Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 18:09:50 on May 30, 2008

    Entry number 240434

    keyword=End_of_Run_1732
    ****************************
     Run Number: 1732
     End of Run Comment:
    Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8359,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=5000   ps2=16777215   ps3=400   ps4=5000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5007353      [+]: 2465359      [-]: 2467871      
    TIME     : [0]: 46.954 mins  [+]: 23.172 mins  [-]: 23.172 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.89149 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  41.74%      [+]:  41.81%      [-]:  41.95%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :15.0/74903.1 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :14.1/5622.8 Hz   T4[0] : 3.3/16649.6 Hz   T5[0] :3016.5/3016.5 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :15.0/74848.6 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :14.0/5616.9 Hz   T4[+] : 3.3/16635.7 Hz   T5[+] :3013.3/3013.3 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :15.0/75054.4 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :14.1/5635.8 Hz   T4[-] : 3.3/16682.5 Hz   T5[-] :3023.6/3023.6 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42203/211019640  T2[0] :      0/0        T3[0] :  39601/15840711  T4[0] :   9381/46905906  T5[0] :8498246/8498246  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  28848/2884849  
    T1[+] :  20812/104064980  T2[+] :      0/0        T3[+] :  19523/7809444  T4[+] :   4625/23129322  T5[+] :4189458/4189458  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  14237/1423708  
    T1[-] :  20869/104347921  T2[-] :      0/0        T3[-] :  19588/7835449  T4[-] :   4638/23193575  T5[-] :4203709/4203709  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  14236/1423664  
    
    AVERAGE CURRENT
    BCM x1 : 12.8738uA  BCM x3 : 12.8735uA  BCM x10: 6.4692 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1455 ppm     BCM u3 :    -1406 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1467 ppm     BCM d3 :    -1387 ppm     BCM d10:    -1401 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.03636        BCM u3 [0]:0.03636        BCM u10[0]:-5.23E-05      
    BCM u1 [+]:0.01793        BCM u3 [+]:0.01793        BCM u10[+]:-2.581E-05     
    BCM u1 [-]:0.01798        BCM u3 [-]:0.01798        BCM u10[-]:-2.58E-05      
    
    BCM d1 [0]:0.03617        BCM d3 [0]:0.03617        BCM d10[0]:0.0365         
    BCM d1 [+]:0.01784        BCM d3 [+]:0.01784        BCM d10[+]:0.018          
    BCM d1 [-]:0.01789        BCM d3 [-]:0.01789        BCM d10[-]:0.01805        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1732 at Fri May 30 18:09:40 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.835876
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00438803
    Right Arm arm angle : 0.197
    HALLA:p : 1192.29
    HALLA:dpp : -7.5596e-05
    Tiefenbach Hall A energy : 1192.29
    Left Arm Top VDC Current : -1.9043
    Left Arm Bottom VDC Current : 3.71094
    -----
    Left Arm Q1 momentum : 0.835885
    Left Arm Q1 power supply : 628.862
    Left Arm Q1 gauss meter : 0.05376
    Left Arm Q2 gauss meter : -0.18968
    Left Arm Q2 power supply current : 359.883
    Left Arm Q2 momentum : 0.835772
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 278.656
    Left Arm D1 momentum : 0.835876
    Left Arm D1 NMR : 0.352074
    Left Arm Q3 gauss meter : 0.169537
    Left Arm Q3 power supply current : 332.811
    Left Arm Q3 momentum : 0.83596
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.0045122
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -8.85e-05
    Right Arm Q2 power supply current : -0.000125711
    Right Arm Q2 momentum : -8.59125e-09
    Right Arm Q2 gauss meter : -0.000296
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0261862
    Right Arm D1 momentum : 0.00438803
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000149452
    Right Arm Q3 momentum : 0.000193664
    Right Arm Q3 gauss meter : -0.0002654
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5634
    -----
    Average current of the two cavities : 17.648
    Current on Unser monitor : 29.9932
    Current on Upstream bcm : 17.3345
    Current on Downstream bcm : 17.9615
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 110.776
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.3
    Hall A momentum orbit correction (dpp) : -6.85475e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.3
    Hall C energy (hallc_MeV) : 5710.96
    Delta(E)/E width (MV_AI_DXWID) : 1.45362
    IPM1C12.XPOS : 0.249833
    IPM1H04A.XPOS : -1.12855
    IPM1H04A.YPOS : 1.10816
    IPM1H04B.XPOS : -1.80338
    IPM1H04B.YPOS : 1.87852
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.301758
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.298828
    -----
    Right Arm Collimator : -0.00820313
    HacR_HPE1313A:0_Ch58 : -0.569336
    HacR_HPE1313A:0_Ch55 : 21.7773
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 153
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.961491
    SLI vert. size mm : 0
    SLI y position : 2.98967
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.55
    temperature loop 1(2) : 100.18
    temperature loop 1(3) : 95.56
    temperature loop 3(1) : 20.01
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.1
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0540192
    HPH H2 loop 3 : 66.8188
    -----