Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 22:51:14 on May 30, 2008

    Entry number 240464

    keyword=End_of_Run_1742
    ****************************
     Run Number: 1742
     End of Run Comment:
    Run_type=Calibration,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8192,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Calibration. Shower On
     
    
    PRESCALE FACTORS:ps1=5000   ps2=16777215   ps3=400   ps4=5000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5004974      [+]: 2464476      [-]: 2466416      
    TIME     : [0]: 46.457 mins  [+]: 22.932 mins  [-]: 22.933 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -8.48611 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  41.72%      [+]:  41.83%      [-]:  41.94%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :16.4/81752.9 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :16.1/6421.5 Hz   T4[0] : 3.7/18446.5 Hz   T5[0] :3043.2/3043.2 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :16.3/81697.5 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :16.0/6416.2 Hz   T4[+] : 3.7/18436.5 Hz   T5[+] :3041.5/3041.5 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :16.4/81940.6 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :16.1/6436.6 Hz   T4[-] : 3.7/18481.9 Hz   T5[-] :3049.6/3049.6 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  45576/227880121  T2[0] :      0/0        T3[0] :  44748/17899390  T4[0] :  10283/51418325  T5[0] :8482791/8482791  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  28543/2854324  
    T1[+] :  22481/112407085  T2[+] :      0/0        T3[+] :  22070/8828035  T4[+] :   5073/25366666  T5[+] :4184813/4184813  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  14089/1408916  
    T1[-] :  22549/112749167  T2[-] :      0/0        T3[-] :  22141/8856731  T4[-] :   5086/25430800  T5[-] :4196227/4196227  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  14090/1409011  
    
    AVERAGE CURRENT
    BCM x1 : 14.3796uA  BCM x3 : 14.3785uA  BCM x10: 7.2162 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1561 ppm     BCM u3 :    -1510 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1569 ppm     BCM d3 :    -1490 ppm     BCM d10:    -1504 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.04023        BCM u3 [0]:0.04023        BCM u10[0]:-5.186E-05     
    BCM u1 [+]:0.01985        BCM u3 [+]:0.01985        BCM u10[+]:-2.56E-05      
    BCM u1 [-]:0.01991        BCM u3 [-]:0.01991        BCM u10[-]:-2.56E-05      
    
    BCM d1 [0]:0.03993        BCM d3 [0]:0.03992        BCM d10[0]:0.04028        
    BCM d1 [+]:0.0197         BCM d3 [+]:0.0197         BCM d10[+]:0.01987        
    BCM d1 [-]:0.01976        BCM d3 [-]:0.01976        BCM d10[-]:0.01994        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1742 at Fri May 30 22:51:04 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.819181
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00437222
    Right Arm arm angle : 0.197
    HALLA:p : 1192.31
    HALLA:dpp : -6.10981e-05
    Tiefenbach Hall A energy : 1192.31
    Left Arm Top VDC Current : 3.90625
    Left Arm Bottom VDC Current : 3.61328
    -----
    Left Arm Q1 momentum : 0.819061
    Left Arm Q1 power supply : 616.205
    Left Arm Q1 gauss meter : 0.05269
    Left Arm Q2 gauss meter : -0.18587
    Left Arm Q2 power supply current : 352.681
    Left Arm Q2 momentum : 0.819047
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 272.94
    Left Arm D1 momentum : 0.819181
    Left Arm D1 NMR : 0.345037
    Left Arm Q3 gauss meter : 0.166169
    Left Arm Q3 power supply current : 326.092
    Left Arm Q3 momentum : 0.819082
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00478791
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001148
    Right Arm Q2 power supply current : -9.61322e-05
    Right Arm Q2 momentum : -2.23373e-07
    Right Arm Q2 gauss meter : -0.0002898
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0270723
    Right Arm D1 momentum : 0.00437222
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 1.12089e-05
    Right Arm Q3 momentum : 0.000188627
    Right Arm Q3 gauss meter : -0.0002661
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.619
    BigBite Gaussmeter readback : 0.5635
    -----
    Average current of the two cavities : 21.8214
    Current on Unser monitor : 31.4947
    Current on Upstream bcm : 21.5378
    Current on Downstream bcm : 22.1051
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 112.136
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.31
    Hall A momentum orbit correction (dpp) : -6.11102e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.31
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 1.23416
    IPM1C12.XPOS : 0.261062
    IPM1H04A.XPOS : -1.13131
    IPM1H04A.YPOS : 1.09928
    IPM1H04B.XPOS : -1.80141
    IPM1H04B.YPOS : 1.89934
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.302246
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.300293
    -----
    Right Arm Collimator : -0.00864258
    HacR_HPE1313A:0_Ch58 : -0.569336
    HacR_HPE1313A:0_Ch55 : 21.7285
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 171
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.11056
    SLI vert. size mm : 0
    SLI y position : 1.50986
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.88
    temperature loop 1(2) : 100.51
    temperature loop 1(3) : 95.79
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.2
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0234836
    HPH H2 loop 3 : 60.3064
    -----