Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 08:05:49 on May 31, 2008

    Entry number 240514

    keyword=End_of_Run_1752
    ****************************
     Run Number: 1752
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.8192,leftarm_theta=47,leftarm_colli=out,bbarm_i=700,bbarm_theta=45.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=Production. Kine 7, delta=+2 PS3=430
     
    
    PRESCALE FACTORS:ps1=5000   ps2=16777215   ps3=430   ps4=5000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5004251      [+]: 2462649      [-]: 2467670      
    TIME     : [0]: 80.466 mins  [+]: 39.673 mins  [-]: 39.670 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -8.77654 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  42.03%      [+]:  42.08%      [-]:  42.21%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 9.5/47366.8 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 8.6/3717.1 Hz   T4[0] : 2.3/11275.6 Hz   T5[0] :1762.0/1762.0 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] : 9.5/47340.6 Hz   T2[+] : 0.0/0.0  Hz   T3[+] : 8.6/3713.2 Hz   T4[+] : 2.3/11270.6 Hz   T5[+] :1760.2/1760.2 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] : 9.5/47503.8 Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 8.7/3729.6 Hz   T4[-] : 2.3/11302.6 Hz   T5[-] :1767.9/1767.9 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  45737/228685037  T2[0] :      0/0        T3[0] :  41734/17945844  T4[0] :  10887/54438423  T5[0] :8506710/8506710  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  49438/4943835  
    T1[+] :  22537/112687203  T2[+] :      0/0        T3[+] :  20555/8838658  T4[+] :   5365/26827938  T5[+] :4189857/4189857  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  24374/2437481  
    T1[-] :  22613/113069323  T2[-] :      0/0        T3[-] :  20644/8877234  T4[-] :   5380/26902650  T5[-] :4208074/4208074  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  24373/2437344  
    
    AVERAGE CURRENT
    BCM x1 : 8.9654 uA  BCM x3 : 8.9648 uA  BCM x10: 4.4889 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1775 ppm     BCM u3 :    -1708 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1783 ppm     BCM d3 :    -1685 ppm     BCM d10:    -1692 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0435         BCM u3 [0]:0.0435         BCM u10[0]:-8.979E-05     
    BCM u1 [+]:0.02143        BCM u3 [+]:0.02143        BCM u10[+]:-4.427E-05     
    BCM u1 [-]:0.02151        BCM u3 [-]:0.02151        BCM u10[-]:-4.427E-05     
    
    BCM d1 [0]:0.04307        BCM d3 [0]:0.04307        BCM d10[0]:0.04343        
    BCM d1 [+]:0.02122        BCM d3 [+]:0.02122        BCM d10[+]:0.0214         
    BCM d1 [-]:0.0213         BCM d3 [-]:0.02129        BCM d10[-]:0.02147        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1752 at Sat May 31 08:05:39 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.819184
    Left Arm arm angle : 46.9997
    Right Arm D1 momentum : 0.00439702
    Right Arm arm angle : 0.197
    HALLA:p : 1192.34
    HALLA:dpp : -3.82313e-05
    Tiefenbach Hall A energy : 1192.34
    Left Arm Top VDC Current : 2.68555
    Left Arm Bottom VDC Current : -2.05078
    -----
    Left Arm Q1 momentum : 0.819131
    Left Arm Q1 power supply : 616.258
    Left Arm Q1 gauss meter : 0.0527
    Left Arm Q2 gauss meter : -0.18585
    Left Arm Q2 power supply current : 352.677
    Left Arm Q2 momentum : 0.819037
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 272.944
    Left Arm D1 momentum : 0.819184
    Left Arm D1 NMR : 0.345038
    Left Arm Q3 gauss meter : 0.166163
    Left Arm Q3 power supply current : 326.086
    Left Arm Q3 momentum : 0.819067
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00331919
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -9.33e-05
    Right Arm Q2 power supply current : -0.000114619
    Right Arm Q2 momentum : -2.66329e-07
    Right Arm Q2 gauss meter : -0.0003035
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0268287
    Right Arm D1 momentum : 0.00440902
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -0.000168134
    Right Arm Q3 momentum : -4.22543e-07
    Right Arm Q3 gauss meter : -0.000266
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5636
    -----
    Average current of the two cavities : 21.5869
    Current on Unser monitor : 32.6188
    Current on Upstream bcm : 21.2746
    Current on Downstream bcm : 21.8991
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 97.5319
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.34
    Hall A momentum orbit correction (dpp) : -3.85796e-05
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.33
    Hall C energy (hallc_MeV) : 5710.95
    Delta(E)/E width (MV_AI_DXWID) : 1.21875
    IPM1C12.XPOS : 0.169045
    IPM1H04A.XPOS : -1.1227
    IPM1H04A.YPOS : 1.13397
    IPM1H04B.XPOS : -1.79311
    IPM1H04B.YPOS : 1.90271
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.301758
    HacL_HPE1313A:0_Ch55 : 23.1445
    HacL_HPE1313A:0_Ch54 : -0.300293
    -----
    Right Arm Collimator : -0.00874023
    HacR_HPE1313A:0_Ch58 : -0.569336
    HacR_HPE1313A:0_Ch55 : 21.7773
    HacR_HPE1313A:0_Ch54 : -0.848145
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 174
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.72919
    SLI vert. size mm : 0
    SLI y position : 3.20751
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.7
    temperature loop 1(2) : 100.32
    temperature loop 1(3) : 95.54
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.1
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0540192
    HPH H2 loop 3 : 72.7911
    -----