    keyword=End_of_Run_1746
    ****************************
     Run Number: 1746
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8192,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Production. Kine 7, delta=+2 PS3=430
     
    
    PRESCALE FACTORS:ps1=5000   ps2=16777215   ps3=430   ps4=5000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5008617      [+]: 2463813      [-]: 2470746      
    TIME     : [0]: 37.695 mins  [+]: 18.609 mins  [-]: 18.613 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.33320 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  42.63%      [+]:  42.74%      [-]:  42.80%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :20.5/102443.0 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :18.7/8027.3 Hz   T4[0] : 4.5/22686.2 Hz   T5[0] :3816.0/3816.0 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :20.5/102305.3 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :18.6/8014.8 Hz   T4[+] : 4.5/22664.8 Hz   T5[+] :3810.3/3810.3 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :20.5/102636.2 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :18.7/8045.0 Hz   T4[-] : 4.5/22720.3 Hz   T5[-] :3824.0/3824.0 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  46338/231694695  T2[0] :      0/0        T3[0] :  42221/18155296  T4[0] :  10261/51309328  T5[0] :8630612/8630612  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  23159/2315974  
    T1[+] :  22845/114225597  T2[+] :      0/0        T3[+] :  20810/8948684  T4[+] :   5061/25305663  T5[+] :4254222/4254222  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  11433/1143313  
    T1[-] :  22924/114621744  T2[-] :      0/0        T3[-] :  20894/8984494  T4[-] :   5074/25373548  T5[-] :4270567/4270567  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  11435/1143580  
    
    AVERAGE CURRENT
    BCM x1 : 18.8372uA  BCM x3 : 18.8363uA  BCM x10: 9.4469 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1524 ppm     BCM u3 :    -1476 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1531 ppm     BCM d3 :    -1456 ppm     BCM d10:    -1469 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.04279        BCM u3 [0]:0.0428         BCM u10[0]:-4.205E-05     
    BCM u1 [+]:0.0211         BCM u3 [+]:0.0211         BCM u10[+]:-2.076E-05     
    BCM u1 [-]:0.02117        BCM u3 [-]:0.02117        BCM u10[-]:-2.076E-05     
    
    BCM d1 [0]:0.04241        BCM d3 [0]:0.04241        BCM d10[0]:0.04277        
    BCM d1 [+]:0.02091        BCM d3 [+]:0.02091        BCM d10[+]:0.02109        
    BCM d1 [-]:0.02098        BCM d3 [-]:0.02098        BCM d10[-]:0.02116        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1746 at Sat May 31 03:23:04 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.819182
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00439702
    Right Arm arm angle : 0.197
    HALLA:p : 1192.32
    HALLA:dpp : -4.68709e-05
    Tiefenbach Hall A energy : 1192.33
    Left Arm Top VDC Current : 2.34375
    Left Arm Bottom VDC Current : 2.09961
    -----
    Left Arm Q1 momentum : 0.819131
    Left Arm Q1 power supply : 616.258
    Left Arm Q1 gauss meter : 0.05271
    Left Arm Q2 gauss meter : -0.18587
    Left Arm Q2 power supply current : 352.678
    Left Arm Q2 momentum : 0.819039
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 272.944
    Left Arm D1 momentum : 0.819182
    Left Arm D1 NMR : 0.345037
    Left Arm Q3 gauss meter : 0.166169
    Left Arm Q3 power supply current : 326.088
    Left Arm Q3 momentum : 0.819074
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00460764
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.25e-05
    Right Arm Q2 power supply current : -0.000177475
    Right Arm Q2 momentum : -5.58431e-07
    Right Arm Q2 gauss meter : -0.0002928
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0268075
    Right Arm D1 momentum : 0.00439702
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 0.000104617
    Right Arm Q3 momentum : 0.000191985
    Right Arm Q3 gauss meter : -0.0002656
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5636
    -----
    Average current of the two cavities : 21.2931
    Current on Unser monitor : 31.83
    Current on Upstream bcm : 20.8161
    Current on Downstream bcm : 21.7701
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 97.4982
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.33
    Hall A momentum orbit correction (dpp) : -4.66259e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.33
    Hall C energy (hallc_MeV) : 5710.96
    Delta(E)/E width (MV_AI_DXWID) : 1.2017
    IPM1C12.XPOS : 0.194074
    IPM1H04A.XPOS : -1.12807
    IPM1H04A.YPOS : 1.10803
    IPM1H04B.XPOS : -1.79678
    IPM1H04B.YPOS : 1.87211
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.302734
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : -0.300293
    -----
    Right Arm Collimator : -0.00839844
    HacR_HPE1313A:0_Ch58 : -0.569824
    HacR_HPE1313A:0_Ch55 : 21.8262
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 168
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.469565
    SLI vert. size mm : 0
    SLI y position : 2.59906
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.67
    temperature loop 1(2) : 100.29
    temperature loop 1(3) : 95.49
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.1
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0970926
    HPH H2 loop 3 : 51.5296
    -----