Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 13:57:11 on May 31, 2008

    Entry number 240549

    keyword=End_of_Run_1761
    ****************************
     Run Number: 1761
     End of Run Comment:
    Run_type=Production,target_type=Loop 3 LH2 6 cm,beam_e0=1.192,beam_raster=on,leftarm_p=0.9313,leftarm_theta=43.5,leftarm_colli=out,bbarm_i=700,bbarm_theta=50.0,bbarm_zoff=,fppdoor_0p75=closed,fppdoor_1p5=open,fppdoor_3=closed,fppdoor_6=open,fppdoor_9=open,comment_text=kin 8 delta -2
     
    
    PRESCALE FACTORS:ps1=4000   ps2=16777215   ps3=200   ps4=2000   ps5=1   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [0]: 5002914      [+]: 2461509      [-]: 2466983      
    TIME     : [0]: 61.985 mins  [+]: 30.572 mins  [-]: 30.569 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -8.05191 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  27.08%      [+]:  27.15%      [-]:  27.22%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :17.2/68618.6 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :17.6/3523.7 Hz   T4[0] : 8.2/16322.8 Hz   T5[0] :1801.2/1801.2 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :17.1/68493.3 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :17.6/3517.2 Hz   T4[+] : 8.2/16303.8 Hz   T5[+] :1798.5/1798.5 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :17.2/68773.8 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :17.7/3531.1 Hz   T4[-] : 8.2/16348.8 Hz   T5[-] :1804.4/1804.4 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  63799/255199938  T2[0] :      0/0        T3[0] :  65524/13104852  T4[0] :  30353/60706284  T5[0] :6698953/6698953  T6[0] :      0/0        T7[0] :      0/0        T8[0] :  38083/3808365  
    T1[+] :  31409/125638061  T2[+] :      0/0        T3[+] :  32258/6451624  T4[+] :  14953/29906198  T5[+] :3299046/3299046  T6[+] :      0/0        T7[+] :      0/0        T8[+] :  18783/1878335  
    T1[-] :  31535/126141598  T2[-] :      0/0        T3[-] :  32382/6476535  T4[-] :  14993/29986240  T5[-] :3309457/3309457  T6[-] :      0/0        T7[-] :      0/0        T8[-] :  18781/1878171  
    
    AVERAGE CURRENT
    BCM x1 : 17.6705uA  BCM x3 : 17.6695uA  BCM x10: 8.8627 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1886 ppm     BCM u3 :    -1830 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -1891 ppm     BCM d3 :    -1805 ppm     BCM d10:    -1819 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.06599        BCM u3 [0]:0.06599        BCM u10[0]:-6.918E-05     
    BCM u1 [+]:0.03249        BCM u3 [+]:0.0325         BCM u10[+]:-3.412E-05     
    BCM u1 [-]:0.03261        BCM u3 [-]:0.03261        BCM u10[-]:-3.412E-05     
    
    BCM d1 [0]:0.06545        BCM d3 [0]:0.06544        BCM d10[0]:0.06599        
    BCM d1 [+]:0.03223        BCM d3 [+]:0.03222        BCM d10[+]:0.0325         
    BCM d1 [-]:0.03235        BCM d3 [-]:0.03234        BCM d10[-]:0.03261        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1761 at Sat May 31 13:57:02 EDT 2008
    
    Wien angle : -13.5361
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.931329
    Left Arm arm angle : 43.4997
    Right Arm D1 momentum : 0.0043744
    Right Arm arm angle : 0.197
    HALLA:p : 1192.13
    HALLA:dpp : -0.000216645
    Tiefenbach Hall A energy : 1192.13
    Left Arm Top VDC Current : 4.10156
    Left Arm Bottom VDC Current : 3.80859
    -----
    Left Arm Q1 momentum : 0.931435
    Left Arm Q1 power supply : 700.748
    Left Arm Q1 gauss meter : 0.05981
    Left Arm Q2 gauss meter : -0.2111
    Left Arm Q2 power supply current : 401.056
    Left Arm Q2 momentum : 0.931388
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 310.711
    Left Arm D1 momentum : 0.931329
    Left Arm D1 NMR : 0.392307
    Left Arm Q3 gauss meter : 0.188677
    Left Arm Q3 power supply current : 370.703
    Left Arm Q3 momentum : 0.931138
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00529162
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001198
    Right Arm Q2 power supply current : 7.39479e-06
    Right Arm Q2 momentum : -3.69424e-07
    Right Arm Q2 gauss meter : -0.000302
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 0.0263133
    Right Arm D1 momentum : 0.00438258
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 5.60446e-05
    Right Arm Q3 momentum : 0.000189186
    Right Arm Q3 gauss meter : -0.0002662
    Right Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 700
    BigBite magnet current readback : 696.603
    BigBite Gaussmeter readback : 0.5636
    -----
    Average current of the two cavities : 21.1849
    Current on Unser monitor : 32.3305
    Current on Upstream bcm : 20.8449
    Current on Downstream bcm : 21.5249
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 92.693
    Hall C Current : ibcm1 --- Invalid channel name
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.12
    Hall A momentum orbit correction (dpp) : -0.000224446
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.12
    Hall C energy (hallc_MeV) : 5710.96
    Delta(E)/E width (MV_AI_DXWID) : 1.21638
    IPM1C12.XPOS : 0.868724
    IPM1H04A.XPOS : -1.12734
    IPM1H04A.YPOS : 1.14685
    IPM1H04B.XPOS : -1.7943
    IPM1H04B.YPOS : 1.91351
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.248535
    HacL_HPE1313A:0_Ch55 : 23.3398
    HacL_HPE1313A:0_Ch54 : -0.25
    -----
    Right Arm Collimator : -0.00800781
    HacR_HPE1313A:0_Ch58 : -0.569336
    HacR_HPE1313A:0_Ch55 : 21.875
    HacR_HPE1313A:0_Ch54 : -0.847168
    -----
    Wien angle : -13.5361
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -315.67
    Wien field : 8.9165
    Laser attenuation Hall A : 182
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.730435
    SLI vert. size mm : 0
    SLI y position : 0.969014
    -----
    Target : L3 6cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 2.06493e+07
    Target type : 2.06493e+07
    temperature loop 1(1) : 100.76
    temperature loop 1(2) : 100.38
    temperature loop 1(3) : 95.51
    temperature loop 3(1) : 20
    temperature loop 3(2) : 19.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 91.1
    Heat exchange LH2 : 20.1
    HPH H2 loop 1 : 0.0813417
    HPH H2 loop 3 : 53.0065
    -----