Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:33:33 on May 30, 2008

    Entry number 240452

    keyword=End_of_Run_1738
    ****************************
     Run Number: 1738
     End of Run Comment:
    Run_type=Calibration,target_type=Carbon,beam_e0=1.192,beam_raster=off,leftarm_p=0.8359,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Pointing Test
     
    
    PRESCALE FACTORS:ps1=1360   ps2=16777215   ps3=1   ps4=670   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 284350       [+]: 139590       [-]: 140610       
    TIME     : [0]: 5.162 mins  [+]: 2.577 mins  [-]: 2.578 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.50049 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  27.23%      [+]:  28.34%      [-]:  28.26%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 9.0/12283.5 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :1234.8/1234.8 Hz   T4[0] : 9.4/6267.2 Hz   T5[0] :10.4/10.4 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] : 9.0/12281.4 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :1233.1/1233.1 Hz   T4[+] : 9.3/6262.8 Hz   T5[+] :10.3/10.3 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] : 9.1/12324.2 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :1240.6/1240.6 Hz   T4[-] : 9.4/6285.2 Hz   T5[-] :10.7/10.7 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   2797/3804747  T2[0] :      0/0        T3[0] : 382485/382485   T4[0] :   2897/1941229  T5[0] :   3233/3233     T6[0] :      0/0        T7[0] :      0/0        T8[0] :   3171/317178   
    T1[+] :   1396/1899096  T2[+] :      0/0        T3[+] : 190673/190673   T4[+] :   1445/968424   T5[+] :   1591/1591     T6[+] :      0/0        T7[+] :      0/0        T8[+] :   1583/158343   
    T1[-] :   1401/1906106  T2[-] :      0/0        T3[-] : 191882/191882   T4[-] :   1450/972100   T5[-] :   1656/1656     T6[-] :      0/0        T7[-] :      0/0        T8[-] :   1583/158376   
    
    AVERAGE CURRENT
    BCM x1 : 19.4903uA  BCM x3 : 19.4885uA  BCM x10: 9.7688 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1496 ppm     BCM u3 :    -1445 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1497 ppm     BCM d3 :    -1424 ppm     BCM d10:    -1434 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.006066       BCM u3 [0]:0.006066       BCM u10[0]:-5.752E-06     
    BCM u1 [+]:0.003028       BCM u3 [+]:0.003029       BCM u10[+]:-2.873E-06     
    BCM u1 [-]:0.003038       BCM u3 [-]:0.003038       BCM u10[-]:-2.871E-06     
    
    BCM d1 [0]:0.006008       BCM d3 [0]:0.006007       BCM d10[0]:0.006057       
    BCM d1 [+]:0.002999       BCM d3 [+]:0.002999       BCM d10[+]:0.003024       
    BCM d1 [-]:0.003009       BCM d3 [-]:0.003008       BCM d10[-]:0.003033       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1738 at Fri May 30 21:33:24 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.835877
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00438067
    Right Arm arm angle : 0.197
    HALLA:p : 1192.3
    HALLA:dpp : -7.41095e-05
    Tiefenbach Hall A energy : 1192.3
    Left Arm Top VDC Current : 2.29492
    Left Arm Bottom VDC Current : -1.70898
    -----
    Left Arm Q1 momentum : 0.835885
    Left Arm Q1 power supply : 628.862
    Left Arm Q1 gauss meter : 0.05375
    Left Arm Q2 gauss meter : -0.18966
    Left Arm Q2 power supply current : 359.885
    Left Arm Q2 momentum : 0.835775
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 278.657
    Left Arm D1 momentum : 0.835877
    Left Arm D1 NMR : 0.352074
    Left Arm Q3 gauss meter : 0.16956
    Left Arm Q3 power supply current : 332.814
    Left Arm Q3 momentum : 0.835966
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00396607
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.25e-05
    Right Arm Q2 power supply current : -0.000144198
    Right Arm Q2 momentum : -8.59125e-09
    Right Arm Q2 gauss meter : -0.0002952
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0262074
    Right Arm D1 momentum : 0.00438067
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0
    Right Arm Q3 momentum : 0.000193664
    Right Arm Q3 gauss meter : -0.0002654
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5636
    -----
    Average current of the two cavities : 21.5072
    Current on Unser monitor : 31.3127
    Current on Upstream bcm : 21.254
    Current on Downstream bcm : 21.7604
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 111.608
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.3
    Hall A momentum orbit correction (dpp) : -7.33761e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.3
    Hall C energy (hallc_MeV) : 5710.92
    Delta(E)/E width (MV_AI_DXWID) : 1.21359
    IPM1C12.XPOS : 0.288247
    IPM1H04A.XPOS : -1.13152
    IPM1H04A.YPOS : 1.1331
    IPM1H04B.XPOS : -1.80662
    IPM1H04B.YPOS : 1.90249
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.302246
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.299805
    -----
    Right Arm Collimator : -0.00869141
    HacR_HPE1313A:0_Ch58 : -0.569824
    HacR_HPE1313A:0_Ch55 : 21.8262
    HacR_HPE1313A:0_Ch54 : -0.847656
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 166
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.4087
    SLI vert. size mm : 0
    SLI y position : 1.99812
    -----
    Target : Carbon
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 9.10321e+06
    Target type : 9.10321e+06
    temperature loop 1(1) : 101
    temperature loop 1(2) : 100.63
    temperature loop 1(3) : 96.19
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.98
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.2
    Heat exchange LH2 : 20
    HPH H2 loop 1 : 0.174027
    HPH H2 loop 3 : 85.5024
    -----