     -6 
     10 :     -4 
     11 :     -6 
     12 :     -4 
     13 :     -4 
     14 :     -2 
     15 :     -2 
     16 :     -3 
     17 :     -4 
     18 :     -2 
     19 :     -1 
     20 :     -3 
     21 :     -2 
     22 :     -2 
     23 :     -1 
     24 :     -2 
     25 :     -2 
     26 :     -2 
     27 :     -1 
    # Map  BB_SC_L  Measured Voltage
      1 :    -10 
      2 :    -10 
      3 :    -10 
      4 :    -10 
      5 :    -10 
      6 :    -10 
      7 :    -10 
      8 :     -9 
      9 :     -9 
     10 :    -10 
     11 :    -10 
     12 :    -11 
     13 :     -5 
    # Map  BB_SC_L  Measured Current
      1 :     -5 
      2 :     -6 
      3 :     -6 
      4 :     -5 
      5 :     -6 
      6 :     -6 
      7 :     -4 
      8 :     -6 
      9 :     -4 
     10 :     -5 
     11 :     -5 
     12 :     -6 
     13 :     -2 
    # Map  BB_CER  Measured Voltage
      1 :   1701   1950 
      2 :   1753   1970 
      3 :   1520   1349 
      4 :   1582   1800 
      5 :   1470   1570 
      6 :   2072   1699 
      7 :   1799   1879 
      8 :   1491   1599 
      9 :   1250   1203 
     10 :   1801   1797 
    # Map  BB_CER  Measured Current
      1 :    610    686 
      2 :    626    696 
      3 :    548    473 
      4 :    568    631 
      5 :    526    552 
      6 :    742    597 
      7 :    644    657 
      8 :    532    563 
      9 :    447    420 
     10 :    645    631 
    # Map  BB_PS_L  Measured Voltage
      1 :     -8 
      2 :     -8 
      3 :     -9 
      4 :     -9 
      5 :     -9 
      6 :     -9 
      7 :    -10 
      8 :     -9 
      9 :     -7 
     10 :     -8 
     11 :     -7 
     12 :     -8 
     13 :     -7 
     14 :     -8 
     15 :     -6 
     16 :     -7 
     17 :     -8 
     18 :     -7 
     19 :     -8 
     20 :     -8 
     21 :     -7 
     22 :     -6 
     23 :     -6 
     24 :     -6 
     25 :     -6 
     26 :     -8 
     27 :     -6 
    # Map  BB_PS_L  Measured Current
      1 :      1 
      2 :     -2 
      3 :     -2 
      4 :     -2 
      5 :     -4 
      6 :     -4 
      7 :     -1 
      8 :     -2 
      9 :     -0 
     10 :     -4 
     11 :      1 
     12 :     -2 
     13 :     -2 
     14 :     -4 
     15 :      0 
     16 :     -4 
     17 :     -1 
     18 :     -3 
     19 :     -2 
     20 :     -0 
     21 :     -2 
     22 :     -1 
     23 :     -1 
     24 :     -2 
     25 :     -0 
     26 :     -1 
     27 :     -2 
    # Map  BB_SH  Measured Voltage
      1 :    -11    -12    -12    -11    -10    -10    -10 
      2 :    -10     -9     -9    -10    -10    -11    -11 
      3 :    -10    -11    -12     -9    -10    -12    -13 
      4 :    -12    -10    -10    -11    -12    -19    -17 
      5 :    -11    -11    -10    -10    -19    -18    -18 
      6 :     -9    -11    -10    -17    -18    -20    -18 
      7 :    -10    -10    -10     -8    -19    -19    -18 
      8 :     -9    -11    -12    -11    -11    -11    -11 
      9 :     -9     -9    -11     -9    -10    -13    -11 
     10 :    -10     -7    -12    -11    -12    -12    -11 
     11 :    -11    -11    -10    -11    -12    -11     -9 
     12 :    -10    -10    -10    -12    -11    -12     -9 
     13 :     -9    -10    -11    -12    -11    -10    -12 
     14 :    -12    -11    -10    -12    -10    -10    -13 
     15 :    -11    -10    -10    -11    -12    -11     -5 
     16 :    -10    -10    -10  -1831  -1593     -7     -6 
     17 :    -12  -1438  -1808  -1229  -1630  -1624     -6 
     18 :     -1  -1426  -1800  -1189  -1871  -1612     -8 
     19 :     -4  -1711  -1251  -1547  -1315  -1843    -10 
     20 :     -5  -1690  -1702  -1470  -1542  -1571     -5 
     21 :     -4    -12  -1701  -1475  -1807     -3    -13 
     22 :     -4    -12    -11    -13    -13    -13    -14 
     23 :    -13    -12    -10    -13    -13    -15    -13 
     24 :    -13    -14    -15    -12    -14    -14    -14 
     25 :    -18    -18    -17    -18    -12    -11    -10 
     26 :    -18    -18    -17    -12    -10    -11    -10 
     27 :    -17    -19    -18    -18    -10    -12    -11 
    # Map  BB_SH  Measured Current
      1 :      0     -2      1     -4     -3     -0     -2 
      2 :     -1     -1     -2     -0      0     -0     -2 
      3 :      1      1     -3      3     -0      0     -1 
      4 :     -4     -5      2     -0     -2     -5     -5 
      5 :     -2      0     -2     -2     -4     -4     -5 
      6 :     -1     -0     -2     -4     -3     -2     -3 
      7 :      1     -2      4     -3     -4     -5     -3 
      8 :     -2     -0     -1     -2     -1     -2     -1 
      9 :     -1     -3     -1     -1      1     -0     -2 
     10 :     -1     -1     -1     -2      1      1     -2 
     11 :     -0     -3     -0     -2     -1     -2     -0 
     12 :     -0      0     -0     -0     -1     -1     -0 
     13 :     -2     -2     -0     -1     -4      2     -2 
     14 :     -0     -1     -1     -0     -4      1     -1 
     15 :     -2     -1      0     -1     -2     -2     -1 
     16 :     -1     -1     -1   -198   -170      0     -0 
     17 :     -1   -154   -192   -129   -167   -174     -0 
     18 :     -2   -150   -197   -126   -201   -179      0 
     19 :     -1   -188   -138   -161   -142   -195     -0 
     20 :      1   -179   -182   -162   -165   -163     -2 
     21 :     -0     -1   -181   -158   -192     -2     -4 
     22 :      0     -1     -1     -2     -1     -2     -2 
     23 :     -3     -2      3     -5     -2     -2     -1 
     24 :     -0     -2      0     -0     -3     -1     -0 
     25 :     -4     -3     -4     -1     -1     -0     -2 
     26 :     -6     -2     -2      0     -1      0     -2 
     27 :     -2     -1     -1     -4     -3     -2     -1 
    # Map  BB_TESTMAP  Measured Voltage
      1 :    -17    -19    -18    -18    -10    -12    -11 
      2 :    -18    -18    -17    -12    -10    -11    -10 
      3 :    -18    -18    -17    -18    -12    -11    -10 
      4 :    -13    -14    -15    -12    -14    -14    -14 
      5 :    -13    -12    -10    -13    -13    -15    -13 
      6 :     -4    -12    -11    -13    -13    -13    -14 
      7 :     -4    -12  -1701  -1475  -1807     -3    -13 
      8 :     -5  -1690  -1702  -1470  -1542  -1571     -5 
      9 :     -4  -1711  -1251  -1547  -1315  -1843    -10 
     10 :     -1  -1426  -1800  -1189  -1871  -1612     -8 
     11 :    -12  -1438  -1808  -1229  -1630  -1624     -6 
     12 :    -10    -10    -10  -1831  -1593     -7     -6 
     13 :    -11    -10    -10    -11    -12    -11     -5 
     14 :    -12    -11    -10    -12    -10    -10    -13 
     15 :     -9    -10    -11    -12    -11    -10    -12 
     16 :    -10    -10    -10    -12    -11    -12     -9 
     17 :    -11    -11    -10    -11    -12    -11     -9 
     18 :    -10     -7    -12    -11    -12    -12    -11 
     19 :     -9     -9    -11     -9    -10    -13    -11 
     20 :     -9    -11    -12    -11    -11    -11    -11 
     21 :    -10    -10    -10     -8    -19    -19    -18 
     22 :     -9    -11    -10    -17    -18    -20    -18 
     23 :    -11    -11    -10    -10    -19    -18    -18 
     24 :    -12    -10    -10    -11    -12    -19    -17 
     25 :    -10    -11    -12     -9    -10    -12    -13 
     26 :    -10     -9     -9    -10    -10    -11    -11 
     27 :    -11    -12    -12    -11    -10    -10    -10 
    # Map  BB_TESTMAP  Measured Current
      1 :     -2     -1     -1     -4     -3     -2     -1 
      2 :     -6     -2     -2      0     -1      0     -2 
      3 :     -4     -3     -4     -1     -1     -0     -2 
      4 :     -0     -2      0     -0     -3     -1     -0 
      5 :     -3     -2      3     -5     -2     -2     -1 
      6 :      0     -1     -1     -2     -1     -2     -2 
      7 :     -0     -1   -181   -158   -192     -2     -4 
      8 :      1   -179   -182   -162   -165   -163     -2 
      9 :     -1   -188   -138   -161   -142   -195     -0 
     10 :     -2   -150   -197   -126   -201   -179      0 
     11 :     -1   -154   -192   -129   -167   -174     -0 
     12 :     -1     -1     -1   -198   -170      0     -0 
     13 :     -2     -1      0     -1     -2     -2     -1 
     14 :     -0     -1     -1     -0     -4      1     -1 
     15 :     -2     -2     -0     -1     -4      2     -2 
     16 :     -0      0     -0     -0     -1     -1     -0 
     17 :     -0     -3     -0     -2     -1     -2     -0 
     18 :     -1     -1     -1     -2      1      1     -2 
     19 :     -1     -3     -1     -1      1     -0     -2 
     20 :     -2     -0     -1     -2     -1     -2     -1 
     21 :      1     -2      4     -3     -4     -5     -3 
     22 :     -1     -0     -2     -4     -3     -2     -3 
     23 :     -2      0     -2     -2     -4     -4     -5 
     24 :     -4     -5      2     -0     -2     -5     -5 
     25 :      1      1     -3      3     -0      0     -1 
     26 :     -1     -1     -2     -0      0     -0     -2 
     27 :      0     -2      1     -4     -3     -0     -2 
    Threshold for 'mwdc_back' is +7.504 V  (3072)
    Threshold for 'BB_Sh' is -0.050 V  (1976)
    Threshold for 'BB_PSh' is -0.050 V  (1976)
    Threshold for 'BB_Cer' is -0.150 V  (1761)