     Run Number: 1736
     End of Run Comment:
    Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8359,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=
     
    
    PRESCALE FACTORS:ps1=5000   ps2=16777215   ps3=400   ps4=5000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5010362      [+]: 2466195      [-]: 2469908      
    TIME     : [0]: 36.895 mins  [+]: 18.208 mins  [-]: 18.207 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -6.20524 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  42.39%      [+]:  42.45%      [-]:  42.54%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :19.3/96274.7 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :18.1/7247.9 Hz   T4[0] : 4.2/21051.8 Hz   T5[0] :3887.7/3887.7 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :19.2/96139.9 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :18.1/7235.6 Hz   T4[+] : 4.2/21020.0 Hz   T5[+] :3881.5/3881.5 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :19.3/96431.4 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :18.2/7261.1 Hz   T4[-] : 4.2/21087.6 Hz   T5[-] :3894.0/3894.0 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  42624/213123221  T2[0] :      0/0        T3[0] :  40111/16044679  T4[0] :   9320/46602352  T5[0] :8606232/8606232  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  22668/2266829  
    T1[+] :  21006/105033445  T2[+] :      0/0        T3[+] :  19762/7904943  T4[+] :   4592/22964543  T5[+] :4240578/4240578  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  11187/1118727  
    T1[-] :  21069/105345509  T2[-] :      0/0        T3[-] :  19830/7932261  T4[-] :   4607/23036979  T5[-] :4253930/4253930  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  11186/1118658  
    
    AVERAGE CURRENT
    BCM x1 : 18.4431uA  BCM x3 : 18.4418uA  BCM x10: 9.2481 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1574 ppm     BCM u3 :    -1527 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1578 ppm     BCM d3 :    -1506 ppm     BCM d10:    -1523 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.04103        BCM u3 [0]:0.04103        BCM u10[0]:-4.113E-05     
    BCM u1 [+]:0.02022        BCM u3 [+]:0.02022        BCM u10[+]:-2.03E-05      
    BCM u1 [-]:0.02028        BCM u3 [-]:0.02028        BCM u10[-]:-2.029E-05     
    
    BCM d1 [0]:0.04063        BCM d3 [0]:0.04062        BCM d10[0]:0.04099        
    BCM d1 [+]:0.02002        BCM d3 [+]:0.02002        BCM d10[+]:0.0202         
    BCM d1 [-]:0.02008        BCM d3 [-]:0.02008        BCM d10[-]:0.02026        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1736 at Fri May 30 20:54:42 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.835877
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00437849
    Right Arm arm angle : 0.197
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : 0.634766
    Left Arm Bottom VDC Current : 2.58789
    -----
    Left Arm Q1 momentum : 0.835885
    Left Arm Q1 power supply : 628.862
    Left Arm Q1 gauss meter : 0.05375
    Left Arm Q2 gauss meter : -0.18964
    Left Arm Q2 power supply current : 359.883
    Left Arm Q2 momentum : 0.835771
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 278.657
    Left Arm D1 momentum : 0.835877
    Left Arm D1 NMR : 0.352074
    Left Arm Q3 gauss meter : 0.169552
    Left Arm Q3 power supply current : 332.812
    Left Arm Q3 momentum : 0.83596
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00497349
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001009
    Right Arm Q2 power supply current : -0.000133106
    Right Arm Q2 momentum : -3.09285e-07
    Right Arm Q2 gauss meter : -0.0002956
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0270723
    Right Arm D1 momentum : 0.00436268
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 5.23083e-05
    Right Arm Q3 momentum : 0.000190306
    Right Arm Q3 gauss meter : -0.000266
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5635
    -----
    Average current of the two cavities : 0.0254871
    Current on Unser monitor : 12.2863
    Current on Upstream bcm : 0.0354798
    Current on Downstream bcm : 0.0154944
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 93.0672
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 1.46203
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.301758
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : -0.299805
    -----
    Right Arm Collimator : -0.00869141
    HacR_HPE1313A:0_Ch58 : -0.569824
    HacR_HPE1313A:0_Ch55 : 21.7773
    HacR_HPE1313A:0_Ch54 : -0.847656
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 75
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.596273
    SLI vert. size mm : 0
    SLI y position : 1.11174
    -----
    Target : Dummy
    fan frequency loop 1 : 0
    fan frequency loop 3 : 35
    Encoder position : 2.0575e+07
    Target type : 2.0575e+07
    temperature loop 1(1) : 100.63
    temperature loop 1(2) : 100.26
    temperature loop 1(3) : 95.58
    temperature loop 3(1) : 19.99
    temperature loop 3(2) : 19.98
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.2
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.0669839
    HPH H2 loop 3 : 85.5024
    -----