Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:56:01 on May 30, 2008

    Entry number 240457

    keyword=Start_Run_1741,Run_type=Test,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8192,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Test. Shower On
    Run Timestamp:       Fri May 30 21:52:28 EDT 2008
    Beginning-of-run EPICS data for Run Number 1741 at Fri May 30 21:52:36 EDT 2008
    
    
    
    Run_type=Test
    target_type=Loop 3 LH2 6 cm
    beam_e0=1.192
    beam_raster=on
    leftarm_p=0.8192
    leftarm_theta=47
    leftarm_colli=out
    bbarm_i=700
    bbarm_theta=45.0
    bbarm_zoff=
    fppdoor_0p75=closed
    fppdoor_1p5=open
    fppdoor_3=closed
    fppdoor_6=open
    fppdoor_9=open
    comment_text=Test. Shower On
    
    
    ; BBite+HRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = BigBite Calorimeter
    ; T2 = undefined
    ; T3 = L-HRS Singles (S1.and.S2)
    ; T4 = L-HRS Efficiency (S1.or.S2)
    ; T5 = T1.AND.T3 (BigBite LHRS Coincidence)
    ; T6 = undefined
    ; T7 = BigBite Cosmics
    ; T8 = 1024 Hz pulser (Note: the CRL code puts ps8 to 100 if ps8>100 here !!)
    ; String should be one line, no spaces, ending in carriage return
    ; ps1=5000,ps2=16777215,ps3=400,ps4=5000,ps5=1,ps6=65535,ps7=65535,ps8=100
    ps1=1360,ps2=16777215,ps3=100,ps4=670,ps5=1,ps6=65535,ps7=65535,ps8=100
    
    
    
    
    
    
    Left Arm Q1 momentum : 0.819061
    Left Arm Q1 power supply : 616.258
    Left Arm Q1 gauss meter : 0.0527
    Left Arm Q2 power supply current : 352.68
    Left Arm Q2 momentum : 0.819043
    Left Arm Q2 gauss meter : -0.18589
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 272.943
    Left Arm D1 momentum : 0.819182
    Left Arm D1 NMR : 0.345037
    Left Arm Q3 power supply current : 326.09
    Left Arm Q3 momentum : 0.819076
    Left Arm Q3 gauss meter : 0.166167
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : 0.2933
    -----
    Right Arm Q1 momentum : 0.00344645
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -8.5e-05
    Right Arm Q2 power supply current : -0.000118317
    Right Arm Q2 momentum : -2.7492e-07
    Right Arm Q2 gauss meter : -0.0002956
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0263698
    Right Arm D1 momentum : 0.00439048
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 4.8572e-05
    Right Arm Q3 momentum : 0.000193104
    Right Arm Q3 gauss meter : -0.0002655
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : -0.001611
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.5635
    -----
    Left Arm Top VDC Current : 5.12695
    Left Arm Bottom VDC Current : -0.0976562
    Left Arm Top VDC voltage : 3.99121
    Left Arm Bottom VDC voltage : 3.99902
    -----
    Right Arm Top VDC Current : -1.2207
    Right Arm Bottom VDC Current : -1.07422
    Right Arm Top VDC voltage : -0.0112305
    Right Arm Bottom VDC voltage : 0
    -----
    Average current of the two cavities : 5.29662
    Current on Unser monitor : 17.1726
    Current on Upstream bcm : 5.25026
    Current on Downstream bcm : 5.34297
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 97.6555
    Hall C Current : ibcm1 --- Invalid channel name
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.34
    Hall A momentum orbit correction (dpp) : -4.08642e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.34
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 1.22346
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 1.5
    Raster Y width : 1.5
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.302246
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.299316
    Left Arm Angle Floor Angle : 47
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 46.9997
    -----
    Right Arm Arm Collimator : -0.00859375
    HacR_HPE1313A:0_Ch58 : -0.568848
    HacR_HPE1313A:0_Ch55 : 21.7773
    HacR_HPE1313A:0_Ch54 : -0.847656
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    -----
    IPM1C12.XPOS : 0.245817
    IPM1C12.YPOS : 0.323263
    IPM1H04A.XPOS : -1.12537
    IPM1H04A.YPOS : 1.18779
    IPM1H04B.XPOS : -1.8062
    IPM1H04B.YPOS : 1.95289
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 8.9165
    Laser attenuation Hall A : 103
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 2 : 0
    fan frequency loop 3 : 35.5
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 101.07
    temperature loop 1(2) : 100.68
    temperature loop 1(3) : 96.01
    Heat exchange loop 1 H2 : 91.2
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange loop 3 H2 : 20
    pressure loop He : 43.9493
    pressure loop H2 before : 29.8344
    pressure loop H2 return : 30.1915
    HPH He loop 1 : 0.0813417
    HPH H2 loop 3 : 64.7478
    ----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.28944
    SLI vert. size mm : 0
    SLI y position : 0.488263
    -----
    FPP High Voltages and Currents at Fri May 30 21:52:45 EDT 2008
    MF7b1469_7gn0gen.F            1848.7
    MF7b1469_7gn0gen.E            0.5
    MF7b1469_7gn0ch0property.F    1848.7
    MF7b1469_7gn0ch0property.E    0.02
    MF7b1469_7gn0ch1property.F    1848.7
    MF7b1469_7gn0ch1property.E    0.04
    MF7b1469_7gn0ch2property.F    1848.7
    MF7b1469_7gn0ch2property.E    0.01
    MF7b1469_7gn0ch3property.F    1848.7
    MF7b1469_7gn0ch3property.E    0.04
    MF7b1469_7gn0ch4property.F    1848.7
    MF7b1469_7gn0ch4property.E    0.01
    MF7b1469_7gn1gen.F            1849.9
    MF7b1469_7gn1gen.E            0.7
    MF7b1469_7gn1ch0property.F    1849.9
    MF7b1469_7gn1ch0property.E    0.01
    MF7b1469_7gn1ch1property.F    1849.9
    MF7b1469_7gn1ch1property.E    0.02
    MF7b1469_7gn1ch2property.F    1849.9
    MF7b1469_7gn1ch2property.E    0
    MF7b1469_7gn1ch3property.F    1849.9
    MF7b1469_7gn1ch3property.E    0.01
    MF7b1469_7gn1ch4property.F    1849.9
    MF7b1469_7gn1ch4property.E    0.03
    MF7b1469_8gn0gen.F            1849.4
    MF7b1469_8gn0gen.E            1.4
    MF7b1469_8gn0ch0property.F    1849.4
    MF7b1469_8gn0ch0property.E    0.03
    MF7b1469_8gn0ch1property.F    1849.4
    MF7b1469_8gn0ch1property.E    0.02
    MF7b1469_8gn0ch2property.F    1849.4
    MF7b1469_8gn0ch2property.E    0.02
    MF7b1469_8gn0ch3property.F    1849.4
    MF7b1469_8gn0ch3property.E    0.04
    MF7b1469_8gn0ch4property.F    1849.4
    MF7b1469_8gn0ch4property.E    0
    MF7b1469_8gn1gen.F            1849.8
    MF7b1469_8gn1gen.E            2.1
    MF7b1469_8gn1ch0property.F    1849.8
    MF7b1469_8gn1ch0property.E    0.01
    MF7b1469_8gn1ch1property.F    1849.8
    MF7b1469_8gn1ch1property.E    0.06
    MF7b1469_8gn1ch2property.F    1849.8
    MF7b1469_8gn1ch2property.E    0.02
    MF7b1469_8gn1ch3property.F    1849.8
    MF7b1469_8gn1ch3property.E    0.02
    MF7b1469_8gn1ch4property.F    1849.8
    MF7b1469_8gn1ch4property.E    0.09
    MF7b1469_8gn2gen.F            23.4
    MF7b1469_8gn2gen.E            0
    MF7b1469_8gn2ch0property.F    0
    MF7b1469_8gn2ch0property.E    0
    
    FPP Chamber Threshold voltages at Fri May 30 21:52:47 EDT 2008
    HrsH_FPP_TH1                  3.89844
    HrsH_FPP_TH2                  4.02295
    HrsH_FPP_TH3                  6.96924
    HrsH_FPP_TH4                  7.07422
    
    FPP Wire Chambers Low Voltage at Fri May 30 21:52:47 EDT 2008
    HrsH_FPP_LV11P                4.91943
    HrsH_FPP_LV11M                -5.30273
    HrsH_FPP_LV12MA               -5.29102
    HrsH_FPP_LV12MB               -5.58594
    HrsH_FPP_LV21P                5.08545
    HrsH_FPP_LV21M                -4.54688
    HrsH_FPP_LV22MA               -4.71338
    HrsH_FPP_LV22MB               -4.74268
    HrsH_FPP_LV31P                4.79932
    HrsH_FPP_LV31M                -5.104
    HrsH_FPP_LV32MA               -5.09033
    HrsH_FPP_LV32MB               -4.94727
    HrsH_FPP_LV42P                4.70752
    HrsH_FPP_LV42MA               -4.72656
    HrsH_FPP_LV42MB               -4.59717
    HrsH_FPP_LV41P                4.63135
    HrsH_FPP_LV41MA               -4.8042
    HrsH_FPP_LV41MB               -4.65771
    
    FPP Level Shifters at Fri May 30 21:52:48 EDT 2008
    HacH_DTC_HPE1313A:0_Ch48      5.0708
    HacH_DTC_HPE1313A:0_Ch50      -5.11328
    
    FPP Gas Flow at Fri May 30 21:52:48 EDT 2008
    HrsH_GAS_rFPPc1               5.46796
    HrsH_GAS_rFPPc2               3.33113
    HrsH_GAS_rFPPc3               5.47077
    HrsH_GAS_rFPPc4               5.87979
    
    FPP Carbon Door Status at Fri May 30 21:52:48 EDT 2008
    HacH_DTC_VMIC1182:0_Ch13      disabled
    HacH_DTC_VMIC1182:0_Ch17      enabled
    HacH_DTC_VMIC1182:0_Ch9       disabled
    HacH_DTC_VMIC1182:0_Ch5       disabled
    
    Left S2 HV
    S2 Slot0 ch0 : -2311
    S2 Slot0 ch1 : -2212.3
    S2 Slot0 ch2 : -2166.4
    S2 Slot0 ch3 : -2232
    S2 Slot0 ch4 : -1793.8
    S2 Slot0 ch5 : -2166.5
    S2 Slot0 ch6 : -1940.7
    S2 Slot0 ch7 : -1876.9
    S2 Slot0 ch8 : -2030.4
    S2 Slot0 ch9 : -1889.6
    S2 Slot0 ch10 : -2094.7
    S2 Slot0 ch11 : -1867.9
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1785.2
    S1 Slot1 ch1 : -1810.5
    S1 Slot1 ch2 : -1791
    S1 Slot1 ch3 : -1817.7
    S1 Slot1 ch4 : -1699.9
    S1 Slot1 ch5 : -1856.1
    S1 Slot1 ch6 : -1916.2
    S1 Slot1 ch7 : -1700.1
    S1 Slot1 ch8 : -1961.1
    S1 Slot1 ch9 : -1746.3
    S1 Slot1 ch10 : -1799.2
    S1 Slot1 ch11 : -1708.3
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1543.5
    GCER Slot2 ch1 : -1462.1
    GCER Slot2 ch2 : -1528
    GCER Slot2 ch3 : -1453
    GCER Slot2 ch4 : -1798.1
    GCER Slot2 ch5 : -1983.6
    GCER Slot2 ch6 : -1750.5
    GCER Slot2 ch7 : -1751.9
    GCER Slot2 ch8 : -2009.9
    GCER Slot2 ch9 : -1587.9
    GCER Slot2 ch10 : -15
    GCER Slot2 ch11 : -23.6
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -860.4
    PRL1 Slot3 ch1 : -784.5
    PRL1 Slot3 ch2 : -905.8
    PRL1 Slot3 ch3 : -981.2
    PRL1 Slot3 ch4 : -730.3
    PRL1 Slot3 ch5 : -811
    PRL1 Slot3 ch6 : -1081.3
    PRL1 Slot3 ch7 : -990.8
    PRL1 Slot3 ch8 : -810.5
    PRL1 Slot3 ch9 : -790.9
    PRL1 Slot3 ch10 : -829.5
    PRL1 Slot3 ch11 : -785.3
    PRL1 Slot4 ch0 : -870.8
    PRL1 Slot4 ch1 : -900.5
    PRL1 Slot4 ch2 : -750.8
    PRL1 Slot4 ch3 : -895.9
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -821.2
    PRL1 Slot4 ch6 : -836
    PRL1 Slot4 ch7 : -826.4
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -991.4
    PRL1 Slot4 ch10 : -1031.7
    PRL1 Slot4 ch11 : -861.4
    PRL1 Slot5 ch0 : -1041.1
    PRL1 Slot5 ch1 : -871
    PRL1 Slot5 ch2 : -916.2
    PRL1 Slot5 ch3 : -735.8
    PRL1 Slot5 ch4 : -890.7
    PRL1 Slot5 ch5 : -810.3
    PRL1 Slot5 ch6 : -821.1
    PRL1 Slot5 ch7 : -895.6
    PRL1 Slot5 ch8 : -741.3
    PRL1 Slot5 ch9 : -841.4
    PRL1 Slot5 ch10 : -16.5
    PRL1 Slot5 ch11 : -25.6
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -920.5
    PRL2 Slot9 ch1 : -881.3
    PRL2 Slot9 ch2 : -800.1
    PRL2 Slot9 ch3 : -869.9
    PRL2 Slot9 ch4 : -810.9
    PRL2 Slot9 ch5 : -941.5
    PRL2 Slot9 ch6 : -851.5
    PRL2 Slot9 ch7 : -890.6
    PRL2 Slot9 ch8 : -811.4
    PRL2 Slot9 ch9 : -780.6
    PRL2 Slot9 ch10 : -821
    PRL2 Slot9 ch11 : -851.4
    PRL2 Slot10 ch0 : -755.7
    PRL2 Slot10 ch1 : -812.4
    PRL2 Slot10 ch2 : -871
    PRL2 Slot10 ch3 : -900.8
    PRL2 Slot10 ch4 : -881.4
    PRL2 Slot10 ch5 : -871
    PRL2 Slot10 ch6 : -815.2
    PRL2 Slot10 ch7 : -824.8
    PRL2 Slot10 ch8 : -760.3
    PRL2 Slot10 ch9 : -715
    PRL2 Slot10 ch10 : -911
    PRL2 Slot10 ch11 : -781.3
    PRL2 Slot11 ch0 : -1000.7
    PRL2 Slot11 ch1 : -900.4
    PRL2 Slot11 ch2 : -850.6
    PRL2 Slot11 ch3 : -1079.9
    PRL2 Slot11 ch4 : -1050.2
    PRL2 Slot11 ch5 : -800
    PRL2 Slot11 ch6 : -860.4
    PRL2 Slot11 ch7 : -1031.3
    PRL2 Slot11 ch8 : -911.3
    PRL2 Slot11 ch9 : -880.3
    PRL2 Slot11 ch10 : -12.9
    PRL2 Slot11 ch11 : -24.7
    -----
    # Map  BB_DE  Measured Voltage
      1 :  -1512  -1720 
      2 :  -1633  -1533 
      3 :  -1496  -1686 
      4 :  -1876  -1861 
      5 :  -1567  -1640 
      6 :  -1662  -1660 
      7 :  -1476  -1344 
      8 :  -1546  -1675 
      9 :  -1349  -1799 
     10 :  -1802  -1470 
     11 :  -1702  -1401 
     12 :  -1281  -1564 
     13 :  -1820  -1782 
     14 :  -1343  -1696 
     15 :  -1588  -1810 
     16 :  -1612  -1521 
     17 :  -1336  -1740 
     18 :  -1646  -1468 
     19 :  -1742  -1799 
     20 :  -1575  -1777 
     21 :  -1793  -1625 
     22 :  -1717  -1862 
     23 :  -2032  -1627 
     24 :  -1558  -1284 
    # Map  BB_DE  Measured Current
      1 :   -158   -192 
      2 :   -169   -175 
      3 :   -162   -186 
      4 :   -199   -209 
      5 :   -166   -173 
      6 :   -183   -185 
      7 :   -163   -143 
      8 :   -165   -182 
      9 :   -149   -202 
     10 :   -186   -158 
     11 :   -182   -149 
     12 :   -139   -174 
     13 :   -196   -190 
     14 :   -145   -187 
     15 :   -172   -197 
     16 :   -171   -162 
     17 :   -143   -186 
     18 :   -183   -155 
     19 :   -195   -189 
     20 :   -176   -200 
     21 :   -193   -169 
     22 :   -195   -176 
     23 :   -221   -171 
     24 :   -170   -137 
    # Map  BB_E  Measured Voltage
      1 :  -1675  -1701 
      2 :  -1895  -1476 
      3 :  -1493  -1533 
      4 :  -1388  -1372 
      5 :  -1530  -1788 
      6 :  -1623  -1801 
      7 :  -1782  -1476 
      8 :  -1362  -1706 
      9 :  -1480  -1740 
     10 :  -1438  -1406 
     11 :  -1808  -1692 
     12 :  -1229  -1545 
     13 :  -1877  -1565 
     14 :  -1426  -1633 
     15 :  -1800  -1442 
     16 :  -1431  -1788 
     17 :  -1711  -1595 
     18 :  -1251  -1387 
     19 :  -1547  -1773 
     20 :  -1717  -1678 
     21 :  -1689  -1673 
     22 :  -1702  -1328 
     23 :  -1599  -1411 
     24 :  -1142     -4 
    # Map  BB_E  Measured Current
      1 :   -178   -179 
      2 :   -205   -156 
      3 :   -158   -164 
      4 :   -153   -155 
      5 :   -167   -189 
      6 :   -173   -200 
      7 :   -194   -156 
      8 :   -141   -190 
      9 :   -157   -182 
     10 :   -151   -151 
     11 :   -192   -176 
     12 :   -128   -162 
     13 :   -202   -158 
     14 :   -150   -172 
     15 :   -197   -146 
     16 :   -156   -172 
     17 :   -189   -173 
     18 :   -136   -141 
     19 :   -162   -184 
     20 :   -182   -184 
     21 :   -173   -173 
     22 :   -184   -134 
     23 :   -169   -147 
     24 :   -123     -1 
    # Map  BB_SC_R  Measured Voltage
      1 :     -6 
      2 :     -7 
      3 :     -7 
      4 :     -6 
      5 :     -7 
      6 :     -8 
      7 :     -4 
      8 :     -6 
      9 :     -7 
     10 :     -5 
     11 :     -6 
     12 :     -7 
     13 :     -6 
    # Map  BB_SC_R  Measured Current
      1 :     -2 
      2 :      0 
      3 :     -1 
      4 :     -1 
      5 :     -2 
      6 :      1 
      7 :     -2 
      8 :     -0 
      9 :     -3 
     10 :      2 
     11 :     -3 
     12 :     -1 
     13 :     -3 
    # Map  BB_DC  Measured Voltage
      1 :      0      1     -0     -1 
      2 :      0     -1      0     -0 
      3 :     -0      1     -0     -0 
    # Map  BB_DC  Measured Current
      1 :     -0     -0     -0     -0 
      2 :     -0     -0     -0     -0 
      3 :     -0     -0     -0     -0 
    # Map  BB_PS_R  Measured Voltage
      1 :    -20 
      2 :    -21 
      3 :    -18 
      4 :    -21 
      5 :    -23 
      6 :    -21 
      7 :    -22 
      8 :    -22 
      9 :    -23 
     10 :    -22 
     11 :    -22 
     12 :    -23 
     13 :     -9 
     14 :     -9 
     15 :     -9 
     16 :     -9 
     17 :     -9 
     18 :     -8 
     19 :     -9 
     20 :     -9 
     21 :    -10 
     22 :     -9 
     23 :     -9 
     24 :     -9 
     25 :     -8 
     26 :     -9 
     27 :     -8 
    # Map  BB_PS_R  Measured Current
      1 :     -4 
      2 :     -9 
      3 :     -3 
      4 :     -7 
      5 :     -4 
      6 :     -9 
      7 :     -4 
      8 :     -6 
      9 :     -4 
     10 :     -5 
     11 :     -7 
     12 :     -6 
     13 :     -4 
     14 :     -2 
     15 :     -6 
     16 :     -1 
     17 :     -3 
     18 :     -2 
     19 :     -6 
     20 :     -2 
     21 :     -3 
     22 :     -1 
     23 :     -3 
     24 :     -2 
     25 :     -3 
     26 :     -2 
     27 :     -2 
    # Map  BB_SC_L  Measured Voltage
      1 :    -10 
      2 :    -10 
      3 :    -10 
      4 :    -10 
      5 :    -10 
      6 :    -10 
      7 :    -10 
      8 :     -9 
      9 :     -9 
     10 :    -10 
     11 :    -10 
     12 :    -11 
     13 :     -5 
    # Map  BB_SC_L  Measured Current
      1 :     -5 
      2 :     -6 
      3 :     -6 
      4 :     -6 
      5 :     -8 
      6 :     -6 
      7 :     -6 
      8 :     -6 
      9 :     -5 
     10 :     -6 
     11 :     -3 
     12 :     -8 
     13 :     -2 
    # Map  BB_CER  Measured Voltage
      1 :   1698   1950 
      2 :   1752   1970 
      3 :   1519   1348 
      4 :   1582   1800 
      5 :   1469   1570 
      6 :   2072   1700 
      7 :   1800   1879 
      8 :   1491   1599 
      9 :   1248   1204 
     10 :   1801   1798 
    # Map  BB_CER  Measured Current
      1 :    607    684 
      2 :    627    691 
      3 :    548    474 
      4 :    568    629 
      5 :    526    554 
      6 :    742    593 
      7 :    643    658 
      8 :    534    560 
      9 :    445    426 
     10 :    645    627 
    # Map  BB_PS_L  Measured Voltage
      1 :     -8 
      2 :     -8 
      3 :     -9 
      4 :     -9 
      5 :     -9 
      6 :     -9 
      7 :    -10 
      8 :     -9 
      9 :     -7 
     10 :     -8 
     11 :     -7 
     12 :     -8 
     13 :     -7 
     14 :     -8 
     15 :     -6 
     16 :     -7 
     17 :     -8 
     18 :     -7 
     19 :     -8 
     20 :     -8 
     21 :     -7 
     22 :     -6 
     23 :     -6 
     24 :     -6 
     25 :     -6 
     26 :     -8 
     27 :     -6 
    # Map  BB_PS_L  Measured Current
      1 :     -3 
      2 :     -2 
      3 :     -6 
      4 :      1 
      5 :     -3 
      6 :     -1 
      7 :     -3 
      8 :     -4 
      9 :      1 
     10 :     -2 
     11 :     -2 
     12 :     -2 
     13 :     -2 
     14 :     -2 
     15 :     -1 
     16 :     -2 
     17 :     -2 
     18 :     -3 
     19 :     -2 
     20 :     -5 
     21 :     -2 
     22 :     -1 
     23 :     -2 
     24 :     -2 
     25 :     -2 
     26 :     -1 
     27 :     -2 
    # Map  BB_SH  Measured Voltage
      1 :      0      0      0      0      0      0      0 
      2 :      0     -1 # Map  BB_SH  Measured Current
      1 :   -156   -175   -160   -199   -190   -214   -161 
      2 :   -165   -182   -164   -180   -157   -154   -189 
      3 :   -164   -150   -188   -180   -179   -190   -180 
      4 :   -138   -198   -147   -192   -145   -192   -188 
      5 :   -173   -172   -149   -180   -135   -169   -173 
      6 :   -196   -176   -199   -195   -202   -166   -159 
      7 :   -191   -227   -167   -195   -196   -168   -166 
      8 :   -170   -193   -208   -138   -194   -212   -176 
      9 :   -177   -181   -145   -181   -184   -158   -181 
     10 :   -201   -158   -150   -147   -161   -155   -181 
     11 :   -173   -190   -186   -197   -153   -174   -145 
     12 :   -158   -184   -157   -176   -168   -188   -189 
     13 :   -189   -195   -171   -175   -146   -185   -188 
     14 :   -173   -136   -172   -161   -184   -166   -186 
     15 :   -208   -157   -156   -163   -185   -188   -179 
     16 :   -174   -187   -146   -195   -169   -187   -148 
     17 :   -159   -152   -191   -131   -167   -172   -187 
     18 :   -204   -149   -199   -126   -206   -177   -163 
     19 :   -152   -189   -135   -165   -140   -195   -141 
     20 :   -183   -177   -182   -161   -161   -164   -179 
     21 :   -169   -121   -182   -155   -190   -148   -151 
     22 :   -170   -150   -193   -169   -194   -186   -182 
     23 :   -198   -166   -182   -184   -194   -149   -159 
     24 :   -148   -183   -161   -183   -155   -180   -144 
     25 :   -161   -166   -147   -171   -165   -156   -186 
     26 :   -175   -142   -185   -158   -154   -193   -171 
     27 :   -184   -175   -135   -147   -150   -174   -180 
    # Map  BB_TESTMAP  Measured Voltage
      1 :  -1678  -1672  -1329  -1411  -1449  -1633  -1637 
      2 :  -1595  -1387  -1770  -1473  -1452  -1750  -1628 
      3 :  -1565  -1633  -1443  -1788  -1526  -1500  -1736 
      4 :  -1406  -1692  -1545  -1684  -1473  -1692  -1346 
      5 :  -1801  -1476  -1706  -1740  -1841  -1357  -1519 
      6 :  -1533  -1372  -1788  -1583  -1800  -1745  -1634 
      7 :  -1599  -1142  -1701  -1476  -1807  -1402  -1419 
      8 :  -1717  -1689  -1702  -1470  -1542  -1571  -1683 
      9 :  -1431  -1711  -1251  -1547  -1315  -1843  -1330 
     10 :  -1877  -1426  -1800  -1189  -1871  -1612  -1544 
     11 :  -1480  -1438  -1808  -1229  -1630  -1624  -1752 
     12 :  -1623  -1782  -1362  -1831  -1594  -1768  -1393 
     13 :  -1895  -1493  -1388  -1530  -1747  -1700  -1680 
     14 :  -1627  -1284  -1675  -1519  -1727  -1530  -1765 
     15 :  -1799  -1777  -1625  -1862  -1397  -1755  -1791 
     16 :  -1521  -1740  -1468  -1669  -1597  -1756  -1758 
     17 :  -1564  -1782  -1696  -1810  -1406  -1633  -1353 
     18 :  -1799  -1470  -1401  -1346  -1470  -1467  -1719 
     19 :  -1640  -1660  -1344  -1675  -1677  -1479  -1712 
     20 :  -1533  -1686  -1861  -1269  -1825  -1936  -1640 
     21 :  -1717  -2032  -1558  -1720  -1859  -1630  -1576 
     22 :  -1742  -1575  -1793  -1852  -1915  -1628  -1468 
     23 :  -1588  -1612  -1336  -1646  -1454  -1583  -1706 
     24 :  -1281  -1820  -1343  -1823  -1360  -1896  -1758 
     25 :  -1546  -1349  -1802  -1702  -1675  -1785  -1722 
     26 :  -1567  -1662  -1476  -1690  -1529  -1439  -1744 
     27 :  -1512  -1633  -1496  -1876  -1822  -1979  -1519 
    # Map  BB_TESTMAP  Measured Current
      1 :   -184   -175   -135   -147   -150   -174   -180 
      2 :   -175   -142   -185   -158   -154   -193   -171 
      3 :   -161   -166   -147   -171   -165   -156   -186 
      4 :   -148   -183   -161   -183   -155   -180   -144 
      5 :   -198   -166   -182   -184   -194   -149   -159 
      6 :   -170   -150   -193   -169   -194   -186   -182 
      7 :   -169   -121   -182   -155   -190   -148   -151 
      8 :   -183   -177   -182   -161   -161   -164   -179 
      9 :   -152   -189   -135   -165   -140   -195   -141 
     10 :   -204   -149   -199   -126   -206   -177   -163 
     11 :   -159   -152   -191   -131   -167   -172   -187 
     12 :   -174   -187   -146   -195   -169   -187   -148 
     13 :   -208   -157   -156   -163   -185   -188   -179 
     14 :   -173   -136   -172   -159   -186   -168   -186 
     15 :   -189   -195   -171   -175   -147   -185   -188 
     16 :   -158   -184   -157   -177   -168   -185   -187 
     17 :   -173   -190   -186   -197   -153   -171   -147 
     18 :   -201   -158   -150   -147   -161   -155   -181 
     19 :   -177   -181   -145   -181   -184   -158   -181 
     20 :   -170   -193   -208   -138   -194   -212   -176 
     21 :   -191   -227   -167   -195   -196   -168   -166 
     22 :   -196   -176   -199   -195   -202   -166   -159 
     23 :   -173   -172   -149   -180   -135   -169   -173 
     24 :   -138   -198   -147   -192   -145   -192   -188 
     25 :   -164   -150   -188   -180   -179   -190   -180 
     26 :   -165   -182   -164   -180   -157   -154   -189 
     27 :   -156   -175   -160   -199   -190   -214   -161 
    Threshold for 'mwdc_back' is +7.504 V  (3072)
    Threshold for 'BB_Sh' is -0.050 V  (1976)
    Threshold for 'BB_PSh' is -0.050 V  (1976)
    Threshold for 'BB_Cer' is -0.100 V  (1864)