Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:16:27 on May 30, 2008

    Entry number 240446

    keyword=End_of_Run_1735
    ****************************
     Run Number: 1735
     End of Run Comment:
    Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8359,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=5000   ps2=16777215   ps3=400   ps4=5000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5006053      [+]: 2462625      [-]: 2469518      
    TIME     : [0]: 46.440 mins  [+]: 22.913 mins  [-]: 22.915 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.28047 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  42.38%      [+]:  42.50%      [-]:  42.52%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :15.4/76847.3 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :15.0/6001.5 Hz   T4[0] : 3.5/17559.5 Hz   T5[0] :3082.7/3082.7 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :15.4/76779.8 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :15.0/5996.7 Hz   T4[+] : 3.5/17552.4 Hz   T5[+] :3079.5/3079.5 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :15.4/76994.7 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :15.0/6012.4 Hz   T4[-] : 3.5/17582.3 Hz   T5[-] :3089.5/3089.5 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42825/214129422  T2[0] :      0/0        T3[0] :  41806/16722783  T4[0] :   9785/48928155  T5[0] :8589601/8589601  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  28533/2853300  
    T1[+] :  21111/105557331  T2[+] :      0/0        T3[+] :  20610/8244256  T4[+] :   4826/24131163  T5[+] :4233766/4233766  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  14078/1407802  
    T1[-] :  21172/105860340  T2[-] :      0/0        T3[-] :  20666/8266526  T4[-] :   4834/24173991  T5[-] :4247782/4247782  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  14079/1407902  
    
    AVERAGE CURRENT
    BCM x1 : 14.1177uA  BCM x3 : 14.1171uA  BCM x10: 7.0842 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1502 ppm     BCM u3 :    -1452 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1509 ppm     BCM d3 :    -1431 ppm     BCM d10:    -1447 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.03949        BCM u3 [0]:0.03949        BCM u10[0]:-5.174E-05     
    BCM u1 [+]:0.01947        BCM u3 [+]:0.01947        BCM u10[+]:-2.553E-05     
    BCM u1 [-]:0.01953        BCM u3 [-]:0.01953        BCM u10[-]:-2.553E-05     
    
    BCM d1 [0]:0.03918        BCM d3 [0]:0.03918        BCM d10[0]:0.03953        
    BCM d1 [+]:0.01932        BCM d3 [+]:0.01931        BCM d10[+]:0.01949        
    BCM d1 [-]:0.01938        BCM d3 [-]:0.01937        BCM d10[-]:0.01955        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1735 at Fri May 30 20:16:17 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.835875
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00437522
    Right Arm arm angle : 0.197
    HALLA:p : 1192.32
    HALLA:dpp : -5.18004e-05
    Tiefenbach Hall A energy : 1192.32
    Left Arm Top VDC Current : -0.732422
    Left Arm Bottom VDC Current : 2.7832
    -----
    Left Arm Q1 momentum : 0.835885
    Left Arm Q1 power supply : 628.862
    Left Arm Q1 gauss meter : 0.05376
    Left Arm Q2 gauss meter : -0.18964
    Left Arm Q2 power supply current : 359.881
    Left Arm Q2 momentum : 0.835766
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 278.66
    Left Arm D1 momentum : 0.835875
    Left Arm D1 NMR : 0.352074
    Left Arm Q3 gauss meter : 0.169551
    Left Arm Q3 power supply current : 332.81
    Left Arm Q3 momentum : 0.835956
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00479852
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001063
    Right Arm Q2 power supply current : -0.000258818
    Right Arm Q2 momentum : -5.24066e-07
    Right Arm Q2 gauss meter : -0.0002983
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0270546
    Right Arm D1 momentum : 0.00437522
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -1.49452e-05
    Right Arm Q3 momentum : -3.38035e-07
    Right Arm Q3 gauss meter : -0.0002659
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.5635
    -----
    Average current of the two cavities : 19.7854
    Current on Unser monitor : 29.9689
    Current on Upstream bcm : 19.5103
    Current on Downstream bcm : 20.0606
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 110.738
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.32
    Hall A momentum orbit correction (dpp) : -5.09643e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.32
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 1.45654
    IPM1C12.XPOS : 0.206502
    IPM1H04A.XPOS : -1.12674
    IPM1H04A.YPOS : 1.13626
    IPM1H04B.XPOS : -1.80193
    IPM1H04B.YPOS : 1.90639
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.301758
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.299805
    -----
    Right Arm Collimator : -0.00844727
    HacR_HPE1313A:0_Ch58 : -0.570312
    HacR_HPE1313A:0_Ch55 : 21.875
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 157
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.01242
    SLI vert. size mm : 0
    SLI y position : 0.86385
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 35.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.62
    temperature loop 1(2) : 100.25
    temperature loop 1(3) : 95.57
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.2
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 49.7129
    -----